11018M MR

Publication C2.10.1 10/06

www.lincolnelectric.com

STICK

Basic, Low Hydrogen, Low Alloy Steel SMAW Electrode

(AWS E11018M-H4R)

Excalibur

®

11018M MR

is designed primarily for joining high strength steel types in the as-

welded or stress relieved conditions with excellent low temperature impact properties and
robust welding procedures. All-position welding, except vertical down.

Advantage Lincoln

Integrated Silicate Technology™

Increased moisture resistance and decreased coating fragility.

Easy Strike™ Tip

Consistent, smooth arc starts.

Square Burn-Off

Focused arc for hard to access welds.

X-Ray Quality

Demanding applications.

Hermetically Sealed Packaging – Easy Open Cans

Delivers quality product, performance reliability and
consistent results.

ISO 9001 and 14001 Certified

Manufactured to standards for environmental and quality
management systems.

Welding Positions

Conformance

AWS A5.5/A5.5M:2006

E11018M-H4R / E7618M-H4R

ASME SFA 5.5:1996

E11018M-H4R

CSA W48-01:

E7618-M-H4

DIAMETERS / LENGTH / PACKAGING

Diameter

Length

10 Lb. (4.5 kg)

50 Lb. (22.7 kg)

in. (mm)

in. (mm)

Easy Open Can

Easy Open Can

3/32 (2.4)

14 (350)

ED031972

ED031975

1/8 (3.2)

14 (350)

ED031973

ED031976

5/32 (4.0)

14 (350)

ED031974

ED031977

3/16 (4.8)

14 (350)

ED031978

1G

2F

2G

3G

4G

%C

%Mn

%Si

%P

%S

%Ni

%Cr

%Mo

%V

Requirements

0.10 max

1.30 - 1.80

0.6 max

0.030 max

0.030 max

1.25 - 2.50

0.40 max

0.25 - 0.50

0.05 max

AWS E11018M-H4R

Test Results

0.04 - 0.05

1.55 - 1.80

0.40 - 0.55

0.010 - 0.030

0.005 - 0.020

1.90 - 2.50

0.02 - 0.15

0.35 - 0.50

0.005 - 0.015

DEPOSIT COMPOSITION – As required per AWS A5.5/A5.5M:2006

Charpy V-Notch

Diffusible

Tensile Strength

Yield Strength

Elongation

ft*lbf (Joules)

Hydrogen

psi (MPa)

psi (MPa)

%

@-60°F (-50°C)

ml/100g

Requirements

110 (760)

98 - 110

20

20 (27)

4

AWS E11018M-H4R

min.

(680 - 760)

Test Results

111 - 117

100 - 110

20-25

40 - 65

1-4

As-welded

(765 - 807)

(690 - 758)

(54 - 88)

MECHANICAL PROPERTIES – As Required per AWS A5.5/A5.5M:2006

TYPICAL OPERATING PROCEDURES

Polarity

Current Range (Amps)

3/32 in.

1/8 in.

5/32 in.

3/16 in.

(2.4 mm)

(3.2 mm)

(4.0 mm)

(4.8 mm)

DC+

70-110

90-160

130-210

180-300

Typical Applications

• Certain Weldable Quenched & Tempered Steels, such as

- T1, A514, A517 and A709

• General Fabrication Requiring E11018-G or E11018M

Electrode Classification.

1F

6G

5G

4F

3F