Lightolier LUPS Series - Manual

Lightolier LUPS Series

Lightolier LUPS Series – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
Page: / 2
Loading the manual

LUPS Series Uninterruptible Power Supplies

LUPS

Page 1 of 2

550 - 1,500 VA Sine Wave UPS System

Job Information

Type:

Job Name:
Cat. No.:

Lamp(s):
Notes:

Lightolier

a Genlyte Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2006 Genlyte Group LLC (Lightolier Division) • C0406

Overall Characteristics

• 83% throughput efficiency
• Single conversion UPS, No transfer time
• Operating temperature range of 32°F (0°C) to 104°F (40°C); 65°F (19°C) to

85°F (29°C) maximum for batteries

• Standard 90 minutes of operating time
• Full-time, isolating transformer
• Variable Range Regulator allows wider range of acceptable input voltage

variation

• ANSI/IEEE C62.41 category A & B surge voltage withstand capability

Housing

• Free standing, NEMA 1 enclosure with locking doors
• Acid resistant powder coat finish
• Multiple conduit entries

Standard Metering/Controls

• AC input and output voltage
• AC input breaker
• AC output breaker
• Battery disconnect device
• Automatic battery monitor with alarm
• LED indicating lamps for system on, system on battery, low battery warning

Battery

Maintenance free, sealed lead calcium battery has an estimated service life of
10 years, and operating temperature range of 65°F (19°C) to 85°F (30°C)*.

* Increases or decreases in temperature will affect battery performance. Optimum battery performance
realized at 77°F (25°C). Batteries are rated at 100% capacity at 77°F (25°C).

Electronics

Input

• Input power factor self-correcting to > 0.95
• Frequency 60.0 ±2.5 Hz
• Input voltage tolerance +10% to -15%
• Input harmonics < 8% THD

Output

• Solid-state PWM inverter with sine wave output
• Output voltage regulation ±3% of nominal at full load
• Output frequency 60 Hz ±0.2%
• Load power factor capability is 0.6 lagging to unity
• Overload rating: 125% for 10 minutes
• Efficiency: 82% to 86%

Charger

• Low voltage disconnect (LVD)
• 3 amp, 2-stage
• Recharge time: UL 924 compliant

Options

FSU

= Start-up Service

EXT

= Extended Warranty (with FSU only)

How to Specify:

31.0”

78.7 cm

39.0”

99.1 cm

550 VA

1000 VA

1500 VA

Cabinet &

223 lbs.

223 lbs.

262 lbs.

Electronics

(101 kg)

(101 kg)

(119 kg)

Sealed Lead
Calcium Battery

10 Minute

44 lbs.

59 lbs.

88 lbs.

Backup

(19.9 kg)

(26.8 kg)

(39.9 kg)

20 Minute

54 lbs.

88 lbs.

108 lbs.

Backup

(24.5 kg)

(39.9 kg)

(49.0 kg)

90 Minute

121 lbs.

203 lbs.

288 lbs.

Backup

(55 kg)

(92 kg)

(131 kg)

LUPS

Series

VA Rating

Voltage

Output Circuit

Configuration

Breakers

LUPS

= LUPS Uninterruptible

550 = 550 VA

Input Output OCB1 = (550 VA)

Power Supply for

1000 = 1,000 VA

A = 120 120 OCB3 = (1000, 1500 VA)

Emergency Lighting

1500 = 1,500 VA

B = 277

277

Applications

LUPSX

= 10 Minute Backup

LUPSY

= 20 Minute Backup

16.6”

42.2 cm

Operates incandescent, electronic ballast loads and HID lighting loads as well as critical loads requiring conditioned emergency power.