Mounting Methods

Dimensions

Features

• Direct/indirect lamp shield appearance.
• Perforated mesh lamp shield with white acrylic overlay.
• Contoured body and ends.
• Air return models meet UL 1598, Paragraph 9.2.2.5 requirements.
• 68.1% efficient (2 lamp).
• 55.2% efficient (3 lamp).
• Spacing to mounting ratio 1.4 (2 lamp).
• Spacing to mounting ratio 1.3 (3 lamp).
• Only 5" deep.
• Tension bars secure ends to body.
• Same fixture fits both G and T ceiling.
• Fits flush to face of slot grid (T) ceiling.
• Static models have injection molded light stop at basket ends.
• Perforated lamp shield hinges from either side.
• Ballast accessible from room side.
• Can be continuous row mounted.
• Wiring access plate standard.
• Construction to meet NYC Code or Chicago Plenum requirement is

available.

Job Infor mation

Type:

Job Name:

Cat. No.:

Lamp(s):

Volts/Ballast:

11/05

Coffaire

II

Recessed Fluorescent

CFH2GPF2FT or 3FT

Page 1 of 2

Direct/Indirect – 2' x 2' with Perforated Basket

Air Handling/Static, 2 Lamp or 3 Lamp, Twin Tube T5

lamp shield hinges either side

exposed t-grid ceiling

exposed slot t-grid ceiling

Acoustical
material
by others

Exposed T-bar
by others

1-1/2"
max.

Acoustical
material
by others

15/16"

24"

1-7/8"
max.

Exposed T-bar
by others

9/16"

24"

24" (610mm)

5"

(127mm)

2-1/2"

(64mm)

2" x 2-1/2" Access Plate
with (2) 7/8" dia. K.O.

24" (610mm)

Lightolier

a Genlyte company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 a Genlyte company

Section 5/Folio M15-25

built-in earthquake clips

light stop-static models only