Lightolier C2 Series - Manual

Lightolier C2 Series

Lightolier C2 Series – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
Page: / 2
Loading the manual

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • D0308

Job Information

Type:

Job Name:

Cat. No.:

Lamp(s):

Notes:

C2 Series Emergency Lighting

C2

Page 1 of 2

6 or 12 Volt 14 to 50 Watts Thermoplastic Housing

Lightolier is a Philips group brand

Features

1. Illumination:

Allows up to four mounted lamp heads. The standard head

incorporates a high performance parabolic reflector with a wedge base
tungsten lamp. Allows maximum spacing between units along a path of
egress.

2. Housing:

Constructed of 18 gauge steel with a white epoxy powder coat

finish. Designed for easy drop-in installation into suspended ceilings.

3. Electronics:

120/277 VAC dual voltage input with surge-protected, solid-

state circuitry. Charging system is complete with low voltage disconnect, AC
lockout, brownout protection, AC indicator lamp and test switch.

4. Battery:

Maintenance free, sealed lead calcium battery has an estimated

service life of 5 years, and an operating temperature range of 65°F (19°C)
to 85°F (30°C). Maintenance free, sealed nickel cadmium battery has an
estimated service life of 10 years, and an operating temperature range of
20°F (-7°C) to 95°F (35°C).

5. Input Power Requirements:

120 VAC - 0.18 amps, 20 watts;

277 VAC - 0.08 amps, 20 watts

Code Compliance

UL 924 listed.

Options

SD

= Self-Diagnostics

SA

= Self-Diagnostics with Alarm

T1

= 120 VAC Time Delay

T2

= 277 VAC Time Delay

V

= Voltmeter

A

= Ammeter

F1

= 120 VAC Fuse

F2

= 277 VAC Fuse

P1

= 120 VAC Power Switch

P2

= 277 VAC Power Switch

Multiple option configurations may void UL listing. Consult factor y for specifics.

How to Specify:

SERIES

DC VOLTAGE

BAT TERY

# OF

L AMP

HEADS

HEADS

C2

C2 = Recessed
Emergency Lighting
Unit

6V Round Wedge Base

RT6 = 5.4W Tungsten

RT7 = 7.2W Tungsten

RT9 = 9W Tungsten

RH7 = 7W Halogen

RH10 = 10W Halogen

RH12 = 12W Halogen

12V Round Wedge Base

RT9 = 9W Tungsten

RT12 = 12.5W Tungsten

RT18 = 17.9W Tungsten

RH12 = 12W Halogen

4 = Four

3 = Three

2 = Two

1 = One

Blank = No Lamp Heads

1 = 6 volt
2 = 12 volt

6V, Lead Calcium

25L = 25W Unit

50L = 50W Unit

6V, Nickel Cadmium

14N = 14W Unit

25N = 25W Unit

12V, Lead Calcium

50L = 50W Unit

12V, Nickel Cadmium

25N = 25W Unit

50N = 50W Unit

12.0”

(30.5 cm)

17”

(43.2 cm)

5.8”

(14.7 cm)

24.0”

(61.0 cm)

Recessed depth is 4.3”

6.0”

(15.2 cm)

For additional lamp heads, see
RT66 Specification Sheet

The C2 Series provides low profile, recessed emergency lighting for commercial interiors. It is also available as a master unit for remote operation.