Lifebreath TFPC2000 - Manual

Lifebreath TFPC2000

Lifebreath TFPC2000 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4

Table of Contents:

  • Page 2 – Type 1 Installation; TYPE 1 INSTALLATION; TFP; Figure 1; Figure 2; Round port bent to oval
  • Page 3 – TFP Connected to Heat Recovery Ventilator; LOCATION; TYPE 2 INSTALLATION; F L O O R J O I S T S; CAUTION; Figure 3
  • Page 4 – TYPE 3 INSTALLATION; Type 3 Installation
Loading the manual

1 TFP
4 mounting brackets
4 hanging straps
2 oval collar connections
4 8/32” X 3/4” sheet metal screws
8 8/32” X 3/8” sheet metal screws
4 pieces of mounting foam
1 set of installation \ operating instructions
1 warranty card
1 wiring diagram

The TFP is equipped with a standard power supply,
on a 5’ 5” cable. Lighted ON/OFF switch.

Materials Supplied

Electrical

* LEAVE FOR HOMEOWNER

NOTE: Due to ongoing research and product development, specifications,

ratings and dimensions are subject to change without notice.

TFP-06

0204

INSTALLATION MANUAL FOR TFP AIR CLEANER

TFP2000 (Wholehouse Model)

TFPC2000 (Portable Console Model)

The TFP can be installed in several different ways.
Please read all suggested methods before
attempting installation.

ATTENTION

The furnace fan and/or HRV must operate
continuously for Type 1 and Type 2 installations.
If they do not operate continuously, then
interlocking them electrically with the TFP is
acceptable. Consult a certified electrician.

ATTENTION

WHOLEHOUSE AND PORTABLE

CONSOLE MODELS

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Type 1 Installation; TYPE 1 INSTALLATION; TFP; Figure 1; Figure 2; Round port bent to oval

2 TFP Directly Connected to Forced Air Heating System 1. Install 6” oval port collar (provided) on top and bottom of TFP (Fig. 1). Use (4) 8/32” X 3/8”screws (provided). 2. Remove protective backing from pieces offoam and stick them to the 4 corners of the TFPon the side being mounted against the pl...

Page 3 - TFP Connected to Heat Recovery Ventilator; LOCATION; TYPE 2 INSTALLATION; F L O O R J O I S T S; CAUTION; Figure 3

3 TFP Connected to Heat Recovery Ventilator LOCATION The TFP should be located in the main trunk of the fresh air to house line, after the Heat Recovery Ventilator (HRV) and before any branch lines. (Fig. 3) MOUNTING1. Locate mounting bolts (4) on side of TFP cabinet for vertical hanging (Fig. 3) an...

Page 4 - TYPE 3 INSTALLATION; Type 3 Installation

TFP Independent Installation No HRV, Radiant Heating System LOCATION 1. A TFP is usually installed in a basement area where air flow noise will be negligible to the occu-pants. 2. A central location between the clean air supply grille and return grille is recommended. MOUNTING Refer to “Mounting” un...

Other Lifebreath Models

All Lifebreath Other