Lifebreath 99-MD-KIT - Manual

Lifebreath 99-MD-KIT

Lifebreath 99-MD-KIT – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
Page: / 24

Table of Contents:

  • Page 2 – Engineering Data - HRV; inches; inches
  • Page 3 – Motorized Damper Assembly
  • Page 4 – Installation; Clearances and Requirements; WARNING; CAUTION
  • Page 5 – Not into a garage, workshop or other unheated space; • Should be located upstream (if there are prevailing; * Local code may require greater distances.; Weather Hood Clearances; Weatherhood Installation
  • Page 6 – the; DRAIN HOSE PLUMBING; HARD PIPE PLUMBING; Air Duct Design and Installation
  • Page 7 – Remote Control Connections
  • Page 8 – Forced; REMOTE DEHUMIDISTAT; • anywhere humidity is a concern; Dehumidistat Operation; PROBLEMS
  • Page 9 – Balancing Procedure; CROSS SECTION AREA; Air Flow Balancing
  • Page 10 – Placement of Pitot Tube HRV; Pitot Tube and Gauge; Pitot Tube Air Flow; with magnehelic gauge,; NOTE: Apply use of balancing dampers as required.
  • Page 11 – Maintenance
  • Page 12 – Notes
  • Page 15 – T ube de Pitot et débitmètre; Nécessaire d’équilibrage; avec tube de Pitot incluant; Ce schéma n’est offert qu’à des fins d’illustration. Les
  • Page 16 – A TTENTION; Équilibrag
  • Page 17 – DÉSHUMIDISTAT À DISTANCE; *qui exige deux fils; s’emploie partout où il y a beaucoup d’humidité; Pièce N; Fonctionnement du déshumidistat; Basse tension - courant alternatif de 24 volts
  • Page 18 – Connexions pour télécommandes; A VER
  • Page 19 – comme protection contre les fuites d’eau de condensation.
  • Page 21 – Raccordement d’appareils au VRC; • sécheuse à linge; Dégag
  • Page 23 – Dimensionsdu
Loading the manual

Installation Tools

tin snips

large zip ties

assorted screw drivers

fabric flexible duct

electric drill

- class

II

rated

hammer

mastic tape

wire strippers

alum. foil duct tape

knife

zip ties

caulking gun

1/2” I.D. drain hose

smoke pencil

Balancing Tools

Pitot Tube Balancing Kit
[Case, 8 ft. vinyl tubing, Pitot tube,
magnehelic gauge (0 - 0.25”), and

mounting plate]

Pitot Tube with instructions

and Digital Manometer (with resolution of
0 - 0.25” - must read to 1/100ths of an inch)

Heat Recovery Ventilators (HRV) are designed to provide
fresh air while exhausting an equal amount of stale air.
The HRV is equipped with an aluminum core. The device
uses the stale air that is being exhausted to condition the
fresh air as it is being brought in.

These instructions are intended as a general guide and do
not supersede local codes in any way. Consult authorities
who have jurisdiction before installation.

Required Tools ................................................................1

Application.......................................................................1

General ...........................................................................1

Table of Contents ............................................................1

Engineering Data ............................................................2

Motorized Damper Assembly ..........................................3

Clearances & Requirements ...........................................4

Installation ....................................................................4-6

Electrical .........................................................................7

Dehumidistat Operation ..................................................8

Air Flow Balancing .....................................................9-10

Maintenance .................................................................11

I N S T A L L A T I O N I N S T R U C T I O N F O R F R E S H A I R E X C H A N G E R

Application

General

Table of Contents

Required Tools

* LEAVE FOR HOMEOWNER

NOTE: Due to ongoing research and product development, specifications,

ratings and dimensions are subject to change without notice.

TI-FAE-001

1207

MODELS 94-EXCHANGER, 94-EXCHANGER-MD, 99-MD-KIT

See page 3 for 99-MD-KIT installation instructions

ATTENTION

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Engineering Data - HRV; inches; inches

2 MODEL 94-EXCHANGER-MD - Includes 24 volt motorized damper 21.25" (540 mm) STALE AIR TO OUTSIDE FRESH AIR FROM OUTSIDE STALE AIR FROM INSIDE FRESH AIR TO INSIDE 15" (380 mm) 18.75" (475 mm) * A l l D u c t C o n n e c t i o n s 6 " ( 1 5 0 m m ) F I LT E R B A L A N C I N G C O L L ...

Page 3 - Motorized Damper Assembly

3 Motorized Damper Assembly Mount the damper motor by aligning the four (4) holes inthe mounting plate to the four holes on the unit’s top plate.This will automatically align the damper motor couplingwith the damper shaft. Align the damper in the fully closed position. Using a 1/8”Allen key to tight...

Page 4 - Installation; Clearances and Requirements; WARNING; CAUTION

4 Location Selection The HRV must be located in a heated space where it willbe possible to conveniently service the unit. Typically theHRV would be located in the mechanical room or an areaclose to the outside wall where the weather hoods will bemounted. If a basement area is not convenient or does ...

Other Lifebreath Models