Page 2 - Engineering Data - HRV; inches; inches

2 MODEL 94-EXCHANGER-MD - Includes 24 volt motorized damper 21.25" (540 mm) STALE AIR TO OUTSIDE FRESH AIR FROM OUTSIDE STALE AIR FROM INSIDE FRESH AIR TO INSIDE 15" (380 mm) 18.75" (475 mm) * A l l D u c t C o n n e c t i o n s 6 " ( 1 5 0 m m ) F I LT E R B A L A N C I N G C O L L ...

Page 3 - Motorized Damper Assembly

3 Motorized Damper Assembly Mount the damper motor by aligning the four (4) holes inthe mounting plate to the four holes on the unit’s top plate.This will automatically align the damper motor couplingwith the damper shaft. Align the damper in the fully closed position. Using a 1/8”Allen key to tight...

Page 4 - Installation; Clearances and Requirements; WARNING; CAUTION

4 Location Selection The HRV must be located in a heated space where it willbe possible to conveniently service the unit. Typically theHRV would be located in the mechanical room or an areaclose to the outside wall where the weather hoods will bemounted. If a basement area is not convenient or does ...