Liebert 130 kVA - Manual

Liebert 130 kVA

Liebert 130 kVA – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
80 Page 80
81 Page 81
82 Page 82
83 Page 83
84 Page 84
85 Page 85
86 Page 86
87 Page 87
88 Page 88
89 Page 89
90 Page 90
91 Page 91
92 Page 92
93 Page 93
94 Page 94
95 Page 95
96 Page 96
97 Page 97
98 Page 98
99 Page 99
100 Page 100
101 Page 101
102 Page 102
Page: / 102

Table of Contents:

  • Page 2 – User Manual
  • Page 3 – To deliver value
  • Page 5 – and one plus one Systems.; EMERSON NETWORK POWER (INDIA) PRIVATE LIMITED; @ Copyright 1999 by Emerson Network Power
  • Page 7 – REGISTERED HEAD OFFICE; Emerson Network Power (India) Private Limited
  • Page 11 – WARNING
  • Page 13 – GENERAL
  • Page 15 – General Introduction; I N D E X
  • Page 17 – Operating Instructions
  • Page 19 – Display Panel Interpretation
  • Page 21 – General Description; Introduction; Increased power quality:; variations on the mains power lines.; Increased noise rejection:; the UPS output, therefore the critical load sees only clean power.; Power blackout protection:; Design Concept; Hipulse Module Design; RECTIF IER
  • Page 22 – capacity and the applied percentage load.; side or in the maintenance bypass mode; Fig 1-2 : UPS Power switches configuration
  • Page 24 – sustained by the number of active modules in the system.; Maintenance Bypass; ECOMODE; or later (the S/W release of the cards may be
  • Page 25 – In ECOMODE the load is not protected against mains distortion.
  • Page 27 – Installation Procedure; Remove rings, watches and all metal objects.; NOTE
  • Page 29 – Clearances; passage of personnel with the doors fully opened.; Fixing magnetic components; output transformer in place.; Cable entry
  • Page 30 – Preliminary Checks; damage to the shipper immediately.; Installation Drawings
  • Page 31 – Fig 2-1: Overall General Arrangement for 130kVA Single Phase UPS
  • Page 33 – metalwork of the cabinets to which they are connected.; Power Cabling; System Configuration
  • Page 34 – Phase Input Mains with full; UPS; seconds or as guided by local electrical rules.; Cable Connections; the earth busbar and bonded to each cabinet in the system.
  • Page 35 – Protective devices; Rectifier and bypass inputs:; Split Bypass; They are identified by the symbols respectively.
  • Page 36 – the System Bypass Mains.; Cabling procedure; cables as described in the following procedure.; codes practice; ENSURE CORRECT PHASE ROTATION
  • Page 37 – Auxiliary Connections:
  • Page 38 – Fig 3-1 : Cable connections for 130 kVA 1Ph UPS; SUPPLY
  • Page 39 – Control cables; Battery Control; CAUTION; Fig 3-2 : Auxiliary Terminal Block detail; LINKS
  • Page 41 – To Battery
  • Page 43 – Operator Control and Display Panel; ‘Operator Panel’ and ‘LCD display’,
  • Page 44 – and show the current UPS operation status:; Inverter control switch; Fig 4-2: Single module operator control panel
  • Page 45 – ESC Pressing the ESCAPE cancels the most recent actions; Operator Panel and LCD Display; selected metered parameters.
  • Page 46 – C) at critical points; Bargraph Selection
  • Page 47 – windows are described below.
  • Page 48 – Fig 4 - 4: Map of screen display available to operator; PRESS DOWN KEY
  • Page 49 – The message shown below, will be seen on the; Info Window
  • Page 50 – possible to change them without password.; Option Selection Mode; Press ESC to return the previous window to the screen.
  • Page 51 – CHAPTER 5; Normal operation
  • Page 52 – Procedure for UPS Start-up: without interrupting power; This procedure will describe; Initializing Window:
  • Page 53 – The Display window will show the present status; In ECOMODE the Load on Mains led (6) stays on
  • Page 54 – Procedure for UPS Startup without power initially; isolators Q1 to Q4, and Operator control Panel respectively.; The following action will apply power to load the; press the ENTER key:
  • Page 55 – change to the default window.; The UPS is operating normally with its
  • Page 56 – Procedure for Switching the UPS into a Maintenance; IF YOUR ARE NOT SURE OF WHAT YOU ARE DOING
  • Page 57 – supplied by the manual bypass.; Your load is now powered from the maintenance bypass
  • Page 58 – Procedure for completely powering down the UPS; Note
  • Page 59 – The UPS is now completely powered down.; IMPORTANT; Procedure for carrying out a RESET after a recognized; Press the ENTER key.; In ECOMODE the message 'LOAD ON BYPASS'
  • Page 60 – switch to operate normally.; Adding a single module to an existing system
  • Page 61 – UPS Display Control Panel:; IF YOU ARE NOT SURE WHAT YOU ARE DOING,
  • Page 64 – Setting the Battery Test; instructions given below initiates an immediate battery test.; turn off the indicating the remaining autonomy time.; revert to normal operation.; ‘BATTERY: TEST FAILED’ alarm will be displayed on the default screen.
  • Page 65 – now be stored in the selected language.; Changing the current Date and Time
  • Page 67 – CHAPTER 6; Battery Installation; Autonomy time’ (the time that; Safety
  • Page 68 – Only qualified personnel should install or service batteries.; of which have been used in the past.
  • Page 69 – Installation design considerations; Temperature considerations; Parameter; Float voltage; Table 6-1 – Battery population
  • Page 70 – Battery protection
  • Page 72 – Layout of the cells:; All connections must be as short as possible.; Battery Protection Circuit Breaker:; pulse is described in the following paragraph.; Battery circuit breaker:; When installing the battery
  • Page 73 – Figure 6-3: Battery Control and Power Connections
  • Page 74 – Battery temperature Board; This prevents the battery being over charged at high ambient.
  • Page 75 – The LED item number refers to details shown in the figure 7.1 below.; NORMAL; Fig 7-1: Single module operator control panel
  • Page 77 – Display Panel Messages; The message displayed on Hipulse can be categorized into types:-; Interpretation; EMERGENCY STOP
  • Page 83 – General; the main bypass supply.
  • Page 84 – D I S T R I B U T I O N
  • Page 85 – Installation procedure; Protective Devices
  • Page 87 – Operating Instruction; System Start-up and shutdown procedures (Separate Batteries)
  • Page 90 – NORMAL OPERATION appearing on the display operator panel.; CODE; The number of active inverters is below the preset capacity value.
  • Page 91 – Specification; Conformity and Standard; damage or degradation in electrical operating characteristics:; Environmental Characteristics; Rated Power; UPS Mechanical Characteristics; pulse
  • Page 92 – UPS Electrical Characteristics; R E C T I F I E R I N P U T M A I N S; Rated power
  • Page 93 – UPS Electrical Characteristics (DC Intermediate Circuit); D. C. I N T E R M E D I A T E C I R C U I T
  • Page 94 – UPS Electrical Characteristics (Inverter Output); I N V E R T E R O U T P U T
  • Page 95 – B Y P A S S I N P U T M A I N S
  • Page 99 – Table A
  • Page 100 – Figure 10.1: Remote Alarm Monitor connection details; Liebert
  • Page 101 – INPUT TRANSFORMER CUBICLE; Utility socket is provide for single phase supply
  • Page 102 – BYPASS ISOLATION CUBICLE; Bypass Supply to the UPS Panel.
Loading the manual

User Manual

Hipulse - Single Phase ‘1+N’ UPS System

130 kVA - 110V


User Manual – Hipulse

Installation & Maintenance of Hipulse 130kVA Single phase 110V, Single & 1 + N System

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - User Manual

User Manual Hipulse - Single Phase ‘1+N’ UPS System 130 kVA - 110V

Page 3 - To deliver value

User Manual Hipulse - Single Phase ‘1+N’ UPS System 130 kVA - 110V Dear Customer, Please accept our thanks for giving us the privilege to serve you by choosing a Liebert make ‘UPS’. If this is your first Liebert UPS, we hope it is the beginning of a long relationship which delivers value to your org...

Page 5 - and one plus one Systems.; EMERSON NETWORK POWER (INDIA) PRIVATE LIMITED; @ Copyright 1999 by Emerson Network Power

User Manual Hipulse - Single Phase ‘1+N’ UPS System 130 kVA - 110V Rev. No. Revision details Date IMPORTANT This manual contains information concerning the installation, operation and maintenance of the Hipulse Uninterruptible Power System (UPS) for the single module and one plus one Systems. All re...

Other Liebert Models

All Liebert Other