LG ARWM121BAS5 - User Manual

LG ARWM121BAS5

LG ARWM121BAS5 Air Conditioner – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
Page: / 57

Table of Contents:

  • Page 2 – TIPS FOR SAVING ENERGY; WARNING; Installation; ENGLISH; For your records
  • Page 3 – CAUTION; TABLE OF CONTENTS
  • Page 4 – SELECT THE BEST LOCATION; OUTDOOR UNITS INFORMATION
  • Page 5 – NOTE
  • Page 6 – INSTALLATION SPACE
  • Page 7 – The location of the Anchor bolts; INSTALLATION
  • Page 8 – Foundation for Installation; Preparation of Piping
  • Page 9 – Flare shape and flare nut tightening torque; Opening shutoff valve; Tightening torque; Plumbing materials and storage methods; Refrigerant piping on three principles
  • Page 10 – Nitrogen substitution method; Precautions on Pipe connection / valve operation; For Heat Recovery System Installation
  • Page 11 – Connection of Outdoor units; Installation procedure for HR unit
  • Page 12 – HR Unit; HR Unit; Type of HR Unit
  • Page 13 – Installation of Zoning Control
  • Page 14 – Cautions in pipe connection/valve operation; For Heat Pump System Installation
  • Page 16 – Water pipe connection; Head loss of strainer on water pipe; Water pipe system diagram; DEVICE PROTECTION UNIT
  • Page 17 – Installation of flow switch; Flow switch work; Outdoor Units
  • Page 19 – Y branch, Header and HR unit connection pattern; Pattern 1; Pattern 2; Pattern 3; Pattern 7; • * : Serial connection of HR units : Capacity sum of indoor units
  • Page 20 – Pattern 8; • * : Maximum indoor units per a branch are 8 indoor units; Y branch method; Refrigerant piping system
  • Page 21 – Header method
  • Page 22 – Outdoor unit Connection
  • Page 23 – Oil trap application method between outdoor units
  • Page 24 – Refrigerant charging; The amount of Refrigerant
  • Page 25 – Branch pipe Fitting
  • Page 26 – Y branch pipe
  • Page 28 – Header; Slave; Distribution Method
  • Page 29 – Vacuum Mode
  • Page 30 – Leak Test and Vacuum drying
  • Page 31 – Thermal insulation of refrigerant piping; Penetrations
  • Page 32 – ELECTRICAL WIRING
  • Page 33 – Control Box and Wiring Location; External Board
  • Page 34 – Field Wiring
  • Page 38 – Checking the setting of outdoor units; DIP switch
  • Page 39 – Switch for setup of HR Unit
  • Page 42 – Automatic Addressing
  • Page 43 – The Procedure of Automatic Addressing
  • Page 44 – * It is possible to be generated mode; Flow chart of auto pipe detection Process
  • Page 46 – Identification of Manual Valve ID (Address); DIP switch setting
  • Page 47 – Group Number setting
  • Page 48 – Left side
  • Page 49 – Central Control Connection at Indoor Unit side (Fn 19)
  • Page 50 – TEST RUN; Precaution before test run
  • Page 51 – Water supply system test run; How to Cope with Abnormal Test Run
  • Page 52 – Daily check/management; Maintenance of plate type heat exchanger
  • Page 53 – Self-Diagnosis Function
  • Page 55 – Checking procedure of limiting concentration; Introduction; CAUTION FOR REFRIGERANT LEAK
  • Page 56 – Individual Control (Use 220 V Output Port); DDC; Main PCB; side
Loading the manual

Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring standards by
authorized personnel only.
Please retain this installation manual for future reference after reading it thoroughly.

For Heat Pump / Heat Recovery system

Original instruction

INSTALLATION MANUAL

AIR

CONDITIONER

MFL71705501

Rev.05_021022

www.lghvac.com

www.lg.com

Copyright © 2020 - 2022 LG Electronics Inc. All Rights Reserved.

ENGLISH

ESP

AÑOL

FRANÇAIS

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TIPS FOR SAVING ENERGY; WARNING; Installation; ENGLISH; For your records

2 TIPS FOR SAVING ENERGY Here are some tips that will help you minimize the power consumption when you use the air conditioner. You can use your air conditioner more efficiently by referring to the instructions below: IMPORTANT SAFETYINSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING THEAPPLIANCE. Alwa...

Page 3 - CAUTION; TABLE OF CONTENTS

3 CAUTION Installation • Always check for gas (refrigerant) leakage after installation or repair of product. - Low refrigerant levels may cause failure of product. • Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods.- It may cause a problem fo...

Page 4 - SELECT THE BEST LOCATION; OUTDOOR UNITS INFORMATION

4 ENGLISH The foundation must be level even Outdoor unit foundation work Avoid short circuits and ensure sufficient space is allowed for service Installation of outdoor unit Refer to automatic addressing flowchart Automatic addressing of indoor unit In the final check for 24 hours at 3.8 MPa (38.7 k...

Other LG Air Conditioners Models