Lennox X-FIRES-WS-NG - Manual

Lennox X-FIRES-WS-NG

Lennox X-FIRES-WS-NG – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
Page: / 20

Table of Contents:

  • Page 3 – .0 GENERAL INFORMATION; Fireplace; APPLIANCE SPECIFICATIONS; Table 1
  • Page 4 – UNPACKING THE APPLIANCE
  • Page 5 – COMBUSTION AND VENTILATION AIR; Unusually tight construction is defined as construction where:; WARNING; Air for Combustion
  • Page 6 – CLEARANCES TO NON-COMBUSTIBLES; CAUTION; The back of the appliance may be installed directly
  • Page 7 – PREPARING THE APPLIANCE; Figure 2; Wall Mounting Plate; GAS SUPPLY ROUTES; IMPORTANT NOTE: All gas piping must be done by
  • Page 8 – Figure 3 - Wall Fixing Template; FPO; MOUNTING THE APPLIANCE; The wall where the appliance is to be installed must; Installation onto anything other; Figure 3; Lennox
  • Page 9 – When selecting the height, ensure that the clearance to the; Figure 4; FITTING THE SURROUND ASSEMBLY; Due to the weight of the frame assembly, it is recommended to seek; Figure 5; Heat Shield
  • Page 10 – CHECKING THE BURNER; Figure 6; Hold heater regulator with a wrench to prevent; Connecting directly to a unregulated propane; CHECKING THE GAS CONNECTIONS; Never use an open flame to check for leaks.; Checking Manifold Pressure at Provided Test Point (see; See
  • Page 11 – Figure 7a; Pressure Setting; Figure 8 - Proper Spark Gap; BRIEFING THE CUSTOMER; Do not add logs or ornaments such as pine cones,; obstruction this area in any way.; Adjustment to the
  • Page 13 – Do not block the catalysts or the appliance outlet grill.; Figure 9 - Catalysts and Outlet Grill; IMPORTANT: The temperature of the gases emitted by the catalytic; .0 TESTING FOR FIREBOX LEAKAGE; Do not operate the appliance with the catalyst units; DO NOT BLOCK
  • Page 14 – TO TURN OFF GAS TO APPLIANCE; Pilot assembly. This is located; ‘OFF’ position
  • Page 15 – be the problem and removal of the draft should resolve this.
  • Page 16 – Replacement Parts; See ordering instructions on Page 20
  • Page 17 – POSITIONING OF FIELD REMOVABLE PARTS; Glass Door Removal: Remove; Failure to position the parts in; Visual check for cor-; off burner
  • Page 18 – Limestone Surround; Product Reference Information; Surround Specifications; character with no two pieces being quite the same.
  • Page 19 – REGULATOR GAS ENTRY POINT
  • Page 20 – WARRANTY; LENNOX HEARTH PRODUCTS; PRODUCT REFERENCE INFORMATION; Natural Gas
Loading the manual

Report No. 317-F-11-5

INSTALLATION AND OPERATION MANUAL

WARNINGS

Hot! Do not touch! This appliance will be hot during operation and will retain heat for a while after

shutting off the appliance. Severe burns may result.

Carefully supervise children in the same room as appliance.

Due to high temperatures, the appliance should be located out of traffic and away from furniture or

draperies.

• Do not place clothing or other materials on or near this appliance.

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to

this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

Do not build a wood fire. Do not burn wood or other material in these appliances.

This is an unvented gas log appliance. It uses air (oxygen) from the room in which it is installed. Provisions for adequate

combustion and ventilation air must be provided. Refer to Combustion and Ventilation Air Section in this manual.

• This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home, where

not prohibited by local codes.

• The appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible

for use with other gases.

• Lennox™ vent-free appliances are designed for use as a supplemental heater. They are not intended for continuous

use as a primary heat source.

P/N 506023-05 REV. B, 05/2009

I

n the Commonwealth of Massachusetts:

• Installation must be performed by a licensed plumber or gas fitter

• See Table of Contents for location of additional Commonwealth of

Massachusetts requirements

US

Portland

Installer: Leave This Manual With The Appliance.

Consumer: Retain This Manual For Future Reference.

X-Fires™ WS

TM

Wide Screen Models

X-FIRES-WS-NG and X-FIRES-WS-LP

Catalytic Vent-Free

Wall-Mounted Gas Fireplaces

- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appli-

ance.

- WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in your building.

• Immediately call your gas supplier fr

o

m a neighbor’s phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

- Installation and service must be performed by a qualified installer, service agency or the gas supplier.

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing

property damage, personal injury or death.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - .0 GENERAL INFORMATION; Fireplace; APPLIANCE SPECIFICATIONS; Table 1

3 .0 GENERAL INFORMATION This appliance is a high efficiency, unvented, flame effect gas heater. It provides radiant and convected warmth both efficiently and safely utilizing the latest type catalytic convertor burner technology. The appliance does not require a flue system of any type as the catal...

Page 4 - UNPACKING THE APPLIANCE

4 6.0 BURN-IN PERIOD On initial light up of a new appliance, the ‘newness’ will burn off within the first few hours of operation. During this period some smoke may be emitted from outlet grill, this should be no cause for concern. Accord- ingly, the room should be well ventilated with all windows an...

Page 5 - COMBUSTION AND VENTILATION AIR; Unusually tight construction is defined as construction where:; WARNING; Air for Combustion

5 8.0 COMBUSTION AND VENTILATION AIR This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. The heater may be located in unusually tight construction provided the space is unconfined, or if co...