Lennox MPD35PF-NE-B - Manual

Lennox MPD35PF-NE-B

Lennox MPD35PF-NE-B – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
Page: / 44

Table of Contents:

  • Page 2 – TABLE OF CONTENTS; Please read and understand these; WARNING; GENERAL INFORMATION
  • Page 3 – Table 1
  • Page 5 – LOCATION; peu de circulation et loin du mobilier et des tentures (Figure 3).; COLD CLIMATE INSULATION; Figure 3; When the unit is installed with one side flush with a
  • Page 6 – VENT TERMINATION CLEARANCES; Termination Heights For Vents; Figure 6; Horizontal Vent Termination Clearances; Side Elevation View; Figure 4 - Multiple Terminations; Minimum
  • Page 7 – EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS
  • Page 8 – Hearth Extension; Combustible wall finish materials and/or
  • Page 9 – Table 5; DETAILED INSTALLATION STEPS; Remove the shipping carton. Remove the shipping pad, exposing; One end of the unit may be; Figure 9
  • Page 10 – Figure 12 - Nailing Flanges; Figures; DO NOT; TYPICAL INSTALLATION SEQUENCE; (Page 13) Route gas supply line to; Handle logs carefully to
  • Page 11 – FIREPLACE SPECIFICATIONS - MPD35ST; Use a plumb line
  • Page 12 – FIREPLACE SPECIFICATIONS - MPD35PF
  • Page 13 – Table 6; IMPORTANT: If propane is used, be aware that; Step 3. PREPARING THE APPLIANCE; Figure 15 - Route Gas Line; Step 2. ROUTING GAS LINE
  • Page 14 – Approved Vent; on; the joints in the vent pipe.; restrictor in the top vent of the fireplace outlet.
  • Page 15 – Note: Convert inches into metric equivalent; Effective Vent Length; Model; Table 7; Pages 18, 19 and 20 and their associated; Secure VentTM; Figure 5; Tables on this page
  • Page 16 – An elbow may also be attached to the
  • Page 17 – Swivel Joint
  • Page 18 – VERTICAL VENT FIGURES/TABLES; Secure Vent; rate sections of concentric flexible; Maximum; Ratio V to H ratio is 1:2
  • Page 19 – Ceiling; ) horizontal vent run is needed, then 4 feet minimum; Top Vent - THREE ELBOWS
  • Page 21 – tion Guard; in the same manner as any SV4.5; Venting Connection and Exterior Wall Recessing of the
  • Page 22 – Table 8; HORIZONTAL VENT FIGURES/TABLES; in a straight (no dips) and recommended to be in a slightly elevated; When using; If 20 feet of (H) horizontal vent run is needed, then 4 feet; Under no circumstances, may separate sections of
  • Page 23 – ) horizontal run, up to a maximum horizontal
  • Page 25 – Figure; SECuRE FlEx; Secure Flex
  • Page 26 – Verify proper operation after servicing.; CAUTION
  • Page 27 – Note: Supply wires may be alternatively con-; WIRING - OPTIONAL FORCED AIR; Valve Access Side; Step 7. CONNECTING GAS LINE; Secure all joints tightly using appropriate; Remove the carton support from; TEST ALL CONNECTIONS FOR GAS LEAKS
  • Page 28 – TION; Schematic Representation Only
  • Page 29 – Millivolt Appliance Checkout; ING EMBERS AND LOGS; Electronic Appliance Checkout
  • Page 30 – Glowing Embers; Bag of Glowing; Top View of Logs; LOG SET; LOG SET - IDENTIFICATION
  • Page 31 – Embers
  • Page 32 – Position The Round End Of Log (E) Against The Notch Of
  • Page 34 – Burner Flame Appearance
  • Page 35 – This Area Must Remain; HOOD INSTALLATION; Refer to Figure 65. All of these appliances; FINISHING REQUIREMENTS; Complete finished interior wall. To install the; See Page 5 for
  • Page 36 – WARNINGS; ). To properly complete the installation of; APPOSITION DES MISES EN GARDE RELATIVES; LENNOX HEARTH PRODUCTS; COLOCACIóN DE ADVERTENCIAS DE SEGURIDAD; ) y en el transmisor; LENNOX HEARTH PRODUCTS; Figure A
  • Page 37 – rigid; INSTALLATION ACCESSORIES; Listed Secure VentTM Components
  • Page 38 – INSTALLATION ACCESSORIES CONTINUED; All compressed flex vents can be expanded up to two times.
  • Page 39 – this installation assumes responsibility for this conversion.; AVERTISSEMENT; assume les responsabilités liées à la conversion.; Table 9
  • Page 40 – Gas Valve; All Models; Note: If the igniter is damaged, a replacement kit; Electronic Appliances; Figure 69 and the instructions provided with
  • Page 41 – Pilot Assembly; Elevation; * Standard size installed at factory
Loading the manual

MPD35ST-NM-B

MPD35ST-NE-B

MPD35ST-PM-B

MPD35PF-NE-B

MPD35PF-NM-B

MPD35PF-PM-B

OTL Report No. 116-F-28-5

US

Portland

MODELS

This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile

home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating

plate. This appliance is not convertible for use with other gases unless a certified kit is used.

INSTALLATION INSTRUC

TIONS

MILLIVOLT:

ELECTRONIC:

P/N 850024M Rev. J 01/2011

This manual is one of a set of two supporting this product.

Refer to P/N 875025M for Care and Operation Instructions.
Ce manuel est disponible en francais, simplement

en faire la demande. Numéro de la pièce 850024CF.

AVERTISSEMENT : Assurez-vous de bien suivre les

instructions données dans cette notice pour réduire au

minimum le risque d’incindie ou d’explosion ou pour

éviter tout dommage matériel, toute blessure ou la mort.

- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs

ou liquides inflammables dans le voisinage de cet appareil

ou de tout autre appareil.

- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :

• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir des

téléphones se trouvant dans le bâtiment où vous trouvez.

• Appelez immédiatement votre fournisseur de gaz depuis

un voisin. Suivez les instructions du fournisseur.

• Si vous ne pouvez rejoindre le fournisseur de gaz,

appelez le service des incindies.

- L’installation et l’entretien doivent être assurés par un

installateur ou un service d’entretien qualifié ou par le

fournisseur de gaz.

WARNING: If the information in these instructions

is not followed exactly, a fire or explosion may

result, causing property damage, personal injury,

or death.

-

vapors and liquids in the vicinity of this or any other

appliance.

- WHAT TO DO IF YOU SMELL GAS:

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any

phone in your building.

• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s

instructions.

department.

- Installation and service must be performed by a

WARNING / AVERTISSEMENT / AVISO

• HOT GLASS WILL CAUSE

BURNS.

• DO NOT TOUCH GLASS

UNTIL COOLED.

• NEVER ALLOW CHILDREN

TO TOUCH GLASS.

• UNE SURFACE VITRÉE CHAUDE

PEUT CAUSER DES BRÛLURES.

• LAISSER REFROIDIR LA SURFACE

VITRÉE AVANT D'Y TOUCHER.

• NE PERMETTEZ JAMAIS À UN ENFANT

DE TOUCHER LA SURFACE VITRÉE.

• EL VIDRIO CALIENTE

CAUSARÁ QUEMADURAS.

• USTED DEBE NUNCA

TOCAR EL VIDRIO CALIENTE.

• LOS NIÑOS DEBEN NUNCA

TOCAR EL VIDRIO.

INSTALLER:

Leave this manual with the appliance.

CONSUMER:

Retain this manual for future reference.

INSTALLATEUR :

Laissez cette notice avec l'appareil.

CONSOMMATEUR :

Conservez cette notice pour

consultation ultérieure.

MPD35 Direct-Vent

Gas Fireplaces

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TABLE OF CONTENTS; Please read and understand these; WARNING; GENERAL INFORMATION

2 TABLE OF CONTENTS Packaging .........................................Page 2Introduction ......................................Page 2General Information ..........................Page 2Requirements for the Commonwealth of Massachusetts .Page 4New York City Approval .....................Page 4Cold C...

Page 3 - Table 1

3 WARNING Improper installation, adjust- ment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier. WARNING Failure to comply with these installation i...

Page 5 - LOCATION; peu de circulation et loin du mobilier et des tentures (Figure 3).; COLD CLIMATE INSULATION; Figure 3; When the unit is installed with one side flush with a

5 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. LOCATION In selecting the location, the aesthetic and functional use of the appliance are primary concerns. However, vent system routing to the exterior and access to the fuel supply are also important. Due to high temperatures, the appliance sh...

Other Lennox Models

All Lennox Other