Lennox MLDVTCD-35NE - Manual

Lennox MLDVTCD-35NE

Lennox MLDVTCD-35NE – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
Page: / 38

Table of Contents:

  • Page 2 – TABLE OF CONTENTS; Please read and understand these; WARNING; GENERAL INFORMATION; LENNOX HEARTH PRODUCTS • MERIT
  • Page 3 – Table 1; 0 - latest edition, or the Canadian Electrical
  • Page 4 – Figure 1; SIT Millivolt Gas Valve; Table 4; Tables 2 and 3; less; Table; REQUIREMENTS FOR THE COMMON-
  • Page 5 – Figure 3; Typical Locations; HORIZONTAL VENT; When the unit is installed with one; COLD CLIMATE INSULATION; LOCATION; Do not insulate the space between the ap-
  • Page 6 – Figure 4B; VENT TERMINATION CLEARANCES; These instructions should be used as a; Vertical Vent Termination Clearances; Figure 4A; Figure 5; Figure 5; Horizontal Vent Termination Clearances; Side Elevation View; Termination Heights For Vents; Figure 4A - Multiple Terminations
  • Page 7 – ExTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS; Figure 6
  • Page 8 – MINIMUM CLEARANCES TO COMBUSTIBLES; When the; Table 5; on the underside of the mantel.
  • Page 9 – DETAILED INSTALLATION STEPS; Glass Panels on; Figures; on; Table 5 on Page 8; DO NOT; TYPICAL INSTALLATION SEQUENCE; Figure 47 on Page; Attach Safety in Operation
  • Page 10 – FIREPLACE AND FRAMING SPECIFICATIONS; Vertical Venting Through the Ceiling:; Frame ceiling opening; Framing; Front View
  • Page 11 – FIREPLACE FRAMING SPECIFICATIONS; Table 6; Corner Framing with Horizontal Termination; mm; Step 2. ROUTING GAS LINE; Proper Sizing of Gas Line
  • Page 12 – Figure; Approved Vent Components
  • Page 13 – Note: Convert inches into metric equivalent; Model; Table 7
  • Page 14 – refer to Figure 17)
  • Page 15 – Swivel Joint
  • Page 16 – rate sections of concentric flexible; VERTICAL VENT FIGURES/TABLES; vent will be required.
  • Page 17 – Ceiling; Top Vent - THREE ELBOWS
  • Page 19 – Termination Guard; INSTALLING HORIZONTAL TERMINATION; Venting Connection and Exterior Wall Recessing; See; Table 8
  • Page 20 – Under no circumstances, may separate sections of; HORIZONTAL VENT FIGURES/TABLES; Typical termination shown.; Termination Kit Only; zontal vent run is needed, then
  • Page 22 – See Table 8 on Page 20 as
  • Page 23 – SECuRE FLEXTM
  • Page 24 – CAUTION; Verify proper operation after servicing.
  • Page 25 – No batteries to be installed in the battery; BLOWER CONTROL CIRCUIT WIRING; WIRING - OPTIONAL FORCED AIR; Blower Access
  • Page 26 – external to the appliance between the appliance; Step 6. CONNECTING GAS LINE; Gas
  • Page 27 – Never use an open flame to check; Step 7. VERIFYING APPLIANCE; Page; Millivolt Appliance Checkout; Never use an open flame to
  • Page 28 – Step 8. INSTALLING CONTEMPORARY; Turn off all electricity to the appliance; Remove the front glass enclosure panel
  • Page 29 – MLDVTCD-35 REFRACTORY PANELS AND CONTEMPORARY MEDIA PLACEMENT
  • Page 30 – ) by sliding and pulling the
  • Page 31 – Burner Air Shutter Adjustment Procedure; Main Burner Factory Air Shutter; Figure 45 - Burner Air Shutter Adjustment
  • Page 32 – FINISHING REQUIREMENTS - Contemporary Facade; (use the framing dimensions as-is as shown in; HOOD INSTALLATION; See Page 5 for Cold Climate Insulation; - Combustible Wall Framing; Figure 48 - Contemporary Facade Dimensions; Floor
  • Page 33 – COLOCACIóN DE ADVERTENCIAS DE; ) o en el termostato; LENNOx HEARTH PRODUCTS; WARNINGS; ) and if used on the; LENNOx HEARTH PRODUCTS; Figure A
  • Page 34 – INSTALLATION ACCESSORIES; ir
  • Page 35 – INSTALLATION ACCESSORIES CONTINUED; lf
  • Page 36 – Millivolt; this installation assumes responsibility for this conversion.; AVERTISSEMENT; assume les responsabilités liées à la conversion.; Burner Assembly
  • Page 37 – Millivolt Appliances; Pressure; VERIFY THE PROPER ORIFICE SIZE; Table 9; - Dexen Electronic Gas Valve
Loading the manual

MODELS

This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile

home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating

plate. This appliance is not convertible for use with other gases unless a certified kit is used.

INSTALLATION INSTRUC

TIONS

MLDVTCD Direct-Vent

Contemporary Design

Gas Fireplaces

MLDVTCD-35NM

MILLIVOLT:

MLDVTCD-35NE

ELECTRONIC:

P/N 506015-03 Rev. F 06/2011

This manual is part of a set of three supporting this product.

Refer to manual 506017-02 for Care and Operation information

and 506019-40 for Facade Installation Instructions.
Ce manuel est disponible en francais, simplement

en faire la demande. Numéro de la pièce 506223-05.

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.
INSTALLATEUR : Laissez cette notice avec l'appareil.

CONSOMMATEUR : Conservez cette notice pour

consultation ultérieure.

Report No. 100353019PRT-002

AVERTISSEMENT : Assurez-vous de bien suivre les

instructions données dans cette notice pour réduire au

minimum le risque d’incindie ou d’explosion ou pour

éviter tout dommage matériel, toute blessure ou la mort.

WARNING: If the information in these instructions

is not followed exactly, a fire or explosion may

result, causing property damage, personal injury,

or death.

WARNING /AVERTISSEMENT/AVISO

• HOT GLASS WILL CAUSE

BURNS.

• DO NOT TOUCH GLASS

UNTIL COOLED.

• NEVER ALLOW CHILDREN

TO TOUCH GLASS.

• UNE SURFACE VITRÉE CHAUDE

PEUT CAUSER DES BRÛLURES.

• LAISSER REFROIDIR LA SURFACE

VITRÉE AVANT D'Y TOUCHER.

• NE PERMETTEZ JAMAIS À UN ENFANT

DE TOUCHER LA SURFACE VITRÉE.

• EL VIDRIO CALIENTE

CAUSARÁ QUEMADURAS.

• USTED DEBE NUNCA

TOCAR EL VIDRIO CALIENTE.

• LOS NIÑOS DEBEN NUNCA

TOCAR EL VIDRIO.

- Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any other

appliance.

- WHAT TO DO IF YOU SMELL GAS:

• Do not t

ry to light any appliance.

• Do not touch any electrical switch; do not use any

phone in your building.

• Immediately call your gas supplier from a

neighbor’

s phone. Follow the gas supplier

’s

instructions.

• If you cannot reach your gas supplier, call the fire

department.
- Installation and service must be performed by a

qualified installer, service agency or the gas supplier.

- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs

ou liquides inflammables dans le voisinage de cet appareil

ou de tout autre appareil.

- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :

• Ne pas tenter d’allumer d’appareil.

• Ne touchez à aucan interrupteu

r. Ne pas vous servir des

téléphones se trouvant dans le bâtiment où vous trouvez.

• Appelez immédiatement votre fournisseur de gaz depuis

un voisin. Suivez les instructions du fournisseur.

• Si vous ne pouvez rejoindre le fournisseur de gaz,

appelez le service des incindies.
-

L

’installation et l’entretien doivent être assurés par un

installateur ou un service d’entretien qualifié ou par le

fournisseur de gaz.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TABLE OF CONTENTS; Please read and understand these; WARNING; GENERAL INFORMATION; LENNOX HEARTH PRODUCTS • MERIT

2 TABLE OF CONTENTS Packaging .........................................Page 2Introduction ......................................Page 2General Information ..........................Page 2Requirements for the Commonwealth of Massachusetts .Page 4New York City Approval .....................Page 4Cold C...

Page 3 - Table 1; 0 - latest edition, or the Canadian Electrical

3 Input (BTU/HR) Manually-Modulated Gas Valves (all models) Models Input Rate (BTU / HR) Nat. Gas Prop. Gas MLDVTCD-35 14,500 high 11,500 low 13,500 high 10,500 low Table 1 The appliance, when installed, must be electri- cally grounded and wired in accordance with local codes or, in the absence of l...

Page 4 - Figure 1; SIT Millivolt Gas Valve; Table 4; Tables 2 and 3; less; Table; REQUIREMENTS FOR THE COMMON-

4 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Inlet Gas Supply Pressure (all models) Fuel # Minimum Maximum Natural Gas 4.5" WC (1.12 kPa) 10.5" WC (2.61 kPa) Propane 11.0" WC (2.74 kPa) 13.0" WC (3.23 kPa) Table 2 Manifold Gas Supply Pressure (all models) Fuel # Low High Na...

Other Lennox Models

All Lennox Other