- Page 2 – TABLE OF CONTENTS; Please read and understand these; WARNING; GENERAL INFORMATION; LENNOX HEARTH PRODUCTS • MERIT
- Page 3 – Table 1; 0 - latest edition, or the Canadian Electrical
- Page 4 – Figure 1; SIT Millivolt Gas Valve; Table 4; Tables 2 and 3; less; Table; REQUIREMENTS FOR THE COMMON-
- Page 5 – Figure 3; Typical Locations; HORIZONTAL VENT; When the unit is installed with one; COLD CLIMATE INSULATION; LOCATION; Do not insulate the space between the ap-
- Page 6 – Figure 4B; VENT TERMINATION CLEARANCES; These instructions should be used as a; Vertical Vent Termination Clearances; Figure 4A; Figure 5; Figure 5; Horizontal Vent Termination Clearances; Side Elevation View; Termination Heights For Vents; Figure 4A - Multiple Terminations
- Page 7 – ExTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS; Figure 6
- Page 8 – MINIMUM CLEARANCES TO COMBUSTIBLES; When the; Table 5; on the underside of the mantel.
- Page 9 – DETAILED INSTALLATION STEPS; Glass Panels on; Figures; on; Table 5 on Page 8; DO NOT; TYPICAL INSTALLATION SEQUENCE; Figure 47 on Page; Attach Safety in Operation
- Page 10 – FIREPLACE AND FRAMING SPECIFICATIONS; Vertical Venting Through the Ceiling:; Frame ceiling opening; Framing; Front View
- Page 11 – FIREPLACE FRAMING SPECIFICATIONS; Table 6; Corner Framing with Horizontal Termination; mm; Step 2. ROUTING GAS LINE; Proper Sizing of Gas Line
- Page 12 – Figure; Approved Vent Components
- Page 13 – Note: Convert inches into metric equivalent; Model; Table 7
- Page 14 – refer to Figure 17)
- Page 15 – Swivel Joint
- Page 16 – rate sections of concentric flexible; VERTICAL VENT FIGURES/TABLES; vent will be required.
- Page 17 – Ceiling; Top Vent - THREE ELBOWS
- Page 19 – Termination Guard; INSTALLING HORIZONTAL TERMINATION; Venting Connection and Exterior Wall Recessing; See; Table 8
- Page 20 – Under no circumstances, may separate sections of; HORIZONTAL VENT FIGURES/TABLES; Typical termination shown.; Termination Kit Only; zontal vent run is needed, then
- Page 22 – See Table 8 on Page 20 as
- Page 23 – SECuRE FLEXTM
- Page 24 – CAUTION; Verify proper operation after servicing.
- Page 25 – No batteries to be installed in the battery; BLOWER CONTROL CIRCUIT WIRING; WIRING - OPTIONAL FORCED AIR; Blower Access
- Page 26 – external to the appliance between the appliance; Step 6. CONNECTING GAS LINE; Gas
- Page 27 – Never use an open flame to check; Step 7. VERIFYING APPLIANCE; Page; Millivolt Appliance Checkout; Never use an open flame to
- Page 28 – Step 8. INSTALLING CONTEMPORARY; Turn off all electricity to the appliance; Remove the front glass enclosure panel
- Page 29 – MLDVTCD-35 REFRACTORY PANELS AND CONTEMPORARY MEDIA PLACEMENT
- Page 30 – ) by sliding and pulling the
- Page 31 – Burner Air Shutter Adjustment Procedure; Main Burner Factory Air Shutter; Figure 45 - Burner Air Shutter Adjustment
- Page 32 – FINISHING REQUIREMENTS - Contemporary Facade; (use the framing dimensions as-is as shown in; HOOD INSTALLATION; See Page 5 for Cold Climate Insulation; - Combustible Wall Framing; Figure 48 - Contemporary Facade Dimensions; Floor
- Page 33 – COLOCACIóN DE ADVERTENCIAS DE; ) o en el termostato; LENNOx HEARTH PRODUCTS; WARNINGS; ) and if used on the; LENNOx HEARTH PRODUCTS; Figure A
- Page 34 – INSTALLATION ACCESSORIES; ir
- Page 35 – INSTALLATION ACCESSORIES CONTINUED; lf
- Page 36 – Millivolt; this installation assumes responsibility for this conversion.; AVERTISSEMENT; assume les responsabilités liées à la conversion.; Burner Assembly
- Page 37 – Millivolt Appliances; Pressure; VERIFY THE PROPER ORIFICE SIZE; Table 9; - Dexen Electronic Gas Valve
MODELS
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases unless a certified kit is used.
INSTALLATION INSTRUC
TIONS
™
MLDVTCD Direct-Vent
Contemporary Design
Gas Fireplaces
MLDVTCD-35NM
MILLIVOLT:
MLDVTCD-35NE
ELECTRONIC:
P/N 506015-03 Rev. F 06/2011
This manual is part of a set of three supporting this product.
Refer to manual 506017-02 for Care and Operation information
and 506019-40 for Facade Installation Instructions.
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 506223-05.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR : Laissez cette notice avec l'appareil.
CONSOMMATEUR : Conservez cette notice pour
consultation ultérieure.
Report No. 100353019PRT-002
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d’incindie ou d’explosion ou pour
éviter tout dommage matériel, toute blessure ou la mort.
WARNING: If the information in these instructions
is not followed exactly, a fire or explosion may
result, causing property damage, personal injury,
or death.
WARNING /AVERTISSEMENT/AVISO
• HOT GLASS WILL CAUSE
BURNS.
• DO NOT TOUCH GLASS
UNTIL COOLED.
• NEVER ALLOW CHILDREN
TO TOUCH GLASS.
• UNE SURFACE VITRÉE CHAUDE
PEUT CAUSER DES BRÛLURES.
• LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
• NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
• EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
• USTED DEBE NUNCA
TOCAR EL VIDRIO CALIENTE.
• LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS:
• Do not t
ry to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor’
s phone. Follow the gas supplier
’s
instructions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteu
r. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
-
L
’installation et l’entretien doivent être assurés par un
installateur ou un service d’entretien qualifié ou par le
fournisseur de gaz.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 TABLE OF CONTENTS Packaging .........................................Page 2Introduction ......................................Page 2General Information ..........................Page 2Requirements for the Commonwealth of Massachusetts .Page 4New York City Approval .....................Page 4Cold C...
3 Input (BTU/HR) Manually-Modulated Gas Valves (all models) Models Input Rate (BTU / HR) Nat. Gas Prop. Gas MLDVTCD-35 14,500 high 11,500 low 13,500 high 10,500 low Table 1 The appliance, when installed, must be electri- cally grounded and wired in accordance with local codes or, in the absence of l...
4 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Inlet Gas Supply Pressure (all models) Fuel # Minimum Maximum Natural Gas 4.5" WC (1.12 kPa) 10.5" WC (2.61 kPa) Propane 11.0" WC (2.74 kPa) 13.0" WC (3.23 kPa) Table 2 Manifold Gas Supply Pressure (all models) Fuel # Low High Na...