Table of Contents:
- Page 2 – Figure 1; TABLE OF CONTENTS
- Page 3 – Table 3; Table 3 shows the gas orifice size required; Table 1; Input; Table 2; * If field converted to propane
- Page 4 – Requirements for the Commonwealth of Massachusetts; and national codes not contained in this document.
- Page 5 – See; APPLIANCE AND VENT CLEARANCES; LOCATION; Figure 2; Typical Locations; Table 5; Combustible Shelf Height; Top Vent - with 2 Feet Vertical Vent; * Includes ” clearance to combustibles; WARNING; Figure 3; WARNING; Surveiller les enfants. Garder les
- Page 6 – Figure 6; Right Side; Horizontal Vent Termination Clearances; Unit Being Secured by Its Nailing; Figure 5 - Side Elevation View; Termination Heights For Vents
- Page 7 – EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS; Minimum Clearances
- Page 8 – Back wall of chase/enclosure; Figure 9; FIREPLACE FRAMING SPECIFICATIONS; Framing should be constructed
- Page 9 – Gas Inlet; Model; Unit Dimensions; FIREPLACE SPECIFICATIONS
- Page 10 – VENT RESTRICTOR INSTALLATION; Figure 4
- Page 12 – Connection; Figure 18 on; Proper venting support is very important.
- Page 13 – Maximum; VERTICAL VENT FIGURES/TABLES; Page 6; Secure Vent
- Page 14 – Ceiling
- Page 15 – TYPICAL HORIZONTAL VENT INSTALLATION; Figure 8
- Page 16 – Figure; Venting Connection and Exterior Wall Recessing
- Page 17 – Table 6; HORIZONTAL VENT FIGURES/TABLES; Two 45 degree elbows may be used in place of one 90 degree
- Page 19 – CAUTION; Figures 32A and; ELECTRONIC; See Figure 11 on Page 9.; CONTROL CIRCUIT WIRING; See Figure 32B for detailed; drawing of junction box /
- Page 20 – Gas; Flare Fitting; Gas Flex Line Connector; Trap; LOGS AND GLOWING EMBERS; refer to; Test all connections for gas leaks
- Page 21 – INSTALLING THE GLASS DOOR; Flame Appearance and sooting; TION; Lighting Instructions are also found on; Millivolt Appliance Checkout; Step 9. INSTALLING THE GLASS DOOR; Electronic Appliance Checkout
- Page 22 – Air shutter adjustment should; Burner Adjustment; FINISHING REQUIREMENTS
- Page 23 – to; It is critical that there is at least a
- Page 24 – MANTEL CLEARANCES; COLD CLIMATE INSULATION; Description
- Page 26 – Burner Assembly; GAS CONVERSION KITS
- Page 27 – Millivolt & Electronic Gas Valves; Millivolt & Electronic Pilot Assemblies; Table 7
This appliance may be installed in an aftermarket
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes. This appliance is only for use with
the type of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
In the Commonwealth of Massachusetts:
•
Installation must be performed by a licensed plumber or
gas fitter;
• See Table of Contents for location of additional Com-
monwealth of Massachusetts requirements.
FOR YOUR SAFETY: Do not store or use gasoline
or other flammables or liquids in the vicinity of
this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow your gas suppliers
instructions.
• If your gas supplier cannot be reached, call
the fire department.
Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni
utiliser d'essence ni d'autre vapeurs ou liquides
inflammables dans le voisinage de cet appareil ou
de tout autre appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez
une odeur de gaz:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bati-
ment où vous vous trouvez.
• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de
gaz, appelez le service dos incendies.
L'installation et service doit être exécuté par un
qualifié installeur, agence de service ou le fournis-
seur de gaz.
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN
SUIVRE LES INSTRUCTIONS DONNÉ DANS CETTE
NOTICE POUR RÉDUIRE AU MINIMUM LE RISQUE
D'INCENDIE OU POUR ÉVITER TOUT DOMMAGE
MATÉRIEL, TOUTE BLESSURE OU LA MORT.
INSTALLATION
INSTRUCTIONS
MODELS
OTL Report No. 116-F-22-5
DIRECT
VENT
MONTEBELLO™
VENTED GAS FIREPLACE - DIRECT VENT MODELS
P/N 850,026M REV. D 08/2007
A French manual is available upon request. Order P/N 850,026CF
Ce manuel d’installation est disponible en francais, simplement
en faire la demande. Numéro de la pièce 850,026CF.
US
TM
Millivolt Models
Electronic Models
LSM40MN-2
LSM40EN-2
LSM40MP-2
LSM45EN-2
LSM45MN-2
LSM45MP-2
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Drywall Top Of Fireplace Opening Non-Combustible Figure 1 TABLE OF CONTENTS Packaging .........................................Page 2Introduction ......................................Page 2General Information ..........................Page 2New...
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Model Orifice Size Elevation Feet (meters) Nat. Prop. LSM40-2 .1405" (#28) .086" (#44) 0-4500 (0-172) LSM45-2 .161" (#20) .09" (#42) Table 3 The millivolt appliances are manually controlled and feature a spark igniter (piezo) that ...
4 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. New York City, New York (MEA) Installation of these fireplaces are approved for installation in New York City in the US state of New York. Requirements for the Commonwealth of Massachusetts Note: The following requirements reference various Mass...