Lennox LMDVR-3328-CPM - Manual
Lennox LMDVR-3328-CPM – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – TABLE OF CONTENTS; INTRODUCTION; Manufactured Home Requirements; PACKAGING; WARNING; GENERAL INFORMATION; Millivolt; Please read and understand these
- Page 3 – Series; Table 7; by closing their; Flame Height
- Page 4 – COLD CLIMATE INSULATION; Figure 4; Typical Locations; LOCATION
- Page 5 – VENT TERMINATION CLEARANCES; Figure 5; Horizontal Vent Termination Clearances; Figure 6; MANUFACTURED HOME; CAUTIONS; Termination Heights For Vents; Side Elevation View
- Page 6 – EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS; Figure 7; = Area where Terminal is not Permitted
- Page 7 – MINIMUM CLEARANCES TO COMBUSTIBLES; Table 8
- Page 8 – Pressure Relief Plates; TYPICAL INSTALLATION SEQUENCE; Figure; DETAILED INSTALLATION STEPS; Control Compartment Access / Louver Panel
- Page 9 – FIREPLACE SPECIFICATIONS; Vertical Venting Through the Ceiling:; Frame ceiling opening; of 2x4 or larger lumber; Framing; Top View
- Page 10 – FIREPLACE FRAMING SPECIFICATIONS; Table 9; Proper Sizing of Gas Line
- Page 11 – Approved Vent Components; on
- Page 12 – Model; See Figure 20 on Page 12 and Figures 28-
- Page 14 – VERTICAL VENT FIGURES/TABLES; rate Sections of Concentric Flexible
- Page 15 – Maximum; Ratio V to H ratio is 1:2; A Vent Restrictor, as shown in
- Page 16 – Top Vent - THREE ELBOWS
- Page 18 – For thicknesses greater; IMPORTANT; Termination Guard
- Page 19 – When using Secure Flex,; Under no circumstances, may separate sections of; HORIZONTAL VENT FIGURES/TABLES; Square termination; Termination Kit and 6 In. Vent
- Page 20 – See Table 12 on Page 19 as an aid in venting component
- Page 22 – SECuRE FLEX
- Page 23 – Step 4. FIELD WIRING; WIRING - OPTIONAL FORCED AIR; See; CAUTION; Millivolt Wiring Diagram; TP
- Page 24 – Schematic Representation Only; Gas; Gas Flex Line Connector; GAS CONNECTION; Step 6. CONNECTING GAS LINE; Secure all joints tightly using appropriate; ground screw located on the outlet box. See
- Page 25 – TEST ALL CONNECTIONS FOR GAS LEAKS; Never use an open flame to; CONTROL COMPARTMENT ACCESS /; can be found in the control compartment; SIT and Honeywell Millivolt Appliance
- Page 26 – Bag of Glowing; CANIC STONE, GLOWING EMBERS AND; Removing Glass Enclosure Panels; Electronic Appliance Checkout
- Page 27 – Log Placement Instructions; LOG SET; Description; DO NOT PLACE EMBERS OVER BuRNER SLOTS; shown here (1 through 6) and per the instructions on
- Page 29 – Step 9. INSTALLING THE GLASS DOOR; Ensure front glass panel are in; Reinstalling Control
- Page 30 – The air shutter door and nearby appliance surfaces are; Step 11. HOOD INSTALLATION; See Page 4 for Cold Climate Insulation; Burner Air Shutter Adjustment Procedure; Combustible Wall Framing
- Page 31 – INSTALLATION ACCESSORIES; The following flashings come packaged with a storm collar:; Through Wall Shield Kit; Termination Shroud (Guard) for Horizontal Square Termination
- Page 32 – Open Top, Chase Top Shroud; All compressed flex vents can be; Arch Top, Chase Top Shroud
- Page 33 – Horizontal Small Square Termination without flex vent
- Page 34 – GAS CONVERSION KITS
- Page 35 – La conversion devra être effectuée; Note - use extra care not to engage the; NA
- Page 36 – drill
This appliance may be installed in an aftermarket
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes. This appliance is only for use with
the type of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
In the Commonwealth of Massachusetts:
•
Installation must be performed by a licensed plumber or
gas fitter;
• See Table of Contents for location of additional Com-
monwealth of Massachusetts requirements.
Do not store or use gasoline or other flammable
vapors or liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS:
• Do not light any appliance.
• Do not touch any electrical switch; do not
Use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow your gas supplier's
instructions.
• If your gas supplier cannot be reached, call
the fire department.
Installation and service must be performed by
a qualified installer, service agency or the gas
supplier
.
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni
utiliser d'essence ni d'autre vapeurs ou liquides
inflammables dans le voisinage de cet appareil ou
de tout autre appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez
une odeur de gaz:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bati-
ment où vous vous trouvez.
• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de
gaz, appelez le service dos incendies.
L'installation et service doit être exécuté par un
qualifié installeur, agence de service ou le fournis-
seur de gaz.
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN
SUIVRE LES INSTRUCTIONS DONNÉ DANS CETTE
NOTICE POUR RÉDUIRE AU MINIMUM LE RISQUE
D'INCENDIE OU POUR ÉVITER TOUT DOMMAGE
MATÉRIEL, TOUTE BLESSURE OU LA MORT.
INSTALLATION
INSTRUCTIONS
MODELS
LMDVT-3328-CNM
LMDVT-3328-CPM
LMDVR-3328-CNM
LMDVR-3328-CPM
LMDVT-3328-CNE
LMDVR-3328-CNE
LMDV-3530-CNE
LMDV-4035-CNE
OTL Report No. 116-F-31-5
Millivolt Models
Electronic Models
LMDV-3530-CNM
LMDV-3530-CPM
LMDV-4035-CNM
LMDV-4035-CPM
DIRECT
VENT MERIT
™
LMDV-33/35/40 SERIES
P/N 850,029M REV. G 05/2008
VENTED GAS FIREPLACE HEATERS - DIRECT VENT MODELS
A French manual is available upon request. Order P/N 850,029CF
Ce manuel d’installation est disponible en francais, simplement en
faire la demande. Numéro de la pièce 850,029CF.
US
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 2 TABLE OF CONTENTS Packaging .........................................Page 2 Introduction ......................................Page 2 General Information ..........................Page 2 New York City Approval .....................Page 3 Require...
3 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Electronic Models - Electronic models have a fixed rate gas valve. Input of electronic models is shown in Table 3. Electronic Models with Fixed Rate Gas Valve Natural and Propane Gas Model Series Input Rate (BTU / HR) LMDVT-3328 LMDVR-3328 17,50...
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 4 Massachusetts And New York City, NY Re- quirements These appliances are approved for installation in the following USA locations listed in the following: Massachusetts: These fireplaces are approved for installation in the US state of Massachuse...