Lennox L30 DVF-2 - Manual

Lennox L30 DVF-2

Lennox L30 DVF-2 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
Page: / 29

Table of Contents:

  • Page 3 – TABLE OF CONTENTS; APPROVED VENT BRANDS:
  • Page 4 – PLANNING YOUR INSTALLATION; In; Pressure Testing
  • Page 5 – PAGE 5; QUESTIONS TO ASK THE LOCAL BUILDING OFFICIAL; In some states or municipalities, a licensed gas fitter or
  • Page 6 – CLEARANCES TO COMBUSTIBLE MATERIALS
  • Page 7 – INSTALLATION; PAGE 7; See page 10 for; Vent Termination Requirements.
  • Page 8 – PAGE 8; VENT RESTRICTOR RING INSTALLATION; Flame appears yellow with black tips.; Symptoms - Excessive Combustion Air; Pilot pulls and appliance shuts down.
  • Page 9 – DIRECT VENT SYSTEM COMPONENTS – Model L30 DVF-2
  • Page 10 – DIRECT VENT RETROFIT OF EXISTING CHIMNEY SYSTEM; SV4MCK; Termination Heights For Vents Above Flat or Sloped Roofs
  • Page 11 – HORIZONTAL VENT TERMINATION REQUIREMENTS; B = 12” Clearance to window or door that may be
  • Page 12 – GAS SUPPLY HOOKUP; In case emergency shut-off is required, shut off; Supply Line Size Requirements; Suggested Sizing of; Schedule 40 Pipe
  • Page 13 – DOOR OPERATION; Remove the glass door assembly from appliance as fol-
  • Page 14 – GAS APPLIANCE FINAL ASSEMBLY; Door Assembly; The quantity and placement of the ember
  • Page 15 – INSTALLATION CHECK LIST
  • Page 16 – CARE AND OPERATION; Gas Control Knobs; Circulation Blower Operation; TO TURN OFF GAS TO THE APPLIANCE
  • Page 17 – Small Area Paint Touch-Up; Variable Speed Control for Air Circulation Blower
  • Page 18 – PROPANE CONVERSION; Installation Tools / Supplies; Propane RB Regulator conversion screw (Red indicates LP gas); PROPANE Conversion Procedure; If you are at an elevation above 4500 feet, do not use the; Burner Flame Appearance
  • Page 19 – BURNER FLAME APPEARANCE; Burner Flame App
  • Page 20 – Installing Log Set
  • Page 21 – Cycle unit a minimum of 2 times; Watch for smooth burner ignition and shut down.; PILOT FLAME APPEARANCE; Burner Air Shutter
  • Page 22 – WIRING DIAGRAMS; GAS CONTROL AND SAFETY SYSTEM WIRING DIAGRAM; Thermocouple
  • Page 23 – TROUBLESHOOTING; Qualified Technicians Only; PROBLEM; Cleaning; REFERENCE INFORMATION FOR QUALIFIED TECHNICIAN:
  • Page 24 – REPLACEMENT PARTS
  • Page 25 – OPTIONAL ACCESSORIES; Description
  • Page 28 – OWNERSHIP RECORDS; Date of Purchase: Date; SERVICE AND MAINTENANCE LOG; Service Service
Loading the manual

I N S T A L L A T I O N A N D O P E R A T I O N

M A N U A L








































FREESTANDING VENTED GAS FIRED ROOM HEATERS

RETAIN THIS MANUAL FOR FUTURE REFERENCE

P/N 775,029M Rev. B, 8/04

Model: L30 DVF-2 (Direct-Vent)

This appliance may be installed in an aftermarket permanently located,

manufactured (mobile) home, where not prohibited by local codes

Report No. 189122-1050009

WARNING: IF THE INFORMATION IN
THIS MANUAL IS NOT FOLLOWED EX-
ACTLY, A FIRE OR EXPLOSION MAY
RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.

FOR YOUR SAFETY: Do not store or use gaso-

line or other flammable vapors or liquids in the

vicinity of this or any other appliance.

FOR YOUR SAFETY: What to do if you smell gas:

• DO NOT light any appliance.

• DO NOT touch any electrical switches.

• Do not use any phone in your building.

• Immediately call your gas supplier from

a neighbor’s phone. Follow your gas

suppliers instructions.

• If your gas supplier cannot be reached, call

the fire department.

Installation and service must be performed

by a qualified installer, service agency or

the gas supplier.

AVERTISSEMENT: ASSUREZ-VOUS DE BIEN
SUIVRE LES INSTRUCTIONS DONNÉ DANS CETTE
NOTICE POUR RÉDUIRE AU MINIMUM LE RISQUE
D’INCENDIE OU POUR ÉVITER TOUT DOMMAGE
MATÉRIEL, TOUTE BLESSURE OU LA MORT.

POUR VOTRE SÉCURITÉ: Ne pas entreposer ni

utiliser d’essence ni d’autre vapeurs ou liquides

inflammables dans le voisinage de cet appareil ou

de tout autre appareil.

POUR VOTRE SÉCURITÉ: Que faire si vous sentez

une odeur de gaz:

• Ne pas tenter d’allumer d’appareil.

• Ne touchez à aucun interrupteur. Ne pas vous

servir des téléphones se trouvant dans le batiment

où vous vous trouvez.

• Evacuez la piéce, le bâtiment ou la zone.

• Appelez immédiatement votre fournisseur de gaz

depuis un voisin. Suivez les instructions du

fournisseur.

• Si vous ne pouvez rejoindre le fournisseur de gaz,

appelez le service dos incendies.

L’installation et service doit être exécuté par un qualifié

installeur, agence de service ou le fournisseur de gaz.

Shown with optional gold door and brickaded interior

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - TABLE OF CONTENTS; APPROVED VENT BRANDS:

TABLE OF CONTENTS PAGE 3 Important Warnings ........................................................ 2 Testing / Listing, Using this Manual ................................. 3 Planning Your Installation .............................................. 4-6 Manufactured (Mobile) Home Installation..........

Page 4 - PLANNING YOUR INSTALLATION; In; Pressure Testing

PLANNING YOUR INSTALLATION PAGE 4 LOCAL AND NATIONAL CODE REQUIREMENTS The installation of these appliances must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, (for USA) NFPA 54 / ANSI Z223.1-latest edition. Air Circulation Blower: The blower electrical ...

Page 5 - PAGE 5; QUESTIONS TO ASK THE LOCAL BUILDING OFFICIAL; In some states or municipalities, a licensed gas fitter or

PLANNING YOUR INSTALLATION PAGE 5 QUESTIONS TO ASK THE LOCAL BUILDING OFFICIAL Correct installation is critical and imperative for reducing fire hazards and perilous conditions that can arise when gas appli-ances function improperly. The appliance must be installed per manufacturers’ instructions. G...