Lennox L20 BF-2 - Manual
Lennox L20 BF-2 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – PAGE 2
- Page 3 – TABLE OF CONTENTS; PAGE 3; PACKAGING LIST
- Page 4 – PLANNING YOUR INSTALLATION; PAGE 4; Phillips head screw driver.; See
- Page 5 – PAGE 5; QUESTIONS TO ASK THE LOCAL BUILDING OFFICIAL; In some states or municipalities, a licensed gas fitter or
- Page 6 – Rear Wall or Alcove
- Page 7 – PAGE 7; See page 10 for; Vent Termination Requirements.
- Page 8 – INSTALLATION; DIRECT VENT SYSTEM COMPONENTS – MODEL L20 DVF-2 ONLY; PAGE 8
- Page 9 – MODEL L20 DVF-2 ONLY; PAGE 9; Direct Vent Retrofit Of Existing Chimney System; SV4MCK
- Page 10 – D = 24” Vertical clearance to ventilated soffit located above the
- Page 11 – B-Vent Installation Illustration; Approved for vertical termination only.; Maximum Horizontal Pipe Runs
- Page 12 – In case emergency shut-off is required, shut off; Supply Line Size Requirements; Suggested Sizing of; Schedule 40 Pipe
- Page 13 – forward until bottom of door releases.
- Page 14 – GAS APPLIANCE FINAL ASSEMBLY (ALL MODELS); Carefully place the largest log in the rear of the firebox as; Glowing Embers
- Page 15 – “Break In” Period
- Page 16 – CARE AND OPERATION; Gas Control Knobs; Circulation Blower Operation; TO TURN OFF GAS TO THE APPLIANCE; Pilot Assembly
- Page 17 – Small Area Paint Touch-Up
- Page 18 – PROPANE CONVERSION; Installation Tools / Supplies; Propane RB Regulator conversion screw (Red indicates LP gas); PROPANE Conversion Procedure; If you are at an elevation above 4500 feet, do not use the; Burner Flame Appearance
- Page 19 – REFERENCE INFORMATION; Burner Flame App
- Page 20 – Installing Log Set
- Page 21 – Cycle unit a minimum of 2 times; Watch for smooth burner ignition and shut down.; PILOT FLAME APPEARANCE; Burner Air Shutter
- Page 22 – WIRING DIAGRAMS; GAS CONTROL AND SAFETY SYSTEM WIRING DIAGRAM
- Page 23 – TROUBLESHOOTING; Qualified Technicians Only; PROBLEM; Spill Switch; REFERENCE INFORMATION FOR QUALIFIED TECHNICIAN:
- Page 24 – Troubleshooting Check List (Qualified Technicians Only); Rear Access Panel
- Page 27 – SPECIFICATIONS; stove face to alcove opening
- Page 31 – Service Service
I N S T A L L A T I O N A N D O P E R A T I O N
FREESTANDING VENTED GAS FIRED ROOM HEATERS
RETAIN THIS MANUAL FOR FUTURE REFERENCE
P/N 775,021M Rev. C, 8/04
Models: L20 BF-2 (B-Vent) and L20 DVF-2 (Direct-Vent)
Model L20 DVF-2 may be installed in an aftermarket permanently located,
manufactured (mobile) home, where not prohibited by local codes
Report #189122-1027389
WARNING: IF THE INFORMATION IN THIS MAN-
UAL IS NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY: Do not store or use gasoline
or other flammable vapors or liquids in the vicin-
ity of this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• Do not use any phone in your building.
• Immediately call your gas supplier from
a neighbor’s phone. Follow your gas
suppliers instructions.
• If your gas supplier cannot be reached, call
the fire department.
Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE LES
INSTRUCTIONS DONNÉ DANS CETTE NOTICE POUR
RÉDUIRE AU MINIMUM LE RISQUE D’INCENDIE OU
POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE
BLESSURE OU LA MORT.
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni utiliser
d’essence ni d’autre vapeurs ou liquides inflammables dans
le voisinage de cet appareil ou de tout autre appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez une
odeur de gaz:
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucun interrupteur. Ne pas vous
servir des téléphones se trouvant dans le batiment
où vous vous trouvez.
• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz, appe-
lez le service dos incendies.
L’installation et service doit être exécuté par un qualifié
installeur, agence de service ou le fournisseur de gaz.
L20 DVF-2 shown with optional gold door and brickaded interior
M A N U A L
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
IMPORTANT WARNINGS / CAUTIONS CAUTION: READ THIS MANUAL THOROUGHLY BEFORE STARTING INSTALLATION. FOR YOUR SAFETY, FOLLOW THE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EXACTLY WITHOUT DE-VIATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN A POSSIBLE FIRE HAZARD AND MAY VOID THE WAR...
TABLE OF CONTENTS PAGE 3 Important Warnings ........................................................ 2 Testing / Listing, Using this Manual ................................. 3 Planning Your Installation .............................................. 4-6 Manufactured (Mobil) Home Requirements...........
PLANNING YOUR INSTALLATION PAGE 4 LOCAL AND NATIONAL CODE REQUIREMENTS The installation of these appliances must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, (for USA) NFPA 54 / ANSI Z223.1 - latest edition. Air Circulation Blower: The blower electrica...