Lennox G24-200 - Manual
Lennox G24-200 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – FRONT VIEW
- Page 3 – G24−200 Filter Box Dimensions − inches (mm); BACK VIEW
- Page 5 – G24−200 Parts Arrangement Continued
- Page 6 – WARNING
- Page 8 – General; Product contains fiberglass wool.; CAUTION; Combustion Air Requirements
- Page 9 – Unconfined Space
- Page 11 – Setting Equipment; Return Air Plenum / Filter Box Installation
- Page 12 – − Install the filters and the filter access door.; SIDE VIEW; BOTTOM RETURN AIR FILTER BOX INSTALLATION; FIGURE 5
- Page 14 – FORCE; Venting
- Page 15 – IMPORTANT; COMMON VENTING USING METAL−LINED MASONRY CHIMNEY; FIGURE 9
- Page 22 – CARBON MONOXIDE POISONING HAZARD!
- Page 23 – for appliances
- Page 25 – Gas Piping; Left-Side Installation −; RIGHT SIDE GAS LINE INSTALLATION; (See item # 1 on previous page for installation instructions)
- Page 26 – Leak Check; FIRE OR EXPLOSION HAZARD
- Page 27 – Electrical; DRIVE KIT TRANSFORMER VOLTAGES AND PART NUMBERS
- Page 31 – SCHEMATIC WIRING DIAGRAM FOR G24−200 UNITS (120V SINGLE PHASE 60HZ )
- Page 32 – WIRING SCHEMATIC DIAGRAM FOR G24−200
- Page 33 – Unit Start−Up; SMOKE POTENTIAL
- Page 34 – Heating Sequence of Operation
- Page 35 – Gas Pressure Adjustment; corrections in altitudes above 2000 ft.; High Altitude Information
- Page 37 – Setting blower CFM; Blower RPM adjustment is accomplished by
- Page 40 – Troubleshooting; HEATING SEQUENCE OF OPERATION WITH TWO-STAGE THERMOSTAT; NORMAL HEATING MODE
- Page 41 – LED CODES
- Page 42 – HEATING SEQUENCE OF OPERATION WITH SINGLE-STAGE THERMOSTAT
- Page 44 – FOR TWO CONDENSING UNITS; MANUAL FAN OPERATION
503,613M
*P504613M*
08/05
*2P0805*
PRODUCT LITERATURE
2005 Lennox Industries Inc.
Dallas, Texas
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
INSTALLATION
INSTRUCTIONS
G24-200
UPFLOW GAS FURNACE
Direct Spark Ignition
503,613M
8/2005
Supersedes 7/2003
Table of Contents
G24−200 Unit Dimensions
2
. . . . . . . . . . . . . . . . . . . . . .
G24−200 Parts Arrangement
4
. . . . . . . . . . . . . . . . . . . .
G24−200 Gas Furnace
6
. . . . . . . . . . . . . . . . . . . . . . . . .
Shipping and Packing List
6
. . . . . . . . . . . . . . . . . . . . . .
Safety
6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General
8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Combustion, Dilution & Ventilation Air
8
. . . . . . . . . . . .
Setting Equipment
11
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Return Air Plenum / Filter Box Installation
11
. . . . . . . .
Duct System
13
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Blower Motor and Drive Installation
13
. . . . . . . . . . . . .
Venting
14
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Gas Piping
25
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical
27
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Unit Start−up
33
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Heating Sequence of Operation
34
. . . . . . . . . . . . . . . .
Gas Pressure Adjustment
35
. . . . . . . . . . . . . . . . . . . . .
High Altitude Information
35
. . . . . . . . . . . . . . . . . . . . . .
Other Unit Adjustments and Operation
35
. . . . . . . . . . .
Setting Blower CFM
37
. . . . . . . . . . . . . . . . . . . . . . . . . .
Repair Parts List
39
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
G24−200 Start−up & Performance Check List
39
. . . . .
Troubleshooting
40
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
Installation and service must be per-
formed by a qualified installer, ser-
vice agency or the gas supplier.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Extinguish any open flame.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas suppli-
er’s instructions.
If you cannot reach your gas supplier, call
the fire department.
Leave the building immediately.
FIRE OR EXPLOSION HAZARD.
Failure to follow safety warnings exact-
ly could result in serious injury, death,
or property damage.
WARNING
Litho USA
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Page 2 G24−200 Unit Dimensions − inches (mm) 10-1/2 (267) 17 (432) 52-1/2 (1334) 53 (1346) 9 (229) Either Side 29-1/4 (743) 17 (432) 4-1/4 (108) Either Side 5-1/2(140) VENT OUTLETS GAS PIPING INLET Either Side) HEAT EXCHANGER BLOWER MOTOR ELECTRICAL INLET (Either Side) FRONT VIEW SIDE VIEW VENT OUTL...
Page 3 G24−200 Filter Box Dimensions − inches (mm) *OPTIONAL FILTER BOX BACK VIEW SIDE VIEW 32 (813) 1 (25) 4-3/4(121) 26-1/4 (667) 1 (25) 1 (25) 50-1/2 (1283) OPENING SAME BOTH SIDES 5 (127) *NOTE Return air filter box may beinstalled at back or bottom of furnace. AIR FLOW AIR FLOW 5 (127) 32 (813)...
Page 5 G24−200 Parts Arrangement Continued G24−200 BLOWER SECTION WHEEL BLOWER HOUSING CUT−OFF PLATE BEARING SHAFT BLOWER PULLEY MOTOR (Drive Kit) VIBRATION ISOLATOR BASE ASSEMBLY MOTOR BASE ADJUSTMENT ARM MOTOR BASE LOCATING ROD MOTOR PULLEY (Drive Kit) DRIVE BELT (Drive Kit)