Lennox ELDV-45NM - Manual
Lennox ELDV-45NM – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – TABLE OF CONTENTS; Please read and understand these; WARNING; GENERAL INFORMATION
- Page 4 – Table 4; Series; Table 5; REQUIREMENTS FOR THE COMMON-; Table 3; Table 2
- Page 5 – Figure 3; Typical Locations; HORIZONTAL VENT; When the unit is installed with one; LOCATION; Due to high temperatures, the appliance
- Page 6 – VENT TERMINATION CLEARANCES; Termination Heights For Vents; Figure 6; Side Elevation View; Minimum; Figure 4 - Multiple Terminations
- Page 7 – EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS; Figure 7
- Page 8 – Top Vent - with One 90 Degree Elbow; MINIMUM CLEARANCES TO COMBUSTIBLES; When the; Hearth Extension; Combustible wall finish materials and/or surround materials; Table 6
- Page 9 – DETAILED INSTALLATION STEPS; Figure 12 - Nailing Flanges; Figures; DO NOT; the 1/2” clearance to combustible requirements; TYPICAL INSTALLATION SEQUENCE
- Page 10 – FIREPLACE AND FRAMING SPECIFICATIONS; Frame ceiling opening; Framing
- Page 11 – Table 7; Proper Sizing of Gas Line; Figure 15 - Route Gas Line; Step 2. ROUTING GAS LINE
- Page 12 – Approved Vent Components; Exhaust Vent; Figure
- Page 13 – Note: Convert inches into metric equivalent; Effective Vent Length; Model; Table 8; Figures 25 through; Secure VentTM; Figure 5; on; Tables on this page
- Page 15 – Swivel Joint; Figure 22 - Roof Framing; Storm
- Page 16 – as shown in; be used in this; VERTICAL VENT FIGURES/TABLES; • Secure VentTM (rigid vent pipe) is shown; rate sections of concentric flexible; Note: Install a second; V M; vent will be required.
- Page 17 – Ceiling; Top Vent - THREE ELBOWS; Figures 31
- Page 18 – horizontal/inclined run be maintained in a
- Page 19 – tion Guard; INSTALLING HORIZONTAL TERMINATION; Venting Connection and Exterior Wall Recessing; Table 9; See
- Page 20 – HORIZONTAL VENT FIGURES/TABLES; • Secure VentTM components (rigid vent pipe and terminal) are shown; ELBOW CONNECTION NOT DIRECTLY AT APPLIANCE; Typical termination shown.; Venting Components Required for Various Exterior Wall Thick-; Termination Kit Only; zontal vent run is needed, then; Under no circumstances, may separate sections of
- Page 21 – Top Vent - TWO 90 DEGREE ELBOWS; See Table 9 on Page 20 as an aid in venting component selection for; When using Secure Flex,; Wall
- Page 22 – Section Required; ) horizontal run, up to a maximum horizontal; Top Vent - THREE 90 DEGREE ELBOWS
- Page 23 – SECuRE FLExTM
- Page 24 – Page; INTERMITTENT ELECTRONIC WIRING DIAGRAM; CAUTION; Verify proper operation after servicing.
- Page 25 – BLOWER CONTROL CIRCUIT WIRING; Junction Box; WIRING - OPTIONAL FORCED AIR; Blower Access
- Page 27 – Never use an open flame to; TION
- Page 28 – Glowing Embers; Bag of Glowing; Remove the front glass enclosure panel
- Page 29 – Catalog Number for the entire
- Page 31 – Catalog Number for the entire log
- Page 32 – ) by lifting and pulling the
- Page 33 – Move the adjustment rod down to; Burner Air Shutter Adjustment Procedure
- Page 34 – HOOD INSTALLATION; angled air plenum ramp above the opening above the door.; FINISHING REQUIREMENTS - Wall Details; framework to accommodate the thickness of the finished wall (; See Page 5 for Cold Climate Insulation
- Page 35 – COLOCACIóN DE ADVERTENCIAS DE; ) o en el termostato; LENNOX HEARTH PRODUCTS; WARNINGS; ). The warnings should already have been; LENNOX HEARTH PRODUCTS; Figure A
- Page 36 – rigid; INSTALLATION ACCESSORIES; Listed Secure VentTM Components
- Page 37 – INSTALLATION ACCESSORIES CONTINUED; All compressed flex vents can be expanded up to two times.
- Page 38 – this installation assumes responsibility for this conversion.; AVERTISSEMENT; assume les responsabilités liées à la conversion.
- Page 39 – Millivolt Appliances; ment kit is available, order Catalog Number; and replace the pilot orifice as; ELECTRONIC
OTL Report No. 116-F-39C-5
US
Portland
MODELS
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases unless a certified kit is used.
INSTALLATION INSTRUC
TIONS
™
ELDV Direct-Vent
Gas Fireplaces
ELDV-35NM
ELDV-40NM
ELDV-45NM
ELDV-35PM
ELDV-40PM
ELDV-45PM
MILLIVOLT:
ELDV-35NE
ELDV-40NE
ELDV-45NE
ELECTRONIC:
P/N 850036M Rev. H 01/2011
This manual is one of a set of two supporting this product.
Refer to P/N 875030M for Care and Operation Instructions.
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 850036CF.
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d’incindie ou d’explosion ou pour
éviter tout dommage matériel, toute blessure ou la mort.
- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L’installation et l’entretien doivent être assurés par un
installateur ou un service d’entretien qualifié ou par le
fournisseur de gaz.
WARNING: If the information in these instructions
is not followed exactly, a fire or explosion may
result, causing property damage, personal injury,
or death.
-
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
•
department.
- Installation and service must be performed by a
WARNING / AVERTISSEMENT / AVISO
• HOT GLASS WILL CAUSE
BURNS.
• DO NOT TOUCH GLASS
UNTIL COOLED.
• NEVER ALLOW CHILDREN
TO TOUCH GLASS.
• UNE SURFACE VITRÉE CHAUDE
PEUT CAUSER DES BRÛLURES.
• LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
• NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
• EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
• USTED DEBE NUNCA
TOCAR EL VIDRIO CALIENTE.
• LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
INSTALLATEUR :
Laissez cette notice avec l'appareil.
CONSOMMATEUR :
Conservez cette notice pour
consultation ultérieure.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 TABLE OF CONTENTS Packaging .........................................Page 2Introduction ......................................Page 2General Information ..........................Page 2Requirements for the Commonwealth of Massachusetts .Page 4New York City Approval .....................Page 4Cold C...
4 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Figure 2 - Dexen Electronic Gas Valve Pilot Stage Terminal Pressure-Tap (Inlet) Pilot Gas Outlet Supply Gas Inlet Pressure-Tap (Manifold) Burner Stage Terminal Ground (TP) PILOT OUT VENT LO TH TP TH TP HI IN IN Regulator Mounting Screw Test gaug...
5 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. • A hard wired carbon monoxide detector with an alarm and battery back-up must be installed on the floor level where the gas fireplace is installed. The carbon monoxide detector must comply with NFPA 720, be ANSI/UL 2034 listed and be ISA certif...