Lennox EDVPFNE-B - Manual

Lennox EDVPFNE-B

Lennox EDVPFNE-B – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
Page: / 44

Table of Contents:

  • Page 2 – TABLE OF CONTENTS; Please read and understand these; WARNING; GENERAL INFORMATION
  • Page 3 – Table 1
  • Page 4 – REQUIREMENTS FOR THE COMMON-; Tables 2 and 3; SIT Millivolt Gas Valve
  • Page 5 – LOCATION; peu de circulation et loin du mobilier et des tentures (Figure 3).; COLD CLIMATE INSULATION; Figure 3; TYPICAL LOCATION
  • Page 6 – VENT TERMINATION CLEARANCES; Termination Heights For Vents; Figure 6; Side Elevation View; Figure 4 - Multiple Terminations; Minimum
  • Page 7 – EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS
  • Page 8 – When the unit is installed with one side flush with a; Hearth Extension; the space between the appliance and the area; or surround materials must not be allowed to; Shelf Height Minimum Clearances
  • Page 9 – Top; Table 5; Unit Parts Identification; See; Figure 9
  • Page 10 – Figure 12 - Nailing Flanges; TYPICAL INSTALLATION SEQUENCE; refer
  • Page 11 – EDVST; EDVPF; FIREPLACE FRAMING SPECIFICATIONS
  • Page 12 – FLUE; FIREPLACE SPECIFICATIONS
  • Page 13 – FIREPLACE SPECIFICATIONS CONTINUED
  • Page 14 – Table 6; Step 3. PREPARING THE APPLIANCE; Figure 21 - Route Gas Line; Step 2. ROUTING GAS LINE
  • Page 15 – Approved Vent; on; the joints in the vent pipe.; restrictor in the top vent of the fireplace outlet.
  • Page 16 – Note: Convert inches into metric equivalent; Effective Vent Length; Model; Table 7; Figures 35 through 39; Secure FlexTM pipe may also be used. A Vertical; Figure 5; Tables on this page
  • Page 19 – VERTICAL VENT FIGURES/TABLES; which is ideal, though rise per foot run ratios; rate sections of concentric flexible; Ratio V to H ratio is 1:2
  • Page 20 – Ceiling; ) horizontal vent run is needed, then 4 feet minimum; Top Vent - THREE ELBOWS
  • Page 22 – tion Guard; Figure; Venting Connection and Exterior Wall Recessing of the
  • Page 23 – Table 8; HORIZONTAL VENT FIGURES/TABLES; Note: Two 45 degree elbows may be used in place of one 90 degree; When using; Under no circumstances, may separate sections of
  • Page 24 – ) horizontal run, up to a maximum horizontal
  • Page 26 – SECuRE FlEx; Secure Flex
  • Page 27 – Verify proper operation after servicing.; CAUTION
  • Page 28 – WIRING - OPTIONAL FORCED AIR; 50 forced air blower kits. Electrical power; Valve Access Side; Step 7. CONNECTING GAS LINE; Secure all joints tightly using appropriate; Remove the carton support from; Never use an open flame to; TEST ALL CONNECTIONS FOR GAS LEAKS
  • Page 29 – Note: using a soapy water solution is an; A. Light the appliance (refer to the lighting; TION; Note: lighting Instructions are also found on; Schematic Representation Only
  • Page 30 – Millivolt Appliance Checkout; ING EMBERS AND LOGS; NOTE: Turn off all electricity to the appliance; Electronic Appliance Checkout
  • Page 31 – Remove the front glass enclosure panel; DO NOT PLACE ANY VERMICULITE ON THE BURNER.; applications, do not use all that is in a new bag at one time. For best; REFERENCE; Glowing Embers
  • Page 32 – EDVPF, EDVST, EDVCL AND EDVCR LOG PLACEMENT; Log
  • Page 35 – achieved; Burner Flame Appearance
  • Page 36 – Step 12. HOOD INSTALLATION; Refer to Figure 66. All of these appliances; FINISHING REQUIREMENTS; Complete finished interior wall. To install the; See Page 5 for
  • Page 37 – Figure A
  • Page 38 – rigid; INSTALLATION ACCESSORIES; Listed Secure VentTM Components
  • Page 39 – INSTALLATION ACCESSORIES CONTINUED
  • Page 40 – this installation assumes responsibility for this conversion.; AVERTISSEMENT; assume les responsabilités liées à la conversion.
  • Page 41 – All Models; Note: If the ignitor is damaged, a replacement kit; Electronic Appliances
  • Page 42 – BURNER POSITIONING; PAN; Table 9
Loading the manual

OTL Report No. 116-F-04-5

US

Portland

MODELS

This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile

home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating

plate. This appliance is not convertible for use with other gases unless a certified kit is used.

INSTALLATION INSTRUC

TIONS

EDV Direct-Vent

Gas Fireplaces

P/N 850018M Rev. H 01/2011

This manual is one of a set of two supporting this product.

Refer to P/N 875022M for Care and Operation Instructions.

Ce manuel est disponible en francais, simplement

en faire la demande. Numéro de la pièce 850018CF.

AVERTISSEMENT : Assurez-vous de bien suivre les

instructions données dans cette notice pour réduire au

minimum le risque d’incindie ou d’explosion ou pour

éviter tout dommage matériel, toute blessure ou la mort.

- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs

ou liquides inflammables dans le voisinage de cet appareil

ou de tout autre appareil.

- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :

• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir des

téléphones se trouvant dans le bâtiment où vous trouvez.

• Appelez immédiatement votre fournisseur de gaz depuis

un voisin. Suivez les instructions du fournisseur.

• Si vous ne pouvez rejoindre le fournisseur de gaz,

appelez le service des incindies.

- L’installation et l’entretien doivent être assurés par un

installateur ou un service d’entretien qualifié ou par le

fournisseur de gaz.

WARNING: If the information in these instructions

is not followed exactly, a fire or explosion may

result, causing property damage, personal injury,

or death.

-

vapors and liquids in the vicinity of this or any other

appliance.

- WHAT TO DO IF YOU SMELL GAS:

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any

phone in your building.

• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s

instructions.

department.

- Installation and service must be performed by a

WARNING / AVERTISSEMENT / AVISO

• HOT GLASS WILL CAUSE

BURNS.

• DO NOT TOUCH GLASS

UNTIL COOLED.

• NEVER ALLOW CHILDREN

TO TOUCH GLASS.

• UNE SURFACE VITRÉE CHAUDE

PEUT CAUSER DES BRÛLURES.

• LAISSER REFROIDIR LA SURFACE

VITRÉE AVANT D'Y TOUCHER.

• NE PERMETTEZ JAMAIS À UN ENFANT

DE TOUCHER LA SURFACE VITRÉE.

• EL VIDRIO CALIENTE

CAUSARÁ QUEMADURAS.

• USTED DEBE NUNCA

TOCAR EL VIDRIO CALIENTE.

• LOS NIÑOS DEBEN NUNCA

TOCAR EL VIDRIO.

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.
INSTALLATEUR : Laissez cette notice avec l'appareil.

CONSOMMATEUR : Conservez cette notice pour

consultation ultérieure.

MILLIVOLT:

EDVSTNM-B

EDVSTPM-B

EDVPFNM-B

EDVPFPM-B

EDVCRNM-B

EDVCRPM-B

EDVCLNM-B

EDVCLPM-B

ELECTRONIC:

EDVSTNE-B

EDVPFNE-B

EDVCRNE-B

EDVCLNE-B

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TABLE OF CONTENTS; Please read and understand these; WARNING; GENERAL INFORMATION

2 TABLE OF CONTENTS Packaging .........................................Page 2Introduction ......................................Page 2General Information ..........................Page 2Requirements for the Commonwealth of Massachusetts .Page 4New York City Approval .....................Page 4Cold C...

Page 3 - Table 1

3 WARNING Improper installation, adjust- ment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier. WARNING Failure to comply with these installation i...

Page 4 - REQUIREMENTS FOR THE COMMON-; Tables 2 and 3; SIT Millivolt Gas Valve

4 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Test gauge connections are provided on the front of the millivolt and electronic gas control valve (identified IN for the inlet and OUT for the manifold side). The control valves have a 3/8" (10mm) NPT thread inlet and outlet side of the val...

Other Lennox Models