Lennox EBVI25 - Manual

Lennox EBVI25

Lennox EBVI25 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
Page: / 20

Table of Contents:

  • Page 3 – GENERAL INFORMATION; Installation, repair and annual service in-; TABLE OF CONTENTS; INTRODUCTION; Table 1; CONGRATULATIONS ON THE PURCHASE OF YOUR NEW GAS APPLIANCE MANU-; years of trouble-free warmth and pleasure.; Table 2 shows the main burner gas orifice; Table 2; Tables 3 and 4 show the gas pressure; Table 3
  • Page 4 – IMPORTANT; Keep your house well ventilated; Figure 1; Figure 2; MODEL EBVI5; GAS CONTROLS; must be isolated; equal to; must be disconnected; greater; CONTROL COMPARTMENT ACCESS; Figure 3
  • Page 5 – O P E R AT I O N A N D C A R E O F Y O U R; MAINTENANCE; Check Burner Flame Appearance; Glass Cleaning; Note: Clean glass after first two weeks of opera-; WARNING; Servicing Blower; Be; Figure 6; Access Panel
  • Page 6 – Refer to wiring diagrams on; CAUTION; Label all wires prior to discon-; Check; Figure 8; Remove Screws; opening of firebox (see Figure 9; Figure 7; Blower; Figure 9
  • Page 8 – Release latch on
  • Page 9 – Burner Adjustment Procedure; Adjustment Rod Up; LOGS, VERMICULITE AND EMBERS; Table 5; Installation Instructions
  • Page 12 – Figure 4 on Page 4; MILLIVOLT APPLIANCE CHECKOUT; Page 15 or 16 of this manual.; WIRING DIAGRAMS; Red
  • Page 13 – Millivolt Wiring Diagram
  • Page 15 – LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE; FOR YOUR SAFETY, READ BEFORE LIGHTING; WHAT TO DO IF YOU SMELL GAS; TO TURN OFF GAS TO APPLIANCE; Knob cannot be turned from “PILOT” to “OFF”; Millivolt Pilot
  • Page 16 – INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT; INSTRUCTIONS D'ALLUMAGE; VOICI CE QUE VOUS DEVEZ FAIRE SI VOUS DÉCELEZ UNE ODEUR; Il est impossible de tourner le bouton de “PILOT” à “OFF” à; POUR FERMER LE GAZ QUI ALIMENTE L’APPAREIL; SIT Vanne
  • Page 18 – REPLACEMENT PARTS DIAGRAMS
  • Page 19 – TROUBLESHOOTING THE MILLIVOLT GAS CONTROL SYSTEM; SYMPTOM
  • Page 20 – LENNOX HEARTH PRODUCTS; Natural Gas
Loading the manual

Report No. 116-F-15-5

CARE AND OPERATION INSTRUCTIONS

B-Vent Gas

Fireplace Heater Inserts

Do not store or use gasoline or other flammable

vapors or liquids in the vicinity of this or any other

appliance.

WHAT TO DO IF YOU SMELL GAS:
• Do not light any appliance.

• Do not touch any electrical switch; do not

Use any phone in your building.

• Immediately call your gas supplier from a

neighbor’s phone. Follow your gas supplier's

instructions.

• If your gas supplier cannot be reached, call

the fire department.

Installation and service must be performed by a quali-

fied installer, service agency or the gas supplier

.

POUR VOTRE SÉCURITÉ: Ne pas entreposer ni utiliser

d’essence ni d’autre vapeurs ou liquides inflammables dans

le voisinage de cet appareil ou de tout autre appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez une odeur

de gaz:
• Ne pas tenter d’allumer d’appareil.

• Ne touchez à aucun interrupteur. Ne pas vous servir

des téléphones se trouvant dans le batiment où vous

vous trouvez.

• Evacuez la piéce, le bâtiment ou la zone.

• Appelez immédiatement votre fournisseur de gaz depuis

un voisin. Suivez les instructions du fournisseur.

• Si vous ne pouvez rejoindre le fournisseur de gaz,

appelez le service dos incendies.
L’installation et service doit être exécuté par un qualifié instal-

leur, agence de service ou le fournisseur de gaz.

WARNING: If the information in this manual is not

followed exactly, a fire or explosion may result

causing property damage, personal injury or loss

of life.

AVERTISSEMENT: Assurez-vous de bien suivre les

instructions donné dans cette notice pour réduire au

minimum le risque d’incendie ou pour éviter tout dom-

mage matériel, toute blessure ou la mort.

Models: EBVI25 & EBVI30

US

P/N 775,155M Rev. E, 12/2007

WARNINGS

• Hot! Do not touch! The glass and surfaces of this appliance will be hot during operation and will

retain heat for a while after shutting off the appliance. Severe burns may result.

• Carefully supervise children in the same room as appliance.

• If small children are present in the home, it is recommended that this appliance be fitted with a

screen door or screen panel kit. See

Page 13

for ordering information.

• Suitable for installation into masonry or factory built fireplaces.

Lennox™ gas-burning appliances are designed for use as a supplemental heater. They are not intended for

continuous use as a primary heat source.

A French manual is available upon request. Order P/N 775,155CF.

Ce manuel d’installation est disponible en francais, simplement

en faire la demande. Numéro de la pièce 775,155CF.

Installer: Leave This Manual With The Appliance.

Consumer: Retain This Manual For Future Reference.

DR

AF

T

11

-05

-20

07

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - GENERAL INFORMATION; Installation, repair and annual service in-; TABLE OF CONTENTS; INTRODUCTION; Table 1; CONGRATULATIONS ON THE PURCHASE OF YOUR NEW GAS APPLIANCE MANU-; years of trouble-free warmth and pleasure.; Table 2 shows the main burner gas orifice; Table 2; Tables 3 and 4 show the gas pressure; Table 3

3 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Input of millivolt model is variable. The rates are shown in the following table: This millavolt appliance is designed to operate on either natural or propane gas. A millivolt gas control valve with piezo ignition system provides safe, efficient...

Page 4 - IMPORTANT; Keep your house well ventilated; Figure 1; Figure 2; MODEL EBVI5; GAS CONTROLS; must be isolated; equal to; must be disconnected; greater; CONTROL COMPARTMENT ACCESS; Figure 3

4 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Test gauge connections are provided on the front of the millivolt gas control valve (identi- fied IN for the inlet and OUT for the manifold side). See Figures 1 & 2. This appliance must not be connected to a chimney or flue serving a separat...

Page 5 - O P E R AT I O N A N D C A R E O F Y O U R; MAINTENANCE; Check Burner Flame Appearance; Glass Cleaning; Note: Clean glass after first two weeks of opera-; WARNING; Servicing Blower; Be; Figure 6; Access Panel

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 5 CAUTION Wear gloves and safety glasses for protection while doing required maintenance . IMPORTANT Always verify proper operation after servicing. WARNING Turn off gas and electrical power before servicing the appliance. O P E R AT I O N A N D C...

Other Lennox Models

All Lennox Other