2 DRYER SAFETY DRYER SAFETY .................................................................. 2 INSTALLATION REQUIREMENTS .......................................4 Tools and Parts ............................................................4 LOCATION REQUIREMENTS .......................................
Page 4 - TOOLS AND PARTS; Tools needed for all installations:; INSTALLATION REQUIREMENTS
4 TOOLS AND PARTS Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Tools needed for all installations: Level #2 Phillips screwdriver Wire stripper (direct wire installations) Flat-head screwdriver Adjustable wrenc...
Page 5 - LOCATION REQUIREMENTS
5 Parts supplied (all models): Tools needed for gas installations: 8" (203 mm) or 10" (254 mm) pipe wrench 8" (203 mm) or 10" (254 mm) adjustable wrench (for gas connections) Pipe-joint compound resistant to LP gas Leveling legs (4) (Length and appearance of legs may vary according t...
Page 6 - DRYER DIMENSIONS; Mobile home installations require:; For gas dryers mobile home installations:; Spacing for recessed area or closet installation
6 DRYER DIMENSIONS Front View 50 3 / 4 " (1289 mm) 42" (1067 mm) 28 1 / 4 " (717 mm) 28 1 / 4 " (717 mm) NOTE: Minimum height of leveling legs should be 1/2" (13 mm), or to match the height of the accompanying washer. Side View 29" (737 mm) 40 7 / 8 " (1038 mm) 1 / 2 "...
Page 7 - ELECTRICAL REQUIREMENTS
7 ELECTRICAL REQUIREMENTS – U.S.A. ONLY (SPÉCIFICATIONS ÉLECTRIQUES – ÉTATS-UNIS SEULEMENT) ELECTRICAL REQUIREMENTS It is your responsibility: ■ To contact a qualified electrical installer. ■ To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ...
Page 8 - GROUNDING INSTRUCTIONS; GAS DRYER POWER HOOKUP –; GAS SUPPLY REQUIREMENTS
8 4-wire receptacle (14-30R) ELECTRIC DRYER POWER HOOKUP – CANADA ONLY ELECTRICAL REQUIREMENTS It is your responsibility: ■ To contact a qualified electrical installer. ■ To be sure that the electrical connection is adequate and in conformance with Canadian Electrical Code, C22.1-latest edition and ...
Page 9 - GAS SUPPLY CONNECTION REQUIREMENTS; BURNER INPUT REQUIREMENTS; INSTALL LEVELING LEGS; Prepare dryer for leveling legs
9 3/8" NPT dryer pipe NOTE: For a garage installation, the gas pipe height must be an additional 18" (460 mm) from the fl oor. GAS SUPPLY CONNECTION REQUIREMENTS ■ Use an elbow and a 3/8" fl are x 3/8" NPT adapter fi tting between the fl exible gas connector and the dryer gas pipe, a...
Page 10 - Screw in leveling legs; LE RACCORDEMENT ÉLECTRIQUE – ÉTATS-UNIS SEULEMENT); Electrical Connection Options; Choose electrical connection type; For mobile home use
10 2. Screw in leveling legs Using a wrench and tape measure, screw leveling legs into leg holes until bottom of foot is approximately 1/2" (13 mm) from bottom of dryer (so that the dryer height matches that of the accompanying washer).Now stand the dryer on its feet. Slide the dryer until it is...
Page 11 - Attach power supply cord strain relief; Power Supply Cord Strain Relief; POWER SUPPLY CORD CONNECTION; Attach power supply cord to strain relief; -wire Power Supply Cord Connection; If your outlet looks like this:
11 D C B A 1. Attach power supply cord strain relief Remove the screws from a 3/4" (19 mm) UL listed strain relief (UL marking on strain relief). Put the tabs of the two clamp sections (C) into the hole below the terminal block opening (B) so that one tab is pointing up (A) and the other is poin...
Page 12 - -wire Power Supply Cord Connection
12 Remove center terminal block screw (B). Remove neutral ground wire (E) from external ground conductor screw (A). Reinstall ground conductor screw (A). B A E 1. Prepare to connect neutral ground wire and neutral wire B C E 2. Connect neutral ground wire and neutral wire Connect neutral ground wire...
Page 13 - Connect remaining wires; Connect neutral wire; DIRECT WIRE CONNECTION; Attach direct wire strain relief; Direct Wire Strain Relief
13 3. Connect remaining wires Connect remaining wires to outer terminal block screws. Tighten screws. Finally, reinstall terminal block cover. Secure cover with hold down screw. Now, go to “Venting Requirements.” 2. Connect neutral wire Connect neutral wire (white or center) (C) of power supply cord...
Page 14 - If your wiring looks like this:; -wire Direct Wire Connection
14 Put direct wire cable through the strain relief. The strain relief should have a tight fi t with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against the direct wire cable. 2. Attach direct wire cable to strain relief 3-wire direct connection:Go to “3-wire Direct...
Page 15 - -wire Direct Wire Connection; Use where local codes permit connecting cabinet-ground; Optional 3-wire Connection with External; You must verify with a qualified electrician that this
15 Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right). Squeeze hooked ends together and tighten screws. Finally, reinstall terminal block cover. Secure cover with hold-down screw. Now, go to “Venting Requirements.” 5. Connect remaining wires...
Page 16 - Plan pipe fi tting connection; MAKE GAS CONNECTION –
16 B C E 2. Connect neutral ground wire and neutral wire Connect neutral ground wire (E) and neutral wire (white or center wire) (C) of power supply cord or cable under center terminal block screw (B). Tighten screw. 3. Connect remaining wires Place hooked ends of remaining wires under outer termina...
Page 17 - Venting Requirements; VENTING
17 Venting Requirements WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS. IMPORTANT: Observe all governing codes and ordinances. Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Only rigid ...
Page 18 - Plan Vent System; Recommended exhaust installations; Special provisions for mobile homes:; Vent System Chart
18 Plan Vent System Recommended exhaust installations Typical installations vent the dryer from the rear of the dryer. Other installations are possible. B B C D E E F G H A A. Dryer B. Elbow C. Wall D. Exhaust hood E. Clamps F. Rigid metal or flexible metal vent G. Vent length necessary to connect e...
Page 19 - CONNECT INLET HOSES; INSTALL VENT SYSTEM; Turn cold water off remove and replace
19 CONNECT INLET HOSES For non-steam models, skip to “Connect Vent.” The dryer must be connected to the cold water faucet using the new inlet hoses. Do not use old hoses. 2. Connect vent to exhaust hood Vent must fi t over the exhaust hood. Secure vent to exhaust hood with 4" (102 mm) clamp. Run...
Page 20 - CONNECT VENT
20 5. Attach long hose to dryer fi ll valve and tighten coupling 7. Check for leaks Check for leaks around “Y” connector, faucets, and hoses. 6. Turn on cold water faucet Check that the water faucet is turned on. CONNECT VENT 1. Connect vent to exhaust outlet Using a 4" (102 mm) clamp, connect v...
Page 21 - LEVEL DRYER; Level dryer; COMPLETE INSTALLATION
21 LEVEL DRYER Not Level LEVEL Not Level Check levelness of dryer from side to side. Repeat from front to back. NOTE: The dryer must be level for the moisture sensing system to operate correctly. 1. Level dryer 2. Adjust leveling legs If dryer is not level, prop up using a wood block. Use wrench to ...
Page 22 - Remove screws from hinges
22 REVERSE DOOR SWING (OPTIONAL) NOTE: Magnetized screwdriver is helpful. Place towel on top of dryer to avoid damaging the surface. 1. Place towel on dryer 2. Remove bottom screws Open dryer door. Remove bottom screws from dryer cabinet side of hinges. Loosen (do not remove) top screws from dryer c...
Page 24 - TROUBLESHOOTING
24 12. Insert screws in hinge holes on dryer cabinet NOTE: Two people may be needed to reinstall door. Insert screws into the bottom holes on left side of dryer cabinet. Tighten screws halfway. Position door so large end of door hinge slot is over screws. Slide door up so screws are in bottom of slo...