Page 2 - Introduction
2 AC-Series Operator’s Manual-E/F Introduction THANK YOU for purchasing a John Deere product. READ THIS MANUAL carefully to learn how to operate and service your machine correctly. Failure to do so could result in personal injury or equipment damage. This manual and safety signs on your machine may ...
Page 3 - Contents
AC-Series Operator’s Manual-E/F 3 Contents Page Safety .................................................................................. 5 Safety Signs ..................................................................... 10 Controls ....................................................................
Page 5 - Safety; RECOGNIZE SAFETY INFORMATION
AC-Series Operator’s Manual-E/F 5 Safety RECOGNIZE SAFETY INFORMATION This is the safety alert symbol. When you see this symbol on your machine or in this manual, be alert to the potential for personal injury. Follow recommended precautions and safe operating practices. UNDERSTAND SIGNAL WORDS A sig...
Page 7 - MSDS
AC-Series Operator’s Manual-E/F 7 CLEANING DETERGENT PRECAUTIONS Know the detergent being used. Be prepared to tell a physician exactly what you are using in the event of an emergency. Read all detergent labels and follow all instructions exactly regarding preparation, use, safety, transportation, a...
Page 10 - WARNING/AVERTISSEMENT; WARNING/AVERTISSEMENT
10 AC-Series Operator’s Manual-E/F SAFETY SIGNS FOR AC-2000GH, AC-2400GH, AC-2600GH, AC-2700GH, AC-3300GH, AC-2400GS, AC-2700GS AND AC-3000GS SAFETY SIGNS FOR AC-2500GH Location: Beltguard-Inside Location: Beltguard-Left Side Location: Fuel Tank-Top Location: Beltguard-Top Location: Beltguard-Backsi...
Page 12 - Controls
12 AC-Series Operator’s Manual-E/F D B A C D B A C Controls AC-2000GH PIC161-101599R1 AC-2500GH AC-2700GH AC-2400GH PIC164-101599R1 AC-2400GS AC-2700GS PIC62-101599R1 PIC161R-121902R0 PIC62R-121902R0 D B A C D B A C B A D B A C AC-2600GH PIC60-101599R0 D B A C PIC60-101599R0
Page 13 - HONDA ENGINE; SUBARU ENGINE
AC-Series Operator’s Manual-E/F 13 K J H I A-- Water Supply Inlet B-- High Pressure Outlet C-- Detergent Hose D-- Pressure Adjusting Knob E-- High Pressure Hose F-- Gun G-- Nozzle H-- Engine On/Off Switch I -- Throttle J-- Choke K-- Fuel Shut-off Valve AC-3300GH HONDA ENGINE PIC63-101599R0 PIC66-101...
Page 14 - CHECK ENGINE OIL; Preparing the Washer; GASOLINE ENGINE OIL
14 AC-Series Operator’s Manual-E/F CHECK ENGINE OIL NOTE: All washers are shipped with engine oil. Check proper level. (AC-2400GH illustrated.) 1. Place unit on level surface.2. Remove oil filler cap/dipstick (A) and wipe it clean.3. Insert filler cap/dipstick into oil filler neck, but DO NOT screw ...
Page 15 - FILLING FUEL TANK
AC-Series Operator’s Manual-E/F 15 FILLING FUEL TANK CAUTION: Risk of fire. Handle fuel carefully. -Do not add fuel when product is operating. Stop engine and allow engine to cool for two minutes before refueling. Hot surfaces can cause burns and ignite spilled fuel. Do not touch muffler. -Fill fuel...
Page 16 - INLET WATER SUPPLY REQUIREMENTS
16 AC-Series Operator’s Manual-E/F INLET WATER SUPPLY REQUIREMENTS 1. Inlet water supply must be a minimum of 20 PSI (1.4 bar). Attempting to operate the washer with less than adequate water supply will cause rapid wear of packings, valves and bearings that will dramatically shorten pump life. Sympt...
Page 17 - CHECK PUMP OIL
AC-Series Operator’s Manual-E/F 17 PIC72-101 199R0 CHECK PUMP OIL 1. Put unit on level surface.2. Check oil as follows: •ALL MODELS: View level through clear window (A). Oil should fill sight glass.•Additional method for AC-2500GH, AC-2700GH, AC-3300GH, AC-2700GS, AC-3000GS and AC-3500GH only: - Rem...
Page 18 - CONNECT DISCHARGE HOSE TO GUN
18 AC-Series Operator’s Manual-E/F CONNECT DISCHARGE HOSE TO GUN CAUTION: Check pressure rating printed on the hose. Use proper hoses.Use ONLY hose #851-0338, working pressure of 4000 PSI with the AC-3300GH and AC-3500GH pressure washer.Hose #851-0007, with working pressure of 3000 PSI can safely be...
Page 19 - CONNECT HOSES AND PRIME PUMP
AC-Series Operator’s Manual-E/F 19 Preparing the Washer CONNECT HOSES AND PRIME PUMP IMPORTANT: Be sure that inlet water screen (A) is clean and in place before connecting water supply hose to A C - 2 0 0 0 G H , A C - 2 4 0 0 G H , A C - 2 6 0 0 G H , A C - 2 7 0 0 G H , A C - 3 3 0 0 G H , A C - 2...
Page 20 - INSTALLING NOZZLE; FINAL CHECKLIST
20 AC-Series Operator’s Manual-E/F INSTALLING NOZZLE CAUTION: To avoid injury from escaping fluids under pressure, relieve the pressure in the system by stopping the washer and depressing gun trigger. Lock trigger before changing or adjusting nozzle.Be sure nozzle is tightly attached before operatin...
Page 21 - Operating the Washer; STARTING AND OPERATING ENGINE; STOPPING THE ENGINE
AC-Series Operator’s Manual-E/F 21 Operating the Washer STARTING AND OPERATING ENGINE CAUTION: Do not run engine in an enclosed area. Exhaust gas contains carbon monoxide, an odorless and poisonous gas that can cause sickness or death. IMPORTANT: To prevent possible pump damage, do not allow washer ...
Page 22 - LOCKING GUN TRIGGER; ADJUSTING WATER PRESSURE
22 AC-Series Operator’s Manual-E/F LOCKING GUN TRIGGER CAUTION: Gun trigger should be locked when not in use or whenever adjustments are being made to gun or nozzle. This will help prevent accidental discharge of high pressure fluid. 1. Pivot lock (A) down to prevent trigger engagement.2. Pivot lock...
Page 24 - DETERGENT INJECTOR NOZZLE-BLACK
24 AC-Series Operator’s Manual-E/F Operating the Washer 15° NOZZLE-YELLOW This nozzle provides a chiseling effect suitable for surface preparation. The spray should be directed at a 45° angle to the surface. Recommended uses are: -Removing peeling paint.-Removing mildew stains. PIC86-102299R0 25° NO...
Page 25 - CLEANING HORIZONTAL SURFACES
AC-Series Operator’s Manual-E/F 25 Operating the Washer CLEANING HORIZONTAL SURFACES Move nozzle wand from side to side. Direct spray at an angle to force debris ahead and away from the cleared area. Depending on the material to be removed and nozzle pressure, hold nozzle end 8 to 10 inches (20 to 2...
Page 26 - REMOVING PAINT
26 AC-Series Operator’s Manual-E/F Operating the Washer REMOVING PAINT IMPORTANT: Remember that high pressure spray can gouge soft woods and other materials, as well as loosen grout. 1. Direct spray at a 45° angle about 4 to 12 inches (10 to 30 cm) from surface. 2. Spray in a back and forth motion, ...
Page 27 - DETERGENT USAGE GUIDE
AC-Series Operator’s Manual-E/F 27 Operating the Washer DETERGENT USAGE GUIDE CAUTION: Use detergents carefully. Read labels thoroughly and follow all instructions for preparation, use, safety, transportation and disposal. Be prepared to tell a physician exactly what detergents you are using in the ...
Page 28 - CLEANING WITH DETERGENTS
28 AC-Series Operator’s Manual-E/F CLEANING WITH DETERGENTS (ACCESSORY ON AC-2500GH & AC-3500GH ONLY) CAUTION: Wear goggles, respirator, and protective clothing to help prevent injury from detergents and spray. IMPORTANT: DO NOT direct pressure washer spray at the washer. 1. Mix detergent as ins...
Page 30 - SHUTDOWN
30 AC-Series Operator’s Manual-E/F SHUTDOWN IMPORTANT: Shutdown procedures should be followed at the end of each cleaning operation. 1. If a detergent was used, place detergent inlet strainer in CLEAN water and operate trigger to spray water for a period of three minutes. This will flush the system ...
Page 31 - Troubleshooting
AC-Series Operator’s Manual-E/F 31 Troubleshooting Symptom Problem Solution No discharge at nozzle when Low pressure or no water supply. Ensure hose is 5/8 in. inside diameter trigger mechanism is squeezed. and incoming water supply is turned on. Obstruction in nozzle. Clean or replace nozzle. Low o...
Page 33 - Service Chart
AC-Series Operator’s Manual-E/F 33 Service Chart First 20 hours Every 25 hours Every 100 hours Every 250 hours Every 300 hours Clean Air Filter ......................................................................................... X (2) Change Air Filter .............................................
Page 34 - Service; CLEAN INLET WATER SCREEN-ALL MODELS; CLEAN DETERGENT HOSE STRAINER
34 AC-Series Operator’s Manual-E/F PIC21-101599R0 PIC77-102299R1 CLEAN INLET WATER SCREEN-AC-2500GH AND AC-3500GH IMPORTANT: Do not operate washer with inlet water screen removed. Foreign material may enter and damage pump or valves. Inspect the inlet screen (A) periodically for build-up of scale, d...
Page 35 - CHECKING WATER PUMP OIL
AC-Series Operator’s Manual-E/F 35 CHECKING WATER PUMP OIL IMPORTANT: If oil is white or foaming, water is in the oil reservoir. Change oil. NOTE: Wa t e r i n o i l o c c u r s a s a r e s u l t o f s p r a y o r condensation. Milky oil is not indicative of a pump malfunction. 1. Stop engine.2. Put...
Page 36 - CHANGING WATER PUMP OIL
36 AC-Series Operator’s Manual-E/F Service CHANGING WATER PUMP OIL IMPORTANT: Change pump break-in oil after first 20 hours of operation and at 250 hour intervals thereafter. 1. Put unit on level surface.2. With water flowing through pump, run unit for a few minutes to warm oil. 3. Stop engine and c...
Page 37 - CHANGING ENGINE OIL
AC-Series Operator’s Manual-E/F 37 Service PIC96-102299R0 PIC67-102299R1 GASOLINE ENGINE OIL Use oil viscosity based on the expected air temperature range during the period between oil changes. John Deere TURF-GARD TM is preferred. Also recommended is John Deere PLUS-4 ® . Other oils may be used if ...
Page 38 - CLEAN AIR FILTER ELEMENT
38 AC-Series Operator’s Manual-E/F CLEAN AIR FILTER ELEMENT AC-2000GH ONLY: 1. Push lower part of tabs (A) inward and through tab holders to remove cleaner cover. 2. Remove paper element (D).3. Remove excess dirt from paper element (D) by tapping lightly on hard surface, or by blowing compressed air...
Page 40 - ADJUST BELT TENSION -
40 AC-Series Operator’s Manual-E/F ADJUST BELT TENSION - AC-2500GH & AC-3500GH ONLY NOTE: Check/adjust belt tension after every 25 hours of use. 1. Twist locking screw (A) 1/4 turn and lift off belt guard.2. Inspect belts for wear, cracks or fraying. Replace belts if damaged. 3. Loosen the four ...
Page 41 - STORING THE WASHER; Storage; REMOVING WASHER FROM EXTENDED
AC-Series Operator’s Manual-E/F 41 STORING THE WASHER IMPORTANT: Protect washer from freezing temperatures. If unit will experience freezing conditions, pump must be filled with antifreeze to prevent cracking of pump manifold and relief valve due to water expansion. Draining alone will not remove al...
Page 42 - Specifications; SPECIFICATIONS
42 AC-Series Operator’s Manual-E/F Specifications SPECIFICATIONS ITEM Model AC-2000GH Model AC-2400GH Model AC-2500GH Model AC-2600GH Model AC-2700GH Operating Pressure 1900-2050 2300-2400 PSI 2375-2500 PSI 2450-2575 PSI 2580-2720 PSI Measured at Pump Manifold ......... (131-141 Bar) (159-165 Bar) (...
Page 43 - RECORD SERIAL NUMBER
AC-Series Operator’s Manual-E/F 43 ITEM Model AC-3300GH Model AC-2400GS Model AC-2700GS Model AC-3000GS Model AC-3500GH Operating Pressure 3250-3350 PSI 2300-2400 PSI 2580-2720 PSI 3250-3350 PSI 3400-3500 PSI Measured at Pump Manifold ......... (224-231 Bar) (159-165 Bar) (178-188 Bar) (224-231 Bar)...
Page 44 - HIGH PRESSURE HOSE EXTENSION:; Accessories
44 AC-Series Operator’s Manual-E/F PIC109-102299R0 PRESSURE TEST GAUGE: 852-0044 FOR AC-2700GH, AC-3300GH, AC-2700GS, AC-3000GS & AC-3500GH This glyerine filled gauge indicates working and relief pressures. HIGH PRESSURE HOSE EXTENSION: FOR AC-2000GH, AC-2400GH, AC-2400GS, AC-2500GH, AC-2600GH, ...
Page 49 - Notes
Page 53 - Table des matières
AC-Series Operator’s Manual-E/F 53 Table des matières Page Sécurité ............................................................................ 55 Étiquettes de sécurité ..................................................... 60 Commandes .................................................................
Page 55 - Sécurité; DANGER
AC-Series Operator’s Manual-E/F 55 RECONNAÎTRE LES SYMBOLES DE MISE EN GARDE Voici le symbole de mise en garde. Lorsqu’il apparaît sur la machine ou dans la présente publication, c’est pour prévenir d’un risque potentiel de blessure. Respecter tous les conseil de sécurité ainsi que les consignes gén...
Page 57 - PRÉCAUTIONS À PRENDRE AVEC LES
AC-Series Operator’s Manual-E/F 57 MSDS PRÉCAUTIONS À PRENDRE AVEC LES DÉTERGENTS DE NETTOYAGE Savoir quel détergent on utilise. En cas d’urgence, être capable d’indiquer exactement au médecin le produit utilisé. Lire toutes les indications relatives au produit et suivre exactement toutes les instru...
Page 62 - Commandes
62 AC-Series Operator’s Manual-E/F Commandes D B A C D B A C AC-2000GH PIC161-101599R1 AC-2500GH AC-2700GH AC-2400GH PIC164-101599R1 AC-2400GS AC-2700GS PIC62-101599R1 PIC161R-121902R0 PIC62R-121902R0 D B A C D B A C B A D B A C AC-2600GH PIC60-101599R0 D B A C PIC60-101599R0
Page 63 - PRESSION; HONDA DE MOTEUR
AC-Series Operator’s Manual-E/F 63 PISTOLET, GICLEUR, FLEXIBLE HAUTE PRESSION A-- Admission d’eau B-- Sortie de haute pression C-- Flexible à haute pression D-- Pistolet E-- Gicleur F-- Flexible de produits chimiques G-- Bouton de réglage de pression H-- Interrupteur marche-arrêt du moteur I -- Mane...
Page 64 - Préparation de l’appareil de lavage; VÉRIFICATION DE L’HUILE À MOTEUR; HUILE À MOTEUR À ESSENCE
64 AC-Series Operator’s Manual-E/F PIC67-102899R1 -40°F -22°F -4°F 14°F 32°F 50°F 68°F 86°F 104°F 122°F 50°C 40°C 30°C 20°C 10°C 0°C -10°C -20°C -30°C -40°C SAE 10W -40 SAE 10W -30 SAE 5W -30 PIC1 10-102899R0 Préparation de l’appareil de lavage VÉRIFICATION DE L’HUILE À MOTEUR REMARQUE: AC-2400GH il...
Page 66 - EXIGENCES POUR L’ALIMENTATION EN EAU
66 AC-Series Operator’s Manual-E/F PIC4-092299R0 EXIGENCES POUR L’ALIMENTATION EN EAU 1. Une alimentation en eau avec une pression de 20 lb/po 2 (1,4 bar) ou plus est nécessaire. Faire fonctionner l’appareil de lavage avec un débit d’alimentation inadéquat provoquera l’usure rapide des garnitures d’...
Page 67 - VÉRIFIER LE NIVEAU D’HUILE DE LA POMPE
AC-Series Operator’s Manual-E/F 67 PIC72-101 199R0 VÉRIFIER LE NIVEAU D’HUILE DE LA POMPE 1. P l a c e r l ’ a p p a r e i l d e l a v a g e s u r u n e s u r f a c e horizontale. 2. Vérifier le niveau d’huile de la façon suivante: POUR TOUS LES MODÈLES: Vérifier le niveau d’huile à travers la vitre...
Page 68 - FIXER LE FLEXIBLE DE DÉCHARGE AU
68 AC-Series Operator’s Manual-E/F Préparation de l’appareil de lavage FIXER LE FLEXIBLE DE DÉCHARGE AU PISTOLET ATTENTION: Vérifier la pression nominale indiquée sur le flexible. Utiliser les flexibles appropriés. Utiliser seulement un flexible 851-0338 ayant une pression d’utilisation de 4000 lb/p...
Page 70 - INSTALLATION DU GICLEUR; VÉRIFICATIONS AVANT LE DÉMARRAGE
70 AC-Series Operator’s Manual-E/F PIC81•102299R0 INSTALLATION DU GICLEUR ATTENTION: Afin d’éviter des blessures provenant du jet à haute pression, éliminer la pression dans le système en arrêtant l’appareil de lavage et en appuyant sur la gâchette. Verrouiller la gâchette avant de changer ou d’ajus...
Page 71 - DÉMARRAGE DU MOTEUR; Utilisation
AC-Series Operator’s Manual-E/F 71 DÉMARRAGE DU MOTEUR ATTENTION: NE PAS faire fonctionner le moteur à l’intérieur. Les fumées d’échappement contiennent de l’oxyde de carbone, un gaz toxique et sans odeur. IMPORTANT: Afin d’éviter d’endommager la pompe, ne pas laisser l’appareil de lavage fonctionne...
Page 72 - ARRÊT DU MOTEUR
72 AC-Series Operator’s Manual-E/F ARRÊT DU MOTEUR AC-2000GH ET AC-2600GH SEULEMENT IMPORTANT: Pour arrêter le moteur en cas d’urgence, tourner la manette d’accélération vers le bas (C) à la position «OFF» (arrêt). 1. Déplacer la manette d’accélération (C) à la position «OFF» (arrêt). 2. Appuyer sur...
Page 73 - RÉGLAGE DE LA PRESSION D’EAU; VERROUILLAGE DE LA GÂCHETTE
AC-Series Operator’s Manual-E/F 73 Utilisation RÉGLAGE DE LA PRESSION D’EAU Tourner le bouton de réglage de la pression (A) dans les sens des aiguilles d’une montre pour augmenter la pression et en sens inverse des aiguilles d’une montre pour diminuer la pression. REMARQUE: La pression d’eau est pré...
Page 78 - GUIDE D’UTILISATION DES DÉTERGENTS
78 AC-Series Operator’s Manual-E/F GUIDE D’UTILISATION DES DÉTERGENTS ATTENTION: Utiliser les détergents et produits chimiques avec précaution. Lire attentivement les étiquettes et suivre toutes les instructions pour la préparation, l’utilisation, la sécurité, le transport et l’élimination. En cas d...
Page 79 - NETTOYAGE AVEC SOLUTION DE NETTOYAGE
AC-Series Operator’s Manual-E/F 79 NETTOYAGE AVEC SOLUTION DE NETTOYAGE (ACCESSOIRE AVEC AC-2500GH ET AC-3500GH) ATTENTION: Porter des lunettes de protection, un respirateur et des vêtements de protection pour éviter toute blessure deu au jet ou aux produits chimiques. IMPORTANT: Ne pa diriger le je...
Page 81 - ARRÊT DE L’APPAREIL DE LAVAGE ET DU
AC-Series Operator’s Manual-E/F 81 Utilisation ARRÊT DE L’APPAREIL DE LAVAGE ET DU MOTEUR IMPORTANT: Les procédures d’arrêt devraient être suivies à la fin de chaque opération de nettoyage. 1. Si un détergent a été utilisé, mettre la crépine d’admission de détergent dans de l’eau PROPRE et appuyer s...
Page 82 - Dépannage
82 AC-Series Operator’s Manual-E/F Symptôme Probléme Solution Aucune décharge au gicleur Faible pression ou aucune alimentation S’assurer que le flexible a un diamètre lorsque la gâchette est appuyée. en eau. intérieur de 5/8 po et que l’alimentation en eau est ouverte. Le gicleur est colmaté. Netto...
Page 84 - Entretien du Calendrier
84 AC-Series Operator’s Manual-E/F CALENDRIER Après 20 heures À toutes les À toutes les À toutes les À toutes les 25 heures 100 heures 250 heures 300 heures Nettoyer le filtre à air ................................................................................ X (2) Changer le filtre à air...........
Page 85 - NETTOYAGE DE LA CRÉPINE D’ENTRÉE; Entretien
AC-Series Operator’s Manual-E/F 85 PIC21-101599R0 NETTOYAGE DE LA CRÉPINE D’ENTRÉE D’EAU- TOUS LES MODÈLES À L’EXCLUSION D’AC-2500GH ET D’AC-3500GH IMPORTANT: Ne pas faire fonctionner l’appareil de lavage lorsque les crépines d’entrée d’eau sont enlevées. Sans les crépines, des corps étrangers peuve...
Page 87 - VIDANGE DE L’HUILE DE LA POMPE À EAU
AC-Series Operator’s Manual-E/F 87 VIDANGE DE L’HUILE DE LA POMPE À EAU IMPORTANT: Vidanger l’huile de rodage de la pompe après les 20 premières heures de fonctionnement et après cela, à intervalles de 250 heures. 1. Placer l’appareil de lavage sur une surface horizontale.2. Avec l’eau circulant à t...
Page 88 - VÉRIFICATION DE L’HUILE Á MOTEUR; VIDANGE DE L’HUILE À MOTEUR
88 AC-Series Operator’s Manual-E/F PIC96-102299R0 DWG13-102299R0 -40°F -22°F -4°F 14°F 32°F 50°F 68°F 86°F 104°F 122°F 50°C 40°C 30°C 20°C 10°C 0°C -10°C -20°C -30°C -40°C SAE 10W -40 SAE 10W -30 SAE 5W -30 PIC1 10-102299R0 Entretien VÉRIFICATION DE L’HUILE Á MOTEUR REMARQUE: AC-2400GH illustré 1. A...
Page 89 - ENTRETIEN DU FILTRE À AIR
AC-Series Operator’s Manual-E/F 89 Entretien ENTRETIEN DU FILTRE À AIR AC-2000GH:1. Ouvrir le couverture.2. Retirer l’élément en papier.3. Enlever l’excès de poussière sur l’élément en papier (D) en donnant de petits coups sur une surface dure ou en envoyant de l’air comprimé à l’intérieeur de l’élé...
Page 91 - RÉGLAGE DE TENSION DE LA COURROIE-
AC-Series Operator’s Manual-E/F 91 PIC105-102299R0 PIC104-101599R0 PIC106-102299R0 Entretien RÉGLAGE DE TENSION DE LA COURROIE- AC-2500G ET AC-3500GH SEULEMENT REMARQUE: Vérifier/régler la tension de la courroie aprés chaque 25 heures d’utilisation. 1. Tourner la vis de blocage (A) d’un quart de tou...
Page 92 - REMISAGE DE L’APPAREIL DE LAVAGE; Remisage; SORTIE DE L’APPAREIL DE LAVAGE DU
92 AC-Series Operator’s Manual-E/F ATTENTION: Les vapeurs d’essence peuvent s’accumuler et exploser si elles sont exposées à une flamme ou à des étincelles. Si vous entreposez l’appareil de lavage avec du carburant dans le réservoir, assurez-vous qu’il n’y a aucune flammes, veilleuse ou mécanisme ac...
Page 93 - Caractéristiques; CARACTÉRISTIQUES
AC-Series Operator’s Manual-E/F 93 Caractéristiques CARACTÉRISTIQUES Article Modèle AC-2000GH Modèle AC-2400GH Modèle AC-2500GH Modèle AC-2600GH Modèle AC-2700GH Pression de travail 1900-2050 PSI 2350-2400 lb/po 2 2350-2400 lb/po 2 2450-2575 lb/po 2 2580-2720 lb/po 2 Mesurée au collecteur de pompe ....
Page 94 - NOTER LE NUMÉRO DE SÉRIE
94 AC-Series Operator’s Manual-E/F Article Modèle AC-3300GH Modèle AC-2400GS Modèle AC-2700GS Modèle AC-3000GS Modèle AC-3500GH Pression de travail 3250-3350 lb/po 2 2350-2400 lb/po 2 2580-2720 lb/po 2 3250-3350 lb/po 2 3400-3500 lb/po 2 Mesurée au collecteur de pompe .......... (224-231 bar) (162-1...
Page 95 - Accessoires; FLEXIBLES HAUTE PRESSION :
AC-Series Operator’s Manual-E/F 95 PIC109-102299R0 PIC34-090199R0 851-0007 & 851-0338 Accessoires FLEXIBLES HAUTE PRESSION : - AC-2000GH, AC-2400GH, AC-2400GS, AC- 2500GH, AC-2600GH, AC-2700GH, AC-2700GS ET AC-3000GS: 851-0007 - AC-3300GH ET AC-3500GH: 851-0338 IMPORTANT: N E PA S u t i l i s e ...
Page 96 - PRÉPARATION DE LA SURFACE:
96 AC-Series Operator’s Manual-E/F PIC37-090199R0 PIC35-090199R0 PIC36-090199R0 PIC55-101599R0 DOSEUR DE DETERGENTS: AW-8000-J000 DE AC-2500GH ET AC-3500GH Le dispositif d’injection de produits chimiques est installé entre la pompe et le flexible haute pression et peut être réglé pour obtenir un dos...
Page 98 - CONDITIONNEUR ET STABILISATEUR
98 AC-Series Operator’s Manual-E/F Hac1-092299R0 PIC151-1 13099R0 PIC150-1 13099R0 Accessoires CONDITIONNEUR ET STABILISATEUR D’ESSENCE: TY15977 Utiliser le conditionneur et stabilisateur d’essence John Deere pour aider à prévenir la formation de gomme et de vernis dans le système de carburant. HUIL...
Page 99 - CONDITIONS DE LA GARANTIE
AC-Series Operator’s Manual-E/F 99 CONDITIONS DE LA GARANTIE Le fabricant garantit toutes les pièces (à l’exception de celles listées ci-dessous) de votre nettoyeur pression pendant la durée suivante: Cinq (5) année à compter de la date d’achat: Pompe haute pression Deux (2) année à compter de la da...