Jackson PRO-9776 - Manual

Jackson PRO-9776

Jackson PRO-9776 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
Page: / 24

Table of Contents:

  • Page 4 – This Remote Start/Alarm System is designed to be used with; Automatic Transmission Vehicles Only!; . If the diesel engine has a; MUST HAVE a Tach Signal; INSTALLATION OF THE MAJOR COMPONENTS:; HOOD AND TRUNK PIN SWITCHES:
  • Page 5 – only! Although this combination; IT MUST NOT; be installed
  • Page 6 – YELLOW START WIRE DETAIL; Ignition 1 Output
  • Page 7 – Do not remove the fuse holders from this wire harness. Fuses must be
  • Page 8 – WIRING CONNECTIONS: Multi Pin Accessory Input/Output Harness; Parking Light Flasher Feed; Parking Light Wiring Detail; SIREN
  • Page 10 – General Motors VATS By-Pass Diagram; Ignition 3 Output
  • Page 11 – Entry Illumination Ground Output; Entry Illumination Detail; Negative Inhibit Input; Grey w/ Black Trace Negative Inhibit Safety Shut Down Detail
  • Page 12 – Brake Switch Positive Shutdown Detail
  • Page 13 – Chassis Ground Source; Chassis Ground Connection Detail; Tachometer Input Signal; Tachometer Input Wiring Detail; Diesel Wait To Start Input
  • Page 14 – Negative Door Switch Wiring Detail; Delayed 300mA Pulsed Channel 3 Output; Channel 3 Relay Wiring Detail; 00mA Latched Channel 4 Output
  • Page 16 – Wire Ground Switched Door Lock/Unlock Wiring Detail
  • Page 17 – Wire Positive Switched Door Lock/Unlock Wiring Detail; In this application, the
  • Page 22 – METHOD 1
  • Page 23 – guide under heading of hood switch.; METHOD 2; Pin Upgrade Data Bus/Flash Logic Module:; DO NOT RELEASE THIS VEHICLE TO THE CONSUMER UNTIL YOU CONFIRM THE
Loading the manual

128-7857

1 of 24

1

SELECTABLE FEATURES

The selectable features can be set manually as explained below, or with the RF feature programmer.
To set features using the RF programmer, follow the instructions packaged with the programmer.
Factory default settings are indicated by bold text.

Note :

The method of manual override can either be selected to operate from the valet switch or operate as custom code.

Be certain to place a check mark indicating the method used in the box located on the last page of the owner's manual.
NOTE: Keyless Entry Models with no horn output will Flash the Parking Lights instead of chirp where chirp is indicated.
Also, No data will be indicated if a feature is not available for a particular model. The unit will enter the feature but no selection will be available.

RF Programmable Feature Bank 1 Is For Transmitter Programming See Transmitter Programming Guide.

RF Programmable Features Bank 2 Is Alarm Selectable Features:

Feature Selection

1 Chirp

2 Chirps

3 Chirps

4 Chirps

5 Chirps

6 Chirps

1st DoorL/UL

1 Sec.

3.5 Sec.

1 Sec L, Dbl. U/L

Dbl L, 1 Sec UL

Dbl L, Dbl UL

1 S l/350mS ul

2nd Accy Lock

Auto Lock On

Auto Lock Off

3rd Accy. UL

Auto UL Dr.

Auto UL All

Auto UL Off

4th Headlights

Not Available

5th Passive Locks

Passive

Active

6th Pass/Act Arm

Passive Arm

Active Arm

7th Siren/Horn

Siren/Horn

Siren Only

Horn Only

8th Horn Chirp

10mS

16mS

30mS

40mS

50mS

9th O/R Method

Custom Code

Va l e t

10th 2 Step U/L

On

Off

11th Chp Del Tx

On

Off

12th Volts/HdWire

Not Available

13th Trigger Circuits

Not Available

14th L/UL Poll

Not Available

15th Aux Channel 5 Select

P u l s e d

Push & Hold

10 Seconds

20 Seconds

Latch On/Off

Hold 3.5 Sec For O/P

16th Aux Channel 6 Select

P u l s e d

Push & Hold

10 Seconds

20 Seconds

Latch On/Off

Hold 3.5 Sec For O/P

17th Aux Channel 7 Select

P u l s e d

Push & Hold

10 Seconds

20 Seconds

Latch On/Off

Hold 3.5 Sec For O/P

18th Trigger Delay

Not Available

When using the RF programmer, enter the program mode as follows:

Turn the ignition on.
Press and release valet switch 3 times;
turn ignition off then on.
Press and hold valet switch for 5 seconds.

Siren chirps 2 times indicating access to RF feature program mode.

Model PRO-9776

Installation Manual

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 4 - This Remote Start/Alarm System is designed to be used with; Automatic Transmission Vehicles Only!; . If the diesel engine has a; MUST HAVE a Tach Signal; INSTALLATION OF THE MAJOR COMPONENTS:; HOOD AND TRUNK PIN SWITCHES:

128-7857 4 of 24 4 This Remote Start/Alarm System is designed to be used with Automatic Transmission Vehicles Only! The unit provides a selectable ignition control that allows a number of selectable timed outputs for glow plug pre-heat which may be required for certain diesel vehicles, (see selectab...

Page 5 - only! Although this combination; IT MUST NOT; be installed

128-7857 5 of 24 5 THE RECEIVER/ANTENNA ASSEMBLY: The Superheterodyne Receiver Antenna Assembly provided with this unit allows routing from below the dashboard for maximum operating range. Choose a location above the belt line (dashboard) of the vehicle for bestreception. Special considerations must...

Page 6 - YELLOW START WIRE DETAIL; Ignition 1 Output

128-7857 6 of 24 6 YELLOW WIRE: Starter Output Careful consideration for the connection of this wire must be made to prevent the vehicle fromstarting while in gear. Understanding the difference between a mechanical and an electrical Neu-tral Start Switch will allow you to properly identify the circu...

Other Jackson Models

All Jackson Other