Ingersoll Rand 72654XD - Manual
Ingersoll Rand 72654XD – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – AIR AND LUBE REQUIREMENTS; WARNING; HAZARDOUS PRESSURE. Do not exceed maxiĆ; INSTALLATION
- Page 3 – FIGURE 2; LOWER PUMP; PARTS LIST; keep primer in place.
- Page 4 – TROUBLE SHOOTING; pressure in pump. Remove Obstruction in system.
OPERATOR’S MANUAL
INCLUDING:ĂSER VICE KITS, GENERAL DESCRIPTION & TROUBLESHOOTING
BASIC PUMP
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
3” AIR MOTOR
50:1 RATIO
2 1/4” STROKE
ALSO INCLUDE MANUALS: 6641X-X AIR MOTOR MANUAL, FORM 3637-2GENERAL INĆ
FORMATION SHEET.
400 LB DRUM
72643–D
72654–X–D
35 LB DRUM
72643–D
RELEASED: 6–21–95
(REV. A) IPP/PSE
72654–X–D
SERVICE KITS
•
Use only genuine ARO
R
replacement parts to assure compatible
pressure rating and longest service life.
•
637066-B for repair of Air Motor section.
•
60520 for repair of Lower Pump section.
GENERAL DESCRIPTION
This model is designed for delivery of heavy viscosity fluids such as
chassis lubrication fluids. Material dispensing accessories and supply
lines and fittings must be capable of withstanding pressures developed
by pump.
•
The ARO 50:1 ratio basic pump assembly consists of a 3" air motor
and lower pump end.
RATIO x REGULATED AIR PRESSURE TO AIR MOTOR = MAXIMUM FLUID
PRESSURE.
•
The 50:1 ratio is an expression of the relationship between the air
motor area and the lower pump end area. When 150 p.s.i. (10 bar)
air pressure is supplied to the air motor, the lower pump end will
develop a maximum of 7,500 p.s.i. (517 bar) fluid pressure (at no
flow) - as the fluid control is opened, the flow rate will increase as
the air motor cycle rate increases to keep up with the demand.
PUMP DATA
Air Motor
FIGURE 1
66410
1/2 NPT
Mat’l Outlet
Mat’l Inlet
Lower Pump
Model No. ``A"
``B"
72643-D
72654-D
27.3"
``A"
``B"
44.2"
19.1"
36"
(693.4 mm)
(1123.9 mm)
(485.1 mm)
(918.4 mm)
72654-1-D 44.5"
36.2"
(924.7 mm) (1130.2 mm)
OPERATING AND SAFETY PRECAUTIONS
•
HEED ALL WARNINGS.
•
DO NOT EXCEED MAXIMUM WORKING PRESSURE OF 7,500 PSI (517
BAR) AT 150 PSI (10 BAR) AIR INLET PRESSURE.
WARNING
: HIGH PRESSURE DEVICE. Improper usage of
this equipment could result in serious injury. The possibility
of injection into the flesh is a potential hazard. Never allow any
part of the human body to come in front of or in direct contact
with the material outlet. An injection injury can be serious. If
injection should occur, contact a qualified physician immediĆ
ately for treatment.
•
COMPONENTRUPTURE.
This pump is capable of producing high material
pressure as stated on pump model plate.
•
Be sure material hoses and other components are able to withstand fluid
pressures developed by this pump.
•
Do not operate pump continuously at speeds in excess of 75cycles per minĆ
ute.
WARNING
: PREVENT STATIC SPARKING. If static sparking
occurs, fire or explosion could result. Pump, dispensing
valve and containers must be grounded when handling inĆ
flammable fluids such as petroleum products, paints, lacĆ
quers, etc. and wherever discharge of static electricity is a
hazard.
•
Use grounded hoses (static wire) and be sure the object is grounded if it can
produce a static charge.
•
Use grounded hoses (static wire) and be sure the object is
grounded if it can produce a static charge.
•
Disconnect air line from pump air motor when system sits idle for long periĆ
ods of time.
THE ARO CORPORATION
D
ONE ARO CENTER
D
BRYAN, OHIO 43506–0151
E
1995 THE ARO CORPORATION
D
PRINTED IN U.S.A.
&
(419) 636–4242
D
FAX (419) 636–2115
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
72643-X-D Page 2of 4 AIR AND LUBE REQUIREMENTS WARNING HAZARDOUS PRESSURE. Do not exceed maxiĆ mum inlet air pressure of 150 psi (10 bar). Operating pump at higher pressure may cause pump damage and/or personal injuĆ ry and/or property damage. • Refer to general information sheet for additional safe...
72643-X-D Page 3 of 4 FIGURE 2 1 2 3 4 5 6 7 8 9 10 11 12131415 16 17 18 192021 22 23 FLUID PASSAGE 24 LOWER PUMP PARTS LIST ITEM Description Qty Part No. 1 Gasket 1 70834 2 Rod (72643-D) 1 72645 Rod (72654-D) 1 72641 Rod (72654-1-D) 1 72641-1 3 Nut 2 Y11-106-C 4 Tube (72643-D) 1 72644 Tube (72654-D...
72643-X-D Page 4 of 4 TROUBLE SHOOTING No Material. (Stalled Pump.) • Obstructed Material Line. Disconnect air supply. Relieve all fluid pressure in pump. Remove Obstruction in system. No Material (Pump Continually Cycles.) • Empty material supply. Shut down system. Replenish material supply. Materi...