Ingersoll Rand 72654XD - Manuals

Ingersoll Rand 72654XD – Manual in PDF format online.

Manuals:

1 Page 1
2 Page 2
3 Page 3
4 Page 4

Summary

Page 2 - AIR AND LUBE REQUIREMENTS; WARNING; HAZARDOUS PRESSURE. Do not exceed maxiĆ; INSTALLATION

72643-X-D Page 2of 4 AIR AND LUBE REQUIREMENTS WARNING HAZARDOUS PRESSURE. Do not exceed maxiĆ mum inlet air pressure of 150 psi (10 bar). Operating pump at higher pressure may cause pump damage and/or personal injuĆ ry and/or property damage. • Refer to general information sheet for additional safe...

Page 3 - FIGURE 2; LOWER PUMP; PARTS LIST; keep primer in place.

72643-X-D Page 3 of 4 FIGURE 2 1 2 3 4 5 6 7 8 9 10 11 12131415 16 17 18 192021 22 23 FLUID PASSAGE 24 LOWER PUMP PARTS LIST ITEM Description Qty Part No. 1 Gasket 1 70834 2 Rod (72643-D) 1 72645 Rod (72654-D) 1 72641 Rod (72654-1-D) 1 72641-1 3 Nut 2 Y11-106-C 4 Tube (72643-D) 1 72644 Tube (72654-D...

Page 4 - TROUBLE SHOOTING; pressure in pump. Remove Obstruction in system.

72643-X-D Page 4 of 4 TROUBLE SHOOTING No Material. (Stalled Pump.) • Obstructed Material Line. Disconnect air supply. Relieve all fluid pressure in pump. Remove Obstruction in system. No Material (Pump Continually Cycles.) • Empty material supply. Shut down system. Replenish material supply. Materi...