Table of Contents:

  • Page 2 – FIGURE 2; MAINTENANCE
  • Page 3 – PARTS LIST / LOWER PUMP SECTION; FIGURE 3; PUMP REASSEMBLY; Thread rod assembly into piston rod of air motor.
  • Page 4 – TROUBLE SHOOTING; pressure in pump. Remove Obstruction in system.
Loading the manual

OPERATOR’S MANUAL

RELEASED:

8--1--95

REVISED:

6--4--10

(REV. C)

4--1/4” AIR MOTOR

46:1 RATIO

0 -- 6900 PSI RANGE

INCLUDE MANUAL: S--633 GENERAL INFORMATION (PN 97999--625)

INCLUDING: SPECIFICATIONS, SERVICE KITS, PARTS, TROUBLESHOOTING

BASIC PUMP

CHOP--CHECK TYPE

READ THIS MANUAL CAREFULLY BEFORE INSTALLING,

OPERATING OR SERVICING THIS EQUIPMENT.

It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.

65875--XC

SERVICE KITS

Use only genuine ARO

R

replacement parts to assure compatible

pressure rating and longest service life.

61268 for repair of Air Motor section.

Service Note: The Air Motor Service/Parts Manual is not shipped

with the pump but it is included with each Service Kit. If this Service/

Parts Information is needed, request the Air Motor Operator’s Manu-

al from ARO. (Manual 6544X--X, PN 97999--64).

637056 for repair of Lower Pump section (Leather Packings).

637057 for repair of Lower Pump section (PTFE Packings).

637280 for repair of Lower Pump section (UHMW- PE Pack-

ings).

SPECIFICATIONS

Model Series

66875--XC

. . . . . . . . . . . . . .

Type

Air Operated, Basic Pump

. . . . . . . . . . . . . . . . . . . .

Chop--Check

Ratio

46:1

. . . . . . . . . . . . . . . . . . . .

Air Motor Diameter

4--1/4’’ (108 mm)

. . . . . . . . .

Stroke

4’’ (102 mm)

. . . . . . . . . . . . . . . . . .

Air Inlet

1/2” -- 14 NPTF -- 1 (f)

. . . . . . . . . . . . . . . . .

Material Inlet

Immersed or Follower Plate

. . . . . . . . . . . . .

Material Outlet

1/2” -- 14 NPTF -- 1 (f)

. . . . . . . . . . .

Pump Construction

Carbon Steel

. . . . . . .

Dimensional Data

See Fig.1

. . . . . . . . . .

PERFORMANCE

Air Inlet Pressure Range

0 -- 150 PSI (0 -- 10.3 bar)

. . . . .

Fluid Pressure Range

0 -- 6900 PSI (0 -- 475 bar)

. . . . . . .

Displacement In

3

Per Cycle

2.5

. . .

Cycles Per Gallon

92.8

. . . . . . . . . .

Noise Level

* -- 81.8 db(A) @ 60 psi, 40 cycles per minute

*

The pump sound pressure level has been updated to an Equivalent Continuous Sound

Level (L

Aeq

) to meet the intent of ANSI S1. 13--1971, CAGI--PNEUROP S5.1 using four

microphone locations.

GENERAL DESCRIPTION

This model is designed for delivery of heavy viscosity fluids such as

grease. Material dispensing accessories and supply lines and fittings

must be capable of withstanding pressures developed by pump.

OPERATING AND SAFETY PRECAUTIONS

WARNING

Read the General Information Manual for operat-

ing and safety precautions and important information.

PUMP DATA

FIGURE 1

Air Inlet (female)

1/2” -- 14 NPTF

Material Outlet (female)

1/2” -- 14 NPTF

NOTE: Dimensions are shown in inches and (mm), supplied for reference only

and are typically rounded up to the nearest 1/16 inch.

Air Motor

65445--B

Mat’l Inlet

(Immersed)

65873--X

Lower Pump

35 11/32”

(897.7 mm)

21 15/32”

(545.3 mm)

See Fig. 2

65875- XC BASIC PUMP

65874 Adapter Kit

IMPORTANT

This is one of two documents which support the pump.

Replacement copies of these forms are available upon request.

=

65875- XC

MODEL OPERATOR’S MANUAL

-

S- 633

GENERAL INFORMATION LUBRICATION PISTON PUMPS

INGERSOLL RAND COMPANY LTD

209 NORTH MAIN STREET – BRYAN, OHIO 43506

(800) 495-0276

FAX

(800) 892-6276

© 2010

www.ingersollrandproducts.com

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - FIGURE 2; MAINTENANCE

PAGE 2 OF 4 INSTALLATION FLUSH PUMP 1. Connect fluid hose to pump outlet and be sure all fittings are tight. 2. Turn air regulator knob counter--clockwise until it turns freely. 3. Pump has been tested in oil and a small amount remains for protec- tion against rusting. Immerse lower pump end in comp...

Page 3 - PARTS LIST / LOWER PUMP SECTION; FIGURE 3; PUMP REASSEMBLY; Thread rod assembly into piston rod of air motor.

PAGE 3 OF 4 PARTS LIST / LOWER PUMP SECTION FIGURE 3 1 23 4 5 6 7 8 9 1011 1213 14 15 16 17 18 19 20 APPLY LOCTITE 271 TO THREADS : : 21 : ITEM Description Qty Part No. 1 Washer 1 90747 2 Female Washer 1 90748 n 3 Packing (65873) Leather 5 93714- 1 Packing (65873- 1) PTFE 5 93714- 2 Packing (65873- ...

Page 4 - TROUBLE SHOOTING; pressure in pump. Remove Obstruction in system.

PAGE 4 OF 4 TROUBLE SHOOTING No Material. (Stalled Pump.) • Obstructed Material Line. Disconnect air supply. Relieve all fluid pressure in pump. Remove Obstruction in system. No Material (Pump Continually Cycles.) • Empty material supply. Shut down system. Replenish material sup- ply. Material on on...