Page 2 - FIGURE 2; MAINTENANCE

PAGE 2 OF 4 INSTALLATION FLUSH PUMP 1. Connect fluid hose to pump outlet and be sure all fittings are tight. 2. Turn air regulator knob counter--clockwise until it turns freely. 3. Pump has been tested in oil and a small amount remains for protec- tion against rusting. Immerse lower pump end in comp...

Page 3 - PARTS LIST / LOWER PUMP SECTION; FIGURE 3; PUMP REASSEMBLY; Thread rod assembly into piston rod of air motor.

PAGE 3 OF 4 PARTS LIST / LOWER PUMP SECTION FIGURE 3 1 23 4 5 6 7 8 9 1011 1213 14 15 16 17 18 19 20 APPLY LOCTITE 271 TO THREADS : : 21 : ITEM Description Qty Part No. 1 Washer 1 90747 2 Female Washer 1 90748 n 3 Packing (65873) Leather 5 93714- 1 Packing (65873- 1) PTFE 5 93714- 2 Packing (65873- ...

Page 4 - TROUBLE SHOOTING; pressure in pump. Remove Obstruction in system.

PAGE 4 OF 4 TROUBLE SHOOTING No Material. (Stalled Pump.) • Obstructed Material Line. Disconnect air supply. Relieve all fluid pressure in pump. Remove Obstruction in system. No Material (Pump Continually Cycles.) • Empty material supply. Shut down system. Replenish material sup- ply. Material on on...