Page 5 - Laser Emulation
1 I NTRODUCTION The MS5145 Eclipse ™ is a single-line, hand-held laser scanner. Equipped with Metrologic’s patented CodeGate ® technology, Eclipse can be used in a wide variety of applications. CodeGate technology allows the user to easily target the desired bar code and complete the data transmissi...
Page 6 - Scanner and Accessories; ASIC; PTIONAL; Description
2 I NTRODUCTION Scanner and Accessories B ASIC K IT Part # Description MS5145 Eclipse Scanner 00-02544 x MetroSelect Single-Line Configuration Guide * 70-79016 x MS5100 Eclipse Series Installation and User’s Guide * * Available on the Metrologic website - www.metrologic.com O PTIONAL A CCESSORIES Pa...
Page 7 - NTRODUCTION; Countertop Stand; Applicable for IBM
3 I NTRODUCTION Scanner and Accessories O PTIONAL A CCESSORIES Part # Description 55-55000 x -3 RS232 PowerLink Cable with Built in Power Jack straight cord, long strain relief, black 55-55002 x -3 Keyboard Wedge PowerLink Cable with Adapter straight cord, long strain relief, black 55-55020 x -3 Sta...
Page 8 - Scanner Components; Figure 1. Scanner Components; Maintenance
4 I NTRODUCTION Scanner Components I TEM N O . D ESCRIPTION 1 Mode Select Button/CodeGate Button (see page 12) 2 Red LED (see page 14) 3 Green LED (see page 14) 4 Pin Hole for Cable Release (see page 6) 5 Red Output Window (Laser Aperture) 6 Speaker (see page 13) 7 10-Pin RJ45, Female Socket (see pa...
Page 9 - Caution and Serial Number Labels; Figure 2. Label Location on the Bottom of the Scanner with Example
5 I NTRODUCTION Caution and Serial Number Labels Figure 2. Label Location on the Bottom of the Scanner with Example Caution To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950...
Page 11 - RS232, Light Pen or Laser Emulation; Emulation Connections
7 I NSTALLATION RS232, Light Pen or Laser Emulation 1. Turn off the host system. 2. Plug the male, 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS5145. 3. Connect the 9-Pin female end of the PowerLink cable to the appropriate communication port on the host device. 4. Plug the...
Page 13 - Figure 8. Keyboard Wedge Connections
9 I NSTALLATION Keyboard Wedge 1. Turn off the host system. 2. Plug the male, 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS5145. 3. Disconnect the keyboard from the host/PC. 4. Connect the Y ends of the PowerLink cable to the keyboard and the host’s keyboard port. If necess...
Page 14 - NSTALLATION; Stand-Alone Keyboard; Connect the PowerLink cable to the; Connection
10 I NSTALLATION Stand-Alone Keyboard 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connector into the jack on the Eclipse. There will be a ‘click’ when the connection is made. If the scanner is receiving power from the host system, skip to step #5. 3. Connect the L-shaped plug of the...
Page 16 - How to Use CodeGate and the Manual Activation Mode; ODE; Two Modes of Operation
12 S CANNER O PERATION How to Use CodeGate and the Manual Activation Mode C ODE G ATE ® M ANUAL A CTIVATION M ODE * * This feature is not a default setting. Refer to the MetroSelect Configuration Guide for instructions on enabling the Manual Activation Mode. Figure 11. CodeGate Enabled Figure 12. Ma...
Page 17 - Indicators; This is a failure indicator. Refer to the
13 S CANNER O PERATION Indicators Audible When the MS5145 scanner is operational, the scanner provides audible feedback to indicate the status of the scanner and the last scan. Eight settings are available for the tone of the beep (normal, six alternate tones and no tone). For instructions on how to...
Page 18 - Figure 13. LED Color and Location; After a period of inactivity, the
14 S CANNER O PERATION Indicators Visual The MS5145 is equipped with a red LED and green LED which indicate the scanner’s state and the status of the current scan when the unit is in operation. Figure 13. LED Color and Location Green and Red LEDs Are Off The LEDs will not be illuminated if the scann...
Page 19 - Failure
15 S CANNER O PERATION Indicators Failure One Razzberry Tone – On Power Up This indicates the scanner has experienced a laser or flipper subsystem failure. Return the unit for repair to a Metrologic Authorized Service Center. Continuous Razzberry Tone with no LEDs If, upon power up, the scanner emit...
Page 20 - Depth of Field vs. Minimum Bar Code Element Width; Minimum Bar Code Element Width; Figure 14. Depth of Field vs. Minimum Bar Code Element Width
16 S CANNER O PERATION Depth of Field vs. Minimum Bar Code Element Width Minimum Bar Code Element Width A B C D E F mm .10 .12 .17 .26 .33 .66 mils 4.1 4.8 6.8 10.4 13 26 Figure 14. Depth of Field vs. Minimum Bar Code Element Width
Page 21 - Configuration Modes; Bar Codes; MetroSet
17 S CANNER O PERATION Configuration Modes The MS5145 Eclipse has three modes of configuration. • Bar Codes The Eclipse can be configured by scanning the bar codes located in the MetroSelect ® Single-Line Configuration Guide ( MLPN 00-02544). This manual can be downloaded FREE at www.metrologic.com....
Page 23 - FEATURE; This example illustrates two important points.; Character
19 S CANNER O PERATION EXAMPLE #3: The following example shows the events that occur when an invalid bar code is sent. This sample will load the factory default settings and then set the baud rate to 19200. FEATURE HOST COMMAND ASCII REPRESENTATION SCANNER RESPONSE Enter Configuration Mode [stx]9999...
Page 24 - Symptoms; All Interfaces
20 T ROUBLESHOOTING G UIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-Metro or 1-800-436-3876 to preserve the limited warranty terms. Symptoms Possible Causes Solution All Interfaces No power is being supplied to the unit. Check the transforme...
Page 25 - RS232 & Serial Emulation USB Interfaces
21 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The unit powers up, but does not scan and/or beep. The unit is trying to scan a particular symbology that is not enabled. UPC/EAN, Code 39, interleaved 2 of 5, Code 93, Code 128 and Codabar are enabled by default. Verify the type of bar co...
Page 26 - The computer is in
22 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The unit scans but the data is not correct. The unit’s configuration is not correct. Make sure that the proper PC type AT, PS2 or XT is selected. Verify the correct country code and data format is selected. Adjust the inter-character delay...
Page 28 - Specifications subject to change without notice.
24 D ESIGN S PECIFICATIONS MS5145 Eclipse O PERATIONAL Light Source: V isible L aser D iode (VLD) @ 650 nm Laser Power: Less than 1.0 mW average Depth of Scan Field: 0 mm – 140 mm (0" – 5.5") 0.33 mm (13 mil) Bar Code Scan Speed: 72 ± 2 scan lines per second Scan Pattern: Single scan line Mi...
Page 29 - LECTRICAL; For regulatory compliance information, see pages 37 – 39.; NVIRONMENTAL
25 D ESIGN S PECIFICATIONS MS5145 Eclipse E LECTRICAL Input Voltage: 5VDC ± 0.25V Power: Operating 675 mW Current: Operating 135 mA average @ 5VDC DC Transformers: Class II; 5.2VDC @ 1A For regulatory compliance information, see pages 37 – 39. E NVIRONMENTAL Operating 0°C to 40°C (32°F to 104°F) Tem...
Page 30 - Keyboard Type; see pages 27 - 29 for additional information
26 A PPLICATIONS AND P ROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. Scanner Version Identifier Communication Protocol(s) 00 Laser Emulation 11 RS485 S RS232 - TXD, RXD, RTS, CTS 38 Low Speed USB, Serial Emulation or Keyboard Emula...
Page 36 - ROM; Do not; POS Scanners
32 U PGRADING THE F LASH ROM F IRMWARE The MS5145 is part of Metrologic's line of scanners with flash upgradeable firmware. The upgrade process requires a new firmware file supplied to the customer by a customer service representative and Metrologic's MetroSet 2 software . A personal computer runnin...
Page 37 - Scanner Pinout Connections
33 S CANNER AND C ABLE T ERMINATIONS Scanner Pinout Connections The MS5145 scanner interfaces terminate to a 10-pin modular jack. The serial number label indicates the interface enabled when the scanner is shipped from the factory. Figure 15. MS5145-41 RS232C and Light Pen Emulation Pin Function 1 G...
Page 39 - Cable Connector Configurations
35 S CANNER AND C ABLE T ERMINATIONS Cable Connector Configurations RS232 PowerLink Cable, 55-55000 x -3 Pin Function 1 Shield Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 DTR Input/Light Pen Source 5 Power/Signal Ground 6 Light Pen Data (DSR Out for -14 interfaces) 7 CTS Input 8 RTS Outpu...
Page 41 - Safety; aumenta il rischio di
37 R EGULATORY C OMPLIANCE Safety ITE Equipment IEC 60950-1, EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure. Under no circ...
Page 42 - EMC; Emissions; length when fully extended.; Class A Devices; Notice; This Class A digital apparatus complies with Canadian ICES-003.; Remarque
38 R EGULATORY C OMPLIANCE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 NOTE: Immunity performance is not guaranteed for scanner cables greater than 3 meters in length when fully extended. Changes or modifications not expressly approved by the party responsible...
Page 43 - Standard Europeo; Class B Devices; Folgendes trifft zu, wenn das Scannerkabel kürzer als 3 Meter ist; Reorient or relocate the receiving antenna; This Class B digital apparatus complies with Canadian ICES-003.
39 R EGULATORY C OMPLIANCE EMC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Standard Europeo Attenzione Questo e’ un prodotto di classe A. Se usato in vicinanza di residenze private potrebbe causare ...
Page 44 - Metrologic Eria Ibérica, SL; MTLG; Suzhou Sales Office
40 L IMITED W ARRANTY The MS5145 Eclipse ™ scanners are manufactured by Metrologic at its Suzhou, China facility. The MS5145 Eclipse scanners have a three (3) year limited warranty from the date of manufacture. Metrologic warrants and represents that all MS5145 Eclipse scanners are free of all defec...
Page 45 - ATENTS
41 P ATENTS This METROLOGIC product may be covered by, but is not limited to, one or more of the following U.S. Patents: U.S. Patent No.; 5,216,232; 5,260,553; 5,340,971; 5,424,525; 5,484,992; 5,525,789; 5,528,024; 5,616,908; 5,627,359; 5,661,292; 5,777,315; 5,789,730; 5,789,731; 5,811,780; 5,828,04...
Page 46 - NDEX
42 I NDEX A AC .................................. see power accessories ............................... 2, 3 aperture ......................................... 4 B beeper ......................... see indicator button ...................................... 4, 12 Button .................................