INSTALLATION ADDENDUM

69-2576-01

Wiring Configuration

ADVANCED MODELS (HE150/HE250/HE300)

Fig. 1. Wiring H8908 to humidify only with a call for heat or fan.

Fig. 2. Wiring TrueIAQ, VisionPRO IAQ, or Prestige, using the intelligent control to program humidity calls with heat,

cool, or on demand.

HE150 OR HE250

DIP SWITCH SETTING

RESET POWER AFTER

ANY DIP SWITCH CHANGES

HE300

H8908

10

OFF

ON

20

30

40

50

60

M29938A

POWER IN

G OR W

C

OR

AIR PROVING

DEVICE

HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN.

HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN.

CONNECT G TO HUMIDIFY WHEN THERE IS A FAN CALL.

CONNECT W TO HUMIDIFY WHEN THERE IS A HEAT CALL.

NEVER CONNECT BOTH. CONNECT C WHEN USING G OR W.

USE AIR PROVING DEVICE INSTEAD OF THE G/W CONNECTION

TO HUMIDIFY ANY TIME THE FAN IS OPERATING.

1

1

2

3

3

2

HE300 USES A LINE CORD PLUG.

CONNECT G TO HUMIDIFY WHEN THERE IS A FAN CALL.

CONNECT W TO HUMIDIFY WHEN THERE IS A HEAT CALL.

NEVER CONNECT BOTH. CONNECT C WHEN USING G OR W.

USE AIR PROVING DEVICE INSTEAD OF THE G/W CONNECTION

TO HUMIDIFY ANY TIME THE FAN IS OPERATING.

1

3

2

H8908

10

OFF

ON

20

30

40

50

60

POWER IN

G OR W

C

AIR PROVING

DEVICE

1

2

3

OR

M29939A

FROM

HUMIDITY

CONTROL

HE150 OR HE250

DIP SWITCH SETTING

RESET POWER AFTER

ANY DIP SWITCH CHANGES

HE300

POWER IN

HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN.

HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN.

1

1

HE300 USES A LINE CORD PLUG.

1

POWER IN

FROM

HUMIDITY

CONTROL

1

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - WIRING CONFIGURATION; Fig. 4. Wiring to force fan on and prove airflow in the duct.; POWER IN

WIRING CONFIGURATION 69-2576—01 2 Fig. 3. Wiring to force the HVAC system fan on whenever humidity is needed (on demand). Fig. 4. Wiring to force fan on and prove airflow in the duct. M29940A G (FURNACE) G (THERMOSTAT) ONLY NEEDED IF SYSTEM’S THERMOSTAT DOES NOT ISOLATE Y FROM G. IF NEEDED, BREAK TH...

Page 3 - PROVIDE DISCONNECT MEANS AND

WIRING CONFIGURATION 3 69-2576—01 BASIC MODELS (HE100/HE200) Fig. 5. Wiring H8908 with fan interlock. Fig. 6. Wiring H8908 with 2-speed fan motor. H8908 1 2 HUMIDIFIER TRANSFORMER FURNACE FAN MOTOR FAN CONTROL L1 (HOT) L2 M29945A POWER SUPPLY 10 OFF ON 20 30 40 50 60 1 2 PROVIDE DISCONNECT MEANS AND...

Page 4 - Automation and Control Solutions; POWER SUPPLY. PROVIDE DISCONNECT; POWER SUPPLY. PROVIDE DISCONNECT MEANS; TRANSFORMER

WIRING CONFIGURATION Automation and Control Solutions Honeywell International Inc.1985 Douglas Drive NorthGolden Valley, MN 55422 Honeywell Limited-Honeywell Limitée35 Dynamic DriveToronto, Ontario M1V 4Z9customer.honeywell.com ® U.S. Registered Trademark© 2011 Honeywell International Inc.69-2576—01...

Other Honeywell Models