Honeywell F300- User Manual
Honeywell F300– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Fractional Efficiency:
- Page 5 – PLANNING THE INSTALLATION; Application; Applications with Air Conditioning
- Page 6 – WARNING; Heavy Equipment Hazard.
- Page 7 – Fig. 3. Mounting positions with variety of furnace installations.; Determine Duct Design Requirements; Transitions
- Page 8 – Offsets; Fig. 5. Typical use of duct offset to allow space for; INSTALLATION; Electric Shock Hazard.; Unpack Electronic Air Cleaner
- Page 9 – Install Turning Vanes; vanes. Locking pliers hold duct to air cleaner cabinet; Seal Joints; Fig. 8. Position of cell key determines orientation of cell; Attach Cell Handles; Fig. 9. Install the handle on the end of the cell closest to
- Page 10 – Reassemble Air Cleaner
- Page 11 – OPERATION; Inspect the Installation
- Page 12 – Check Air Cleaner Operation; SERVICE; Can cause personal injury.; Automatic Dishwasher; CAUTION; Can cause personal injury.; Do not allow the dishwasher to run through the dry
- Page 13 – Washing Cells in a Container; Washing Cells at the Car Wash
- Page 14 – Replacing Ionizer Wires; Fig. 16. Use ohmmeter to check electronic cells for short; Modification to Reduce Ozone Odor
- Page 17 – Description
- Page 18 – Part Numbers are keyed to Parts List.
- Page 19 – PARTS AND ACCESSORIES NOT ILLUSTRATED (TABLE 5); Table 5. Parts and Accessories Not Illustrated.
- Page 20 – SERVICE REMINDER SCHEDULE; YEAR
- Page 22 – Automation and Control Solutions
- Page 23 – DONNÉES TECHNIQUES; Filtre à air électronique F300; APPLICATION; CARACTÉRISTIQUES; Table des matières
- Page 25 – Température Ambiante Nominale :; Pièces de rechange :
- Page 27 – PLANIFICATION DE L’INSTALLATION; MD
- Page 28 – Choix de la position d’installation; AVERTISSEMENT; Peut causer des blessures ou endommager
- Page 30 – Nettoyer le compartiment du ventilateur
- Page 31 – Sceller les joints
- Page 32 – Réassembler le filtre à air; Risque de choc électrique; Fig. 10. Schéma interne du filtre à air électronique avec le W8600F.
- Page 33 – Fig. 12. Connexion des conducteurs du filtre à air; FONCTIONNEMENT; Vérifier l’installation
- Page 34 – MAINTENANCE; Nettoyage des cellules et des préfiltres; Nettoyage des cellules dans le lave-vaisselle; MISE EN GARDE; Nettoyage des cellules dans un bac; MISE EN GARDE
- Page 35 – Nettoyage des cellules dans un lave-auto
- Page 36 – Fig. 16. Utiliser un ohmmètre pour vérifier s’il y a des; Réduction de l’odeur d’ozone; Risque de choc électrique.
- Page 41 – PIÈCES ET ACCESSOIRES NON ILLUSTRÉS (TABLEAU 4)
- Page 42 – CALENDRIER DE RAPPEL DU LAVAGE; ANNÉE
- Page 44 – Solutions de régulation et d’automatisation; Honeywell
PRODUCT DATA
68-0240EF-5
F300 Electronic Air Cleaner
APPLICATION
The F300 Electronic Air Cleaner is mounted in the return air
duct of a forced air heating, cooling, or ventilating system. It
captures a significant amount of the airborne particles 0.3
micron and larger from air circulated through it.
FEATURES
• Media postfilters (optional) provide enhanced filtration.
• Available in five sizes to fit most ducts; adapts to
airflow from either side.
• Capacity varies from 1000 cfm (2040 m
3
/hr) to 2000 cfm
(3400 m
3
/hr), depending on size.
• Solid state power supply is self-regulating and
maintains peak efficiency during a wide range of cell
dirt loading conditions.
• Low pressure drop.
• Optional W8600F Air Cleaner Monitor indicates air
cleaner performance, reminds homeowner when filter
and cell maintenance are due and when to check the
system.
• Optional wireless W8600A AIRWATCH™ LCD indicator
provides reminder when air cleaner electronic cells
need washing, when media postfilters need replacing,
when UV lamps need replacing and when humidifier
pad needs replacing.
• Galvanized cabinet protects against rust.
• Neon light next to on-off switch tells if air cleaner is
powered and if high voltage is present.
• Prefilter screens protect cells from large dirt particles.
• Test button checks system operation.
Contents
Application/Features..........................................................
Specifications/Ordering Information ..................................
Installation ........................................................................
Operation .......................................................................... 11
Checkout .......................................................................... 11
Service ............................................................................. 12
Replacement Parts/Exploded View ................................... 17
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Other Manuals for Honeywell F300
Summary
F300 ELECTRONIC AIR CLEANER 68-0240EF-5 2 ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number. If you have additional questions, need further informati...
F300 ELECTRONIC AIR CLEANER 5 68-0240EF-5 Fig. 2. Electronic air cleaner installation dimensions in in. (mm). PLANNING THE INSTALLATION Application The F300 Electronic Air Cleaner is used in a forced air heating, cooling, or ventilating system. It removes airborne particles from the air circulated t...
F300 ELECTRONIC AIR CLEANER 68-0240EF-5 6 Applications with a Humidifier An evaporative humidifier can be mounted upstream from the air cleaner. An atomizing humidifier should be mounted downstream from the air cleaner, even though hard water salts will be blown into the living space and deposited a...