Hisense HT007E - User Manual

Hisense HT007E

Hisense HT007E – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
Page: / 41

Table of Contents:

  • Page 8 – Dynamic Frequency Selection
  • Page 9 – Parameters of radar test waveforms
  • Page 10 – Radar Waveform Calibration Procedure:
  • Page 11 – EUT is not support TPC and not with Radar detection.
  • Page 12 – period; Block diagram of test setup Test Procedure:
  • Page 14 – Test plots as follows:
  • Page 15 – Antenna Requirements; dBi are used, the power shall be reduced by the amount in dB that
  • Page 16 – Radiated Emission
  • Page 18 – MHz
  • Page 19 – FREQUENCY
  • Page 21 – produces highest emissions.
Loading the manual

Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE24071734-1E02

Page 128 of 277

10. Frequency Stability Measurement

10.1. Limit of Frequency Stability

Manufacturers of U-NII devices are responsible for ensuring frequency stability such that an
emission is maintained within the band of operation under all conditions of normal operation as
specified in the user’s manual.

10.2. Measuring Instruments

The measuring equipment is listed in the section 4 of this test report.

10.3. Test procedures

(1) To ensure emission at the band edge is maintained within the authorized band, those values
shall be measured by radiation emissions at upper and lower frequency points, and finally
compensated by frequency deviation as procedures below.
(2) The EUT was operated at the maximum output power, and connected to the spectrum analyzer,
which is set to maximum hold function and peak detector. The peak value of the power envelope
was measured and noted. The upper and lower frequency points were respectively measured
relatively 10 dB lower than the measured peak value.
(3) The frequency deviation was calculated by adding the upper frequency point and the lower
frequency point divided by two. Those detailed values of frequency deviation are provided in table
below.

10.4. Test setup

Appendix G: Frequency Stability

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 8 - Dynamic Frequency Selection

Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE24071734-1E02 Page 135 of 277 11. Dynamic Frequency Selection 11.1. Applicability of DFS requirements Table 1: Applicability of DFS Requirements Prior to Use of a Channel Requirement Operational Mode  Master  Client Without Radar Detect...

Page 9 - Parameters of radar test waveforms

Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE24071734-1E02 Page 136 of 277 11.2. Limit (1) DFS Detection Thresholds Table 3: DFS Detection Thresholds for Master Devices and Client Devices with Radar Detection Maximum Transmit Power Value (See Notes 1, 2, and 3) EIRP ≥ 200 milliwatt ...

Page 10 - Radar Waveform Calibration Procedure:

Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE24071734-1E02 Page 137 of 277 A minimum of 30 unique waveforms are required for each of the Short Pulse Radar Types 2 through 4. If more than 30 waveforms are used for Short Pulse Radar Types 2 through 4, then each additional waveform mus...

Other Hisense Models