Heat Controller HCG**V1E - Manual

Heat Controller HCG**V1E

Heat Controller HCG**V1E – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
Page: / 32

Table of Contents:

  • Page 2 – TAbLE OF CONTENTS
  • Page 3 – IMPORTANT SAFETY INFORMATION; WARNING; NITROGEN; HEALTH; • Before servicing, disconnect all electrical power
  • Page 4 – GENERAL INFORMATION; before You Install this Unit; INSTALLATION CLEARANCES; Operation of Air Handler During Construction
  • Page 5 – Installation in a Garage; Unconditioned Spaces
  • Page 6 – AIR HANDLER INSTALLATION; • The unit must be leveled at installation and attached to; Horizontal; Return
  • Page 7 – Figure 4. Unit Horizontally Suspended; Horizontal Installations; Horizontal Left Installations:; IMPORTANT: If the webbing is not removed, the
  • Page 8 – Refrigerant Line Connections; Recess; Figure 5. Circuit breaker Cover
  • Page 10 – Condensate Drainage; • Methods for disposing of condensate vary according; PVC or flexible tubing; Figure 9. Condensate Drainage Example
  • Page 11 – ELECTRICAL CONNECTIONS; • Verify proper operation after servicing.; Line Voltage
  • Page 12 – • The thermostat should be mounted about 5 feet above; Control board; Twinning; Please follow
  • Page 13 – STARTUP & ADjUSTMENTS; before You Start the Unit
  • Page 14 – • Terminal 4 = Hi speed
  • Page 15 – Dehumidification Options
  • Page 16 – • Before servicing, disconnect all electrical power
  • Page 17 – Detail D; Yes
  • Page 19 – AIRFLOW DATA; Dry Coil ESP
  • Page 21 – See Table 6 for appropriate switch settings for these airflows.
  • Page 23 – BLWDTC; CG; Figure 14. Single Stage Control board; ELECTRICAL DIAGRAMS & DATA
  • Page 24 – Figure 17. Variable Speed Motor Control board; RED; GREEN; Figure 16. Fixed Speed Motor Control board
  • Page 25 – Air Handler; MO
  • Page 26 – Air Handler with F
  • Page 27 – Air Handler with
  • Page 29 – Table 12. Control board Operation; None
  • Page 30 – Table 12. Control board Operation - Continued
  • Page 31 – CONTROL SIGNAL & MODE
  • Page 32 – INSTALLATION / PERFORMANCE CHECK LIST; INSTALLATION ADDRESS:; ATTENTION INSTALLERS:
Loading the manual

AIR HANDLER

Please read all information in this manual thoroughly and become familiar with the capabilities

and use of your appliance before attempting to operate or maintain this unit. These instructions

are primarily intended to assist qualified individuals experienced in the proper installation of

this appliance. Some local codes require licensed installation/service personnel for this type

of equipment. Improper installation, service, adjustment, or maintenance may cause explosion,

fire, electrical shock or other hazardous conditions which may result in personal injury or

property damage.

Unless otherwise noted in these instructions, only factory authorized kits or accessories may

be used with this product. Keep this manual where you have easy access to it in the future. If a

problem occurs, check the instructions and follow recommendations given. If these suggestions

don’t eliminate your problem, call your servicing contractor.

DO NOT DESTROY. PLEASE READ CAREFULLY AND

KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.

IMPORTANT

HMG**F1E, HMG**X1E & HCG**V1E Series

INSTALLATION INSTRUCTIONS

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TAbLE OF CONTENTS

2 IMPORTANT SAFETY INFORMATION .......................3 REqUIREMENTS & CODES .......................................3 GENERAL INFORMATION ..........................................4 Before You Install this Unit .........................................4 Locating the Air Handler ....................

Page 3 - IMPORTANT SAFETY INFORMATION; WARNING; NITROGEN; HEALTH; • Before servicing, disconnect all electrical power

3 IMPORTANT SAFETY INFORMATION INSTALLER: Please read all instructions before servicing this equipment. Pay attention to all safety warnings and any other special notes highlighted in the manual. Safety markings are used frequently throughout this manual to designate a degree or level of seriousness...

Page 4 - GENERAL INFORMATION; before You Install this Unit; INSTALLATION CLEARANCES; Operation of Air Handler During Construction

4 GENERAL INFORMATION This appliance has been tested for capacity and efficiency in accordance with AHRI Standards and will provide many years of safe and dependable comfort, providing it is properly installed and maintained. Abuse, improper use, and/or improper maintenance can shorten the life of t...

Other Heat Controller Models

All Heat Controller Other