Heat Controller BHD-501-G - Manual
Heat Controller BHD-501-G – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – BHD-G Service Manual; Portable Dehumidifier with R-410A; TABLE OF CONTENTS; Continuous Dehumidification mode
- Page 3 – SAFETY PRECAUTIONS; Inspect the service cord for damage or wear.; INSULATION RESISTANCE TEST; Water-full alarm and auto shutdown functions.; CONTROL LOCATIONS; Press to turn the dehumidifier on and off.
- Page 4 – Humidity Set Control; For drier air, press the; TIMER Set Control; Bucket is full-- Empty the bucket and replace in the right position.; OUTSIDE DIMENSIONS; Model
- Page 5 – Product Installation Instructions; the compressor to start up and for dehumidifaction to resume.; TURNING THE UNIT “ON” OR “OFF”; not be in use for a long period of time.); OPERATION WITH WATER TANK; indicator light will flash.; Pull out the bucket a
- Page 6 – OPERATION WITH CONTINUOUS DRAINAGE; On the rear of the unit, remove the rubber plug carefully.; Precaution; Be sure to unplug the unit before cleaning.
- Page 7 – Electronic function; the unit will stop anti-icing protection function.
- Page 8 – Basic Test Procedures; DEFECTIVE COMPRESSOR; Figure 1: Compressor winding test
- Page 9 – SEALED REFRIGERATION SYSTEM REPAIRS; EQUIPMENT REQUIRED; Accurate refrigerant charge measuring device such as:; EQUIPMENT MUST BE CAPABLE OF:; Introducing refrigerant charge into high side of the system.; HERMETIC COMPONENT REPLACEMENT; Cut the line below, pinch off the suction side of the compressor.; CHECKING THE INTERNAL OVERLOAD
- Page 10 – will prevent boiling the oil out of the crankcase.; NOTE; Determine that capacitor is serviceable.
- Page 11 – should be two times that of the first check if the capacitor is good.; remain there as long as the probes are connected.
- Page 12 – TROUBLESHOOTING GUIDE; tion, and the other is called the Structure Damage.; NAMEPLATE RATING; ROOM AIRCONDITIONER VOLTAGE LIMITS:; will restore operation in the previous mode.; Water level protection function abnormal; power indicator will flash at 5 Hz.
- Page 13 – Fail to start or fail to start motor
Heat Controller, Inc. • 1900 Wellworth Ave. • Jackson, MI 49203 • (517)787-2100 • www.heatcontroller.com
SERVICE MANUAL
Portable Dehumidifer Series
with R-410A:
BHD-301-G
BHD-501-G
BHD-651-G
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
BHD-G Service Manual Portable Dehumidifier with R-410A Heat Controller, Inc. 1 TABLE OF CONTENTS 1. PREFACE ............................................................................................ 2 1.1 SAFETY PRECAUTIONS ...................................................... 21.2 INSULATION RES...
Heat Controller, Inc. Portable Dehumidifier with R-410A BHD-G Service Manual 2 1. PREFACE This SERVICE MANUAL provides various servicing information for the unit, including the mechanical and electrical parts, etc. This dehumidifier was manufactured and assembled under a strict quality control syste...
BHD-G Service Manual Portable Dehumidifier with R-410A Heat Controller, Inc. 3 3. Humidity Set Control The humidity level can be set within a range of 35%RH (Relative Humidity) to 85%RH (Relative Humidity) in 5% increments. For drier air, press the button and set to a lower percent value(%). When th...