Table of Contents:

  • Page 2 – SERVICE MANUAL; SAFETY PRECAUTIONS; CONTENTS
  • Page 3 – STRUCTION; REMARK
  • Page 4 – • Designed for cooling only.; CONTROL LOCATIONS; • Built in adjustable THERMISTOR and THERMOSTAT.; • VENTILATION; PULL OPEN / PUSH CLOSE; TEMP; CAUTION
  • Page 5 – DISASSEMBLY INSTRUCTIONS; Figure 1; Figure 3
  • Page 6 – Figure 7; AIR HANDLING PARTS; Move the evaporator sideward carefully.; Figure 4
  • Page 7 – . Leave the valve in place after; Figure 9
  • Page 8 – If the supply cord of this appliance is damaged, it
  • Page 9 – REFRIGERATION CYCLE
  • Page 10 – NOTES
  • Page 11 – Figure 17A-Pulling Vacuum
  • Page 12 – INSTALLATION REQUIREMENTS; If you use an existing wall sleeve,; ELECTRICAL SERVICE; Air Conditioner; FRIEDRICH USC Wall Sleeve
  • Page 13 – ITEMS IN INSTALLATION HARDWARE; HOW TO INSTALL; Procedure
  • Page 14 – PROCEDURE; or; Wall; Install the new unit into the wall sleeve.
  • Page 15 – PROCEDURE B; If the depth of your existing wall sleeve is less; cut the baffles and the support blocks according
  • Page 16 – PROCEDURE B CONTINUED; Slide the baffle into slots of the support blocks.; • Air conditioners covered in this manual pose an
  • Page 18 – Parts; PROCEDURE C CONTINUED; strips and attach them as shown below in Fig.; Assemble trim as described in Step 6,
  • Page 19 – TROUBLESHOOTING GUIDE; OUTSIDE DIMENSIONS; ROOM AIR CONDITIONER
  • Page 20 – TROUBLESHOOTING GUIDE; Unit is running but cooling is ineffective
  • Page 21 – Fails to Start
  • Page 23 – ROOM AIR CONDITIONER VOLTAGE LIMITS
  • Page 24 – Voltage
  • Page 27 – REPLACEMENT PARTS LIST; A; QTY; LOCATION; DESCRIPTION
  • Page 28 – THE QUALITY LEADER IN CONDITIONING AIR; Printed in Korea
Loading the manual

Service Manual

CAUTION

-Before servicing the unit, read the "safety precautions" in this manual.
-Only for authorized service personnel.

Through-The-Wall

Air Conditioning

HEAT CONTROLLER, INC.

Model:

BG-

103A

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SERVICE MANUAL; SAFETY PRECAUTIONS; CONTENTS

—2— 1. PREFACE 1.1 SAFETY PRECAUTIONS ...............................21.2 INSULATION RESISTANCE TEST.................21.3 SPECIFICATIONS ..........................................31.4 FEATURES ..................................................... 4 1.5 CONTROL LOCATIONS ................................

Page 3 - STRUCTION; REMARK

—3— 1.3 SPECIFICATIONS 1.3.1 FOR BG-10 3A POWER SUPPLY COOLING CAPACITY (Btu/h) INPUT (W) RUNNING CURRENT (A) E.E.R (Btu/W.h) OPERATING INDOOR( ° C) TEMPERATURE OUTDOOR( ° C) REFRIGERANT (R-22) CHARGE (g) EVAPORATOR CONDENSER FAN, INDOOR FAN, OUTDOOR FAN SPEED (FAN/COOLING/HEATING) FAN MOTOR OPERATI...

Page 4 - • Designed for cooling only.; CONTROL LOCATIONS; • Built in adjustable THERMISTOR and THERMOSTAT.; • VENTILATION; PULL OPEN / PUSH CLOSE; TEMP; CAUTION

1.4 FEATURES • Designed for cooling only. • Powerful and quiet cooling.• Top-down chassis for the simple installation and service. 1.5 CONTROL LOCATIONS 1.5.1 COOLING ONLY MODEL• OPERATION • Side air-intake, side cooled-air discharge. • Built in adjustable THERMISTOR and THERMOSTAT. • Washable one-t...

Other Heat Controller Models