Heat Controller A-VCH18DC-1 - Manual

Heat Controller A-VCH18DC-1

Heat Controller A-VCH18DC-1 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
Page: / 25

Table of Contents:

  • Page 2 – Installation Manual; VMH SerieS; CONTENTS; improvement. The actual shape should prevail.; CAUTION
  • Page 3 – SAFETY PRECAUTIONS; of the power plug and main circuit for the model to be installed.; The seriousness is classified by the following indications.; This symbol indicates the possibility of death or serious injury.; The items to be followed are classified by the symbols:; water leakage, electrical shock fire.; may enter the room and damage the furniture.
  • Page 4 – NOMeNcLATUre; ceiling cassette
  • Page 5 – nit combination; Indoor unit combinations; Indoor unit combinations; Available indoor models:; High Wall Mount
  • Page 6 – This illustration is for explanation purposes only.; NOTE: Ceiling cassettes come with an; INSTALLATION INSTRUCTIONS; CAUTIONS; NOTE: Indoor units shown can be replaced with ceiling cassettes.
  • Page 7 – Installation Details; Wrench torque sheet for installation; is provided with all 12/18k indoor sections.
  • Page 8 – Read completely, then follow step by step.; Install the main body; INSTALLATION INSTRUCTIONS; Included Pans; Clearance
  • Page 9 – Accessories for mini-split high wall mount installation; Tools needed for installation:; Name of Accessories; Optional
  • Page 10 – Fit the Installation Plate; Do not install the drain hose as; Drainage
  • Page 11 – Connective pipe installation; Indoor unit
  • Page 12 – Indoor unit installation
  • Page 14 – New built houses and ceilings
  • Page 16 – Settlement of outdoor unit; Strong; Outdoor unit installation; O u t d o o r u n i t d i m e n s i o n; Outdoor Unit Installation; Outdoor installation precaution; is lengthwise along the wall or provide a suitable; Anchoring outdoor unit; Outdoor unit dimensions
  • Page 17 – Drain joint installation; Refrigerant pipe connection; Flare nut; REFRIGERANT PIPE CONNECTION
  • Page 18 – Tightening Connection; Caution; Outer diameter; Outer; Refrigerant Pipe Connection
  • Page 19 – ELECTRICAL WORK; Wiring connection; NOTE: Before performing any electrical; Connection Cable; Minimum norminal cross-sectional area; Screw
  • Page 20 – Ferrile Core Filter
  • Page 21 – Air Purging; Preparation; Capacity; 8k Dual Zone
  • Page 22 – When Using the Vacuum Pump; vacuum pump changes and a compound meter indicates 0; Caution in handling the packed valve
  • Page 23 – C and D are ends of indoor unit connection.; Electrical safety check; AIR PURGING; The illustration is for explanation; NOTE; and D on the machine may be slightly; Refrigerant Leak Check
  • Page 24 – Test running; electrical safety check.; TEST RUNNING; Testing the System
Loading the manual

Heat Controller, Inc. • 1900 Wellworth Ave. • Jackson, MI 49203 • (517)787-2100 • www.heatcontroller.com

INSTALLATION

MANUAL

Indoor Models:

B-VCH12FC-1

B-VCH18FC-1

B-VMH09FC-1

B-VMH12FC-1

B-VMH18FC-1

Version C

InverterFlex

Ductless Mini-Split Heat Pumps

High Wall and Ceiling Cassettes

Outdoor Models:

A-VCH18DC-1

A-VCH27TC-1

A-VMH36QC-1

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Installation Manual; VMH SerieS; CONTENTS; improvement. The actual shape should prevail.; CAUTION

2 Installation Manual VMH SerieS Heat Controller, Inc. 1 CONTENTS SAFETY PRECAUTIONS Warning ...........................................................................................................................................2 Caution .............................................................

Page 3 - SAFETY PRECAUTIONS; of the power plug and main circuit for the model to be installed.; The seriousness is classified by the following indications.; This symbol indicates the possibility of death or serious injury.; The items to be followed are classified by the symbols:; water leakage, electrical shock fire.; may enter the room and damage the furniture.

3 Heat Controller, Inc. VMH SerieS Installation Manual 2 SAFETY PRECAUTIONS WARNING Read the follow SAFETY PRECAUTIONS carefully before installation. Electrical work must be installed by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit for the model to be ...

Page 4 - NOMeNcLATUre; ceiling cassette

4 Installation Manual VMH SerieS Heat Controller, Inc. Outdoor Models: A - vMh18dc - 1 NOMeNcLATUre Outdoor Inverter Multi-Zone Mini-Split Heat Pump Nominal Capacity 18=18kBtu/H 27=27kBtu/H 36=36kBtu/H D=Dual Zone T-Tri-Zone Q-Quad Zone Indoor Models: B - vMh09Fc - 1 Indoor Inverter Heat Pump M=Mini...

Other Heat Controller Models

All Heat Controller Other