Heat Controller 7.5 - Manual
Heat Controller 7.5 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 3 – CAUTION; are not; Manifold sets need to range up
- Page 4 – FIGURE 1; FIGURE 2; ] Designates Metric Conversions
- Page 5 – FIGURE 3; FIGURE 4
- Page 6 – FIGURE 5; *RECOMMENDED DUCT DIMENSIONS ARE 26
- Page 10 – ELECTRICAL DATA - PCG
- Page 12 – To prevent transmission of; FIGURE 6
- Page 13 – If unit will not be put into service immediately,; FIGURE 8; CORNER WEIGHTS BY PERCENTAGE
- Page 15 – XI. ELECTRICAL WIRING; UNITS WITHOUT ELECTRIC HEAT -; WARNING
- Page 16 – THERMOSTAT; XII. INDOOR AIR FLOW DATA; Crankcase heaters are standard on 6 ton and single stage 7
- Page 18 – REPLACEMENT PARTS
- Page 19 – ig; IR
- Page 20 – AIRFLOW PERFORMANCE—RKNB- SERIES
- Page 24 – XIX. HEATER KIT CHARACTERISTICS
- Page 27 – XX. TROUBLE SHOOTING CHART; SYMPTOM
- Page 28 – WIRING DIAGRAM
- Page 29 – WIRING SCHEMATIC
- Page 32 – PCG SYSTEM CHARGE CHARTS; XXII. CHARGING CHARTS; SYSTEM CHARGE CHART - REFRIGERANT 410A
INSTALLATION INSTRUCTIONS
PACKAGE AIR CONDITIONERS FEATURING EARTH-FRIENDLY
R410A REFRIGERANT
PCG SERIES 6, 7.5, 8.5, 10 & 12.5 TON [21.1, 26.4, 29.9, 35.2 & 44 kW]
60 HZ MODELS
92-21916-45-00
[
] Designates Metric Conversions
THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALI-
FIED, LICENSED SERVICE PERSONNEL FOR PROPER INSTALLA-
T I O N , A D J U S T M E N T A N D O P E R A T I O N O F T H I S U N I T . R E A D
THESE INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING
INSTALLATION OR OPERATION. FAILURE TO FOLLOW THESE
INSTRUCTIONS MAY RESULT IN IMPROPER INSTALLATION,
ADJUSTMENT, SERVICE OR MAINTENANCE POSSIBLY RESULT-
ING IN FIRE, ELECTRICAL SHOCK, PROPERTY DAMAGE, PER-
SONAL INJURY OR DEATH.
WARNING
!
DO NOT DESTROY
PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE
FOR FUTURE REFERENCE.
Recognize this symbol as an indication of Important Safety Information!
!
e a r t h f r i e n d l y r e f r i g e r a n t
e a r
t
t h
r
y r
d l y
d l
y
e n
d
r i e
n
i
h f r
i
h
HEAT CONTROLLER
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
• R-410A refrigerant cylinders are pink. • R-410A, as with other HFC’s is only compatible with POE oils. • Vacuum pumps will not remove moisture from POE oil. • R-410A systems are to be charged with liquid refrigerants. Prior to March 1999, R-410A refrigerant cylinders had a diptube. These cylinders...
4 RETURN COVER SU PP LY * RE TU RN * SUPPLY COVER COMPRESSOR ACCESS FIGURE 1 UNIT DIMENSIONS FIGURE 2 UNIT DIMENSIONS ST-A1112-02-00 ST-A1112-01-00 40 3 ⁄ 16 ” [1020.7 mm] 3 13 ⁄ 16 ” [96.8 mm] 5” [127 mm] 11 11 ⁄ 16 ” [296.9 mm] 4 1 ⁄ 8 ” [104.8 mm] 6 5 ⁄ 8 ” [168.3 mm] 6 13 ⁄ 16 ” [173 mm] 58 3 ⁄ ...
5 FIGURE 3 UNIT DIMENSIONS A0737-03 CONDENSATE DRAIN 1” [25.4 mm] FNPT CONTROL/FILTER ACCESS ELECTRIC HEAT ACCESS BLOWER ACCESS CONTROL ENTRY POWER ENTRY COMPRESSOR ACCESS (BOTH SIDE SOME MODELS) GAUGE PORT CONNECTIONS 93.688” [2379.7 mm] 58.75” [1487.7 mm] 44” [1117.6 mm] 27.268” [692.6 mm] 33.715”...