Page 2 - Disclaimer
Disclaimer Hand Held Products, Inc. (“Hand Held Products“) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult Hand Held Products to determine whether any such changes have been made. T...
Page 3 - Statement of Agency Compliance; FCC Class B Compliance Statement
Statement of Agency Compliance The IT2020/IT5620 system meets or exceeds the requirements of all applicable standards organizations for safe operation. However, as with any electrical equipment, the best way to ensure safe operation is to operate them according to the agency guidelines that follow. ...
Page 4 - Canadian Compliance; CE Compliance
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following booklet helpful: “Something About Interference.” This is available at FCC local regional offices. Hand Held Products, Inc. is not responsible for...
Page 5 - Bluetooth Qualified Product
Hand Held Products shall not be liable for use of our product with equipment (i.e., power supplies, personal computers, etc.) that is not CE marked and does not comply with the Low Voltage Directive. Regulatory Approvals for Bluetooth Radio Devices RF devices are designed to comply with the most cur...
Page 6 - Solids and Water Protection
UL and cUL Statement UL listed UL1950 and CSA 22.2 No.950. cUL listed UL1950 and CSA 22.2 No 950. TÜV Statement TÜV or GS marked to EN60950 and EN60825-1. C-Tick Statement Conforms to AS/NZS 3548. C-Tick number: N10410. Mexico Patents Please refer to the IT5620 packaging for patent information. Soli...
Page 7 - Required Safety Labels
Page 9 - Chapter 1 - Getting Started; Resetting the Standard Product Default Settings:; Table of Contents
i Chapter 1 - Getting Started About This Manual ............................................................... 1-1Unpacking the System .......................................................... 1-2Models .................................................................................. 1-2Cordless ...
Page 10 - ii; Connecting the Base When Powered by Host; Chapter 2 - Terminal Interfaces
ii Basic Operation of the Cordless System ............................. 1-16 System Conditions ........................................................ 1-17Communication Between the Cordless Systemand the Host .................................................................. 1-18 Connecting the Bas...
Page 11 - iii
iii Wand Emulation .................................................................. 2-13 Wand Emulation Connection ........................................ 2-13Wand Emulation Transmission Rate ............................ 2-14Wand Emulation Polarity.............................................. 2-...
Page 12 - iv; Chapter 4 - Data Editing
iv Chapter 4 - Data Editing Prefix/Suffix Overview ......................................................... 4-1 To Add a Prefix or Suffix: ............................................. 4-2To Clear One or All Prefixes or Suffixes: ...................... 4-3To Add a Carriage Return Suffix to all Symb...
Page 15 - vii; Chapter 7 - Interface Keys; Resetting the Standard Product Default Settings: All; Chapter 10 - Serial Programming Commands
vii Code 49................................................................................ 6-36 Code 49 Message Length.............................................. 6-36 Chapter 7 - Interface Keys Keyboard Function Relationships ......................................... 7-1Supported Interface Keys ...
Page 16 - viii; Chapter 11 - Product Specifications
viii Resetting the Standard Product Default Settings: All Application Work Groups ................................................ 10-5 Menu Commands ................................................................ 10-6 Chapter 11 - Product Specifications IMAGETEAM 5620 Product Specifications .........
Page 17 - Getting Started; About This Manual
IMAGETEAM™ 2020/5620 System Manual 1 - 1 1 Getting Started The IMAGETEAM 5620 cordless scanning system consists of one IT2020-5A base and one IT5620 Cordless Linear Imager. Up to seven scanners may be linked to one base. The IT5620 marks a new performance level for hand held scanners. The IT5620 is ...
Page 18 - Unpacking the System
1 - 2 IMAGETEAM™ 2020/5620 System Manual • Connection of the Base to an Interface Unpacking the System After you open the shipping carton containing the product, take the following steps: • Check to make sure everything you ordered is present. • Save the shipping container for later storage or shipp...
Page 19 - Charging Information
IMAGETEAM™ 2020/5620 System Manual 1 - 3 Cordless System: Main Components About the Battery Use only the Li-ion battery packs provided by Hand Held Products. The use of any battery pack not sold by Hand Held Products will void your warranty and may result in damage to your unit. Power is supplied to...
Page 20 - Battery Recommendations; Proper Disposal of the Battery
1 - 4 IMAGETEAM™ 2020/5620 System Manual Battery Recommendations • Batteries are shipped approximately 30% to 60% charged and should be fully charged for maximum charge capacity. • The battery is a lithium ion cell and can be used without a full charge, as well as can be charged without fully discha...
Page 21 - Base Charge Mode
IMAGETEAM™ 2020/5620 System Manual 1 - 5 Base Charge Mode In order for the battery to be charged, there must be enough voltage for the circuitry to work. There are three conditions during which power can be supplied to the base: Condition 1: 9VDC power supply connected to the barrel connector Condit...
Page 22 - Linking Scanner to Base; Scanner Modes; Unlinking the Scanner
1 - 6 IMAGETEAM™ 2020/5620 System Manual Linking Scanner to Base When newly shipped or defaulted to factory settings, the base and scanner are not linked. Once the scanner is placed into the base, the software automatically links the scanner and the base. If the scanner and base have previously been...
Page 23 - Single Scanner Operation; Locked Link Mode - Single Scanner
IMAGETEAM™ 2020/5620 System Manual 1 - 7 Single Scanner Operation There are two link modes to accommodate different applications: Locked Link Mode and Open Link Mode. Scan the appropriate bar codes included in the Open Link and Locked Link Mode explanations that follow to switch from one mode to ano...
Page 24 - Changing Scanner Name - Serially
1 - 8 IMAGETEAM™ 2020/5620 System Manual Multiple Scanner Operation To put the scanner in multiple scanner mode, scan the bar code below. Once you scan this bar code, the scanner is unlinked from the base and must be placed into the base to re-link. Note: Multiple Scanner Operation Mode allows you t...
Page 25 - Changing Scanner Name - via Bar Codes
IMAGETEAM™ 2020/5620 System Manual 1 - 9 Changing Scanner Name - via Bar Codes If you wanted set up your scanners with names 0001-0007, you may scan the bar codes below. Scan the Reset bar code after each name change and wait for the scanner to re-link to the base before scanning the next bar code t...
Page 27 - Application Work Group Selection
IMAGETEAM™ 2020/5620 System Manual 1 - 11 Application Work Group Selection This programming selection allows you to assign an scanner to a work group by scanning the bar code below. You may then program the settings (e.g., beeper volume, prefix/suffix, data formatter) that your application requires....
Page 28 - Standard Product Default Settings: Current Application Group
1 - 12 IMAGETEAM™ 2020/5620 System Manual Resetting the Standard Product Default Settings:Current Application Work Group If you aren’t sure what programming options are in your scanner, or you’ve changed some options and want the standard product default settings restored, scan the Standard Product ...
Page 29 - Using the Scanner with Bluetooth Devices; Changing Bluetooth PIN Code; Duration
IMAGETEAM™ 2020/5620 System Manual 1 - 13 Using the Scanner with Bluetooth Devices The IT5620 scanner may be used either with the IT2020-5A base or with other Bluetooth devices. Scanning the Non-Base Bluetooth Connection bar code below allows the scanner to be used with other Bluetooth devices (e.g....
Page 30 - Alarm Sound Type; Data Accumulation Mode
1 - 14 IMAGETEAM™ 2020/5620 System Manual Note: If you are out of range when you scan a bar code, you will receive an error beep even if you do not have the alarm set. You receive the error beep since the data could not be communicated to the base or the host. Alarm Sound Type If you have set the ou...
Page 32 - Basic Operation of the Cordless System; Cordless Base
1 - 16 IMAGETEAM™ 2020/5620 System Manual Note: Charging only occurs with external power applied to the IT2020 or 12 volt Host power. Basic Operation of the Cordless System Cordless Base The cordless base provides the link between the cordless scanner and the host system. The base contains an interf...
Page 33 - Cordless Scanner; System Conditions; Linking Process
IMAGETEAM™ 2020/5620 System Manual 1 - 17 Cordless Scanner The cordless scanner enables fast and accurate bar code scanning using a non-contact linear scanner. The scanner is comprised of a linear scanner, a decode/control assembly, and an RF communication module. The scan engine performs the bar co...
Page 34 - Communication Between the Cordless System and the Host
1 - 18 IMAGETEAM™ 2020/5620 System Manual Communication Between the Cordless System and the Host The cordless scanner provides immediate feedback in the form of a “good read” indication (a green LED on the scanner and an audible beep) after a bar code is scanned correctly and the base has acknowledg...
Page 36 - Plug and Play
1 - 20 IMAGETEAM™ 2020/5620 System Manual Reading Techniques The scanner has a view finder that projects a bright red aiming beam that corresponds to its horizontal field of view. The aiming line should be centered horizontally over the bar code; it will not read if the aiming line is in any other d...
Page 37 - Keyboard Wedge Connection
IMAGETEAM™ 2020/5620 System Manual 1 - 21 Note: After you scan one of the codes, power cycle the host terminal to have the interface in effect. Keyboard Wedge Connection If you want your system programmed for an IBM PC AT and compatibles keyboard wedge interface with a USA keyboard, scan the bar cod...
Page 38 - Wand Emulation Plug & Play; Wand Emulation Plug & Play Code 39 Format
1 - 22 IMAGETEAM™ 2020/5620 System Manual Wand Emulation Plug & Play In Wand Emulation mode, the scanner decodes the bar code then sends data in the same format as a wand scanner. The Code 39 Format converts all symbologies to Code 39. The Same Code Format transmits UPC, EAN, Code 128 and Interl...
Page 40 - Connecting the Base with USB
1 - 24 IMAGETEAM™ 2020/5620 System Manual Connecting the Base with USB A base can be connected to the USB port of a computer. 1. Connect the appropriate interface cable to the base and to the computer. 2. Program the base for the USB interface by scanning the appropriate programming bar code. 3. Ver...
Page 43 - Connecting the Base with Serial Wedge
IMAGETEAM™ 2020/5620 System Manual 1 - 27 Connecting the Base with Serial Wedge The IT2020 uses TTL signal levels to wedge into an RS-232 serial network. Use only IT2020-5A serial wedge cables to prevent damage to the base. Refer to Connecting the Base with RS-232 Serial Port on page 2-7 to set the ...
Page 45 - Terminal Interfaces
IMAGETEAM™ 2020/5620 System Manual 2 - 1 2 Terminal Interfaces Terminal ID If your interface is not a standard PC AT, refer to "Supported Terminals" on page 2-2 through page 2-3 , and locate the Terminal ID number for your PC. Scan the Terminal ID bar code below, then scan the numeric bar co...
Page 46 - Supported Terminals
2 - 2 IMAGETEAM™ 2020/5620 System Manual Supported Terminals Terminal Model(s) Terminal ID DEC VT510, 520, 525 (PC style) 005 DEC VT510, 520, 525 (DEC style LK411) 104 Esprit 200, 400 005 Heath Zenith PC, AT 003* HP Vectra 003* IBM XT 001 IBM PS/2 25, 30, 77DX2 002 IBM AT, PS/2 30–286, 50, 55SX, 60,...
Page 48 - Keyboard Country
2 - 4 IMAGETEAM™ 2020/5620 System Manual Keyboard Country Scan the appropriate country code below to program the keyboard for your country. As a general rule, the following characters are supported, but need special care for countries other than the United States:@ | $ # { } [ ] = / ‘ \ < > ~ ...
Page 49 - Keyboard Style; Regular
IMAGETEAM™ 2020/5620 System Manual 2 - 5 Please refer to the Hand Held Products website ( www.handheld.com ) for complete keyboard country support information and applicable interfaces. If you need to program a keyboard for a country other than one listed above, scan the Program Keyboard Country bar...
Page 50 - Emulate External Keyboard; Keyboard Modifiers
2 - 6 IMAGETEAM™ 2020/5620 System Manual Emulate External Keyboard should be scanned if you do not have an external keyboard (IBM AT or equivalent). Note: After scanning the Emulate External Keyboard bar code, you must power cycle your computer. Keyboard Modifiers This modifies special keyboard feat...
Page 51 - Automatic Direct Connect Mode:
IMAGETEAM™ 2020/5620 System Manual 2 - 7 Automatic Direct Connect Mode: This selection can be used if you have an IBM AT style terminal and the system is dropping characters. Default = Off Connecting the Base with RS-232 Serial Port 1. Turn off power to the terminal/computer. 2. Connect the appropri...
Page 53 - Data Bits; Stop Bits; Parity
IMAGETEAM™ 2020/5620 System Manual 2 - 9 RS-232 Word Length: Data Bits, Stop Bits, and Parity Data Bits sets the word length at 7 or 8 bits of data per character. If an application requires only ASCII Hex characters 0 through 7F decimal (text, digits, and punctuation), select 7 data bits. For applic...
Page 54 - Off; On; Host ACK Selection
2 - 10 IMAGETEAM™ 2020/5620 System Manual RS-232 Handshaking RS-232 Handshaking allows control of data transmission from the Imager using software commands from the host device. CTS/RTS operates in mode 2. When this feature is turned Off , no data flow control is used. When Data Flow Control is turn...
Page 55 - Host ACK Enable
IMAGETEAM™ 2020/5620 System Manual 2 - 11 The commands to which the scanner responds are listed on page 2-12. The <ESC> is a 1B in hex. A typical command string is y <ESC> x, where “y” is the application work group number, “<ESC> x” is the escape command, and the comma is the termi...
Page 57 - Wand Emulation; Wand Emulation Connection; Code 39 Format
IMAGETEAM™ 2020/5620 System Manual 2 - 13 Wand Emulation Wand Emulation Connection The Wand Emulation Connection bar codes should be used if you want to change the terminal ID only , without changing any other imager settings. We recommend using Wand Emulation Plug & Play bar codes to program yo...
Page 59 - Wand Emulation Idle; Wand Emulation Data Block Size
IMAGETEAM™ 2020/5620 System Manual 2 - 15 Wand Emulation Idle The idle describes the state of the scanner when no data is being transmitted. When in Wand Emulation mode, you must set the scanner’s idle state to match the idle state for the device to which the scanner is connected. Default = Idle Hig...
Page 60 - Wand Emulation Overall Checksum
2 - 16 IMAGETEAM™ 2020/5620 System Manual Wand Emulation Overall Checksum When this option is turned on, a computed check character is added at the end of the entire message. The check character is the character which when Exclusive-OR’d with every preceding character of the message yields a result ...
Page 61 - Output; Scanner Functions; Good Read Indicators; Beeper – Good Read
IMAGETEAM™ 2020/5620 System Manual 3 - 1 3 Output Scanner Functions Good Read Indicators Beeper – Good Read The beeper may be programmed On or Off in response to a good read. Turning this option off, only turns off the beeper response to a good read indication. All error and menu beeps are still aud...
Page 63 - Number of Beeps – Good Read; Good Read Delay; User-Specified Good Read Delay
IMAGETEAM™ 2020/5620 System Manual 3 - 3 Number of Beeps – Good Read The number of beeps of a good read can be programmed from 1 - 9. The same number of beeps will be applied to the beeper and LED in response to a good read. For example, if you program this option to have five beeps, there will be f...
Page 64 - Scanner Trigger Modes; Scanner Power Time-Out Timer
3 - 4 IMAGETEAM™ 2020/5620 System Manual Scanner Trigger Modes Manual/Serial Trigger, Low Power You can activate the scanner either by pressing the trigger, or using a serial trigger command (see "Trigger Commands" on page 10-4). When in manual trigger mode, the scanner scans until a bar cod...
Page 66 - Reread Delay
3 - 6 IMAGETEAM™ 2020/5620 System Manual Hands Free Time-Out The Automatic Trigger and Presentation Modes are referred to as “hands free” modes. If the imager’s trigger is pulled when using a hands free mode, the imager changes to manual trigger mode. You can set the time the imager should remain in...
Page 67 - Centering Window
IMAGETEAM™ 2020/5620 System Manual 3 - 7 Centering Window Use the centering feature to narrow the scanner’s field of view so the scanner reads only the bar code you want. When centering is turned on, the scanner only reads codes that intersect or are contained within the centering window you set up....
Page 68 - Output Sequence Overview; Default Sequence; Enter Sequence
3 - 8 IMAGETEAM™ 2020/5620 System Manual Example: If you have two bar codes next to one another and the centering window is set to 40% left edge and 60% right edge, only the bar code that intersects that window will be decoded. Output Sequence Overview Require Output Sequence When turned off, the ba...
Page 69 - F F; Discard; Output Sequence Editor; Required
IMAGETEAM™ 2020/5620 System Manual 3 - 9 3. Length Specify what length (up to 9999 characters) of data output will be acceptable for this symbology. Scan the four digit data length from the Programming Chart inside the back cover of this manual. (Note: 50 characters is entered as 0050. 9999 is a uni...
Page 70 - Output Sequence Example
3 - 10 IMAGETEAM™ 2020/5620 System Manual Note: This selection is unavailable when the Multiple Symbols Selection is turned on. Output Sequence Example In this example, you are scanning Code 93, Code 128, and Code 39 bar codes, but you want the scanner to output Code 39 1st, Code 128 2nd, and Code 9...
Page 72 - No Read; Video Reverse
3 - 12 IMAGETEAM™ 2020/5620 System Manual Multiple Symbols When this programming selection is turned On , it allows you to read multiple symbols with a single pull of the scanner’s trigger. If you press and hold the trigger, aiming the scanner at a series of symbols, it reads unique symbols once, be...
Page 73 - Data Editing; Prefix/Suffix Overview; Points to Keep In Mind
IMAGETEAM™ 2020/5620 System Manual 4 - 1 4 Data Editing Prefix/Suffix Overview When a bar code is scanned, additional information is sent to the host computer along with the bar code data. This group of bar code data and additional, user-defined data is called a “message string.” The selections in t...
Page 74 - To Add a Prefix or Suffix:; Example: Add a Suffix to a specific symbology
4 - 2 IMAGETEAM™ 2020/5620 System Manual To Add a Prefix or Suffix: Step 1. Scan the Add Prefix or Add Suffix symbol ( page 4-3 ). Step 2. Determine the 2 digit Hex value from the Symbology Chart (included in the Appendix A ) for the symbology to which you want to apply the prefix or suffix. For exa...
Page 75 - To Clear One or All Prefixes or Suffixes:; To Add a Carriage Return Suffix to all Symbologies
IMAGETEAM™ 2020/5620 System Manual 4 - 3 To Clear One or All Prefixes or Suffixes: You can clear a single prefix or suffix, or clear all prefixes/suffixes for a symbology. When you Clear One Prefix (Suffix), the specific character you select is deleted from the symbology you want. When you Clear All...
Page 76 - Intercharacter, Interfunction, and Intermessage Delays
4 - 4 IMAGETEAM™ 2020/5620 System Manual Suffix Selections Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Charts of these function codes are provided in Supported Interface Keys ...
Page 77 - Intercharacter Delay; User Specified Intercharacter Delay
IMAGETEAM™ 2020/5620 System Manual 4 - 5 Intercharacter Delay An intercharacter delay of up to 495 milliseconds may be placed between the transmission of each character of scanned data. Scan the Intercharacter Delay bar code below, then scan the number of milliseconds and the SAVE bar code using the...
Page 78 - Interfunction Delay; Intermessage Delay
4 - 6 IMAGETEAM™ 2020/5620 System Manual Interfunction Delay An interfunction delay of up to 495 milliseconds may be placed between the transmission of each segment of the message string. Scan the Interfunction Delay bar code below, then scan the number of milliseconds and the SAVE bar code using th...
Page 79 - Data Formatting; Data Format Editor Introduction; To Add a Data Format
IMAGETEAM™ 2020/5620 System Manual 5 - 1 5 Data Formatting Data Format Editor Introduction You may use the Data Format Editor to change the scanner’s output. For example, you can use the Data Format Editor to insert characters at certain points in bar code data as it is scanned. The selections in th...
Page 80 - Data Format Editor Commands
5 - 2 IMAGETEAM™ 2020/5620 System Manual Note: The wildcard for all terminal types is 099. Step 4. Code I.D. In the Appendix A , find the symbology to which you want to apply the data format. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart inside the...
Page 81 - Move Commands; Miscellaneous Commands
IMAGETEAM™ 2020/5620 System Manual 5 - 3 hex values for ASCII codes, see ASCII Conversion Chart (Code Page 1252) on page A-2.) F4 Send “xx” character “nn” times (Insert) leaving cursor in current cursor posi- tion. Syntax = F4xxnn (xx stands for the hex value for an ASCII code, see ASCII Conversion ...
Page 82 - Data Format Editor
5 - 4 IMAGETEAM™ 2020/5620 System Manual E4 Replaces up to 15 characters in the data string with user specified charac- ters. Replacement continues until the E5 command is encountered. Syn- tax = E4nnxx 1 xx 2 yy 1 yy 2 ...zz 1 zz 2 where nn is the total count of both characters to be replaced plus ...
Page 85 - Symbologies; Introduction; All Symbologies On
IMAGETEAM™ 2020/5620 System Manual 6 - 1 6 Symbologies Introduction This programming section contains the following menu selections. Refer to Chapter 10 for settings and defaults. All Symbologies If you want to decode all the symbologies allowable for your scanner, scan the All Symbologies On code. ...
Page 86 - Message Length
6 - 2 IMAGETEAM™ 2020/5620 System Manual Message Length You are able to set the valid reading length of some of the bar code symbologies. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will issue an error beep. You may wish to set the same value for mi...
Page 87 - Codabar Start / Stop Characters; Codabar Check Character; No Check Character
IMAGETEAM™ 2020/5620 System Manual 6 - 3 Codabar <Default All Codabar Settings> Codabar Codabar Start / Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit . Codab...
Page 88 - Codabar Concatenation
6 - 4 IMAGETEAM™ 2020/5620 System Manual When Check Character is set to Validate, but Don’t Transmit , the unit will only read Codabar bar codes printed with a check character, but will not transmit the check character with the scanned data. Codabar Concatenation Codabar supports symbol concatenatio...
Page 89 - Codabar Message Length; Code 39 Start / Stop Characters
IMAGETEAM™ 2020/5620 System Manual 6 - 5 Codabar Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 2-60. Minimum Default = 4, Maximum Default = 60. Code 39 < Default All Code 39 Setti...
Page 90 - Code 39 Check Character; Code 39 Message Length
6 - 6 IMAGETEAM™ 2020/5620 System Manual Code 39, continued Code 39 Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character. When Check Character is set to Validate, but Don’t Transmit , the unit only reads Code 39 bar codes p...
Page 91 - Code 39 Append
IMAGETEAM™ 2020/5620 System Manual 6 - 7 Code 39, continued Code 39 Append This function allows the scanner to append the data from several Code 39 bar codes together before transmitting them to the host computer. When this function is enabled, the scanner stores those Code 39 bar codes that start w...
Page 92 - Full ASCII
6 - 8 IMAGETEAM™ 2020/5620 System Manual Note: Trioptic Code must be turned off to scan Code 32 Pharmaceutical codes. Full ASCII If Full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single character. For example: $V will be decoded as...
Page 93 - Code 39 Code Page; < Default All Interleaved 2 of 5 Settings >; Interleaved 2 of 5; Check Digit
IMAGETEAM™ 2020/5620 System Manual 6 - 9 Code 39 Code Page Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the one the h...
Page 94 - Interleaved 2 of 5 Message Length
6 - 10 IMAGETEAM™ 2020/5620 System Manual When Check Digit is set to Validate, but Don’t Transmit , the unit only reads Interleaved 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data. When Check Digit is set to Validate and Transmit , the scanner...
Page 95 - Code 93 Message Length; Code 93 Code Page
IMAGETEAM™ 2020/5620 System Manual 6 - 11 Code 93 < Default All Code 93 Settings > Code 93 Code 93 Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Maxi...
Page 96 - Code 2 of 5 Message Length; IATA Code 2 of 5
6 - 12 IMAGETEAM™ 2020/5620 System Manual Code 2 of 5 <Default All Code 2 of 5 Settings> Code 2 of 5 Code 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 1-48. Minimum Def...
Page 97 - IATA Code 2 of 5, continued; IATA Code 2 of 5 Message Length
IMAGETEAM™ 2020/5620 System Manual 6 - 13 IATA Code 2 of 5, continued IATA Code 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 1-48. Minimum Default = 4, Maximum Default = 48. ...
Page 98 - Matrix 2 of 5 Message Length; Check Digits Required
6 - 14 IMAGETEAM™ 2020/5620 System Manual Matrix 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80. Code 11 <Default All Code 11...
Page 99 - Code 11 Message Length
IMAGETEAM™ 2020/5620 System Manual 6 - 15 Code 11, continued Code 11 Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80. Code 128 <Defau...
Page 101 - Code 128 Function Code Transmit; Telepen; Telepen Output
IMAGETEAM™ 2020/5620 System Manual 6 - 17 Code 128 Function Code Transmit By default, Code 128 function codes are not transmitted with Code 128 bar code data. However, if you wish to transmit Code 128 function codes with the bar code data, scan the Function Codes On bar code, below. Telepen <Defa...
Page 102 - Telepen Message Length; UPC A Check Digit
6 - 18 IMAGETEAM™ 2020/5620 System Manual Telepen Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 1-60. Minimum Default = 1, Maximum Default = 60. UPC A <Default All UPC A Settings&...
Page 103 - UPC A Addenda Required
IMAGETEAM™ 2020/5620 System Manual 6 - 19 UPC A Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. Default = On. UPC A Addenda This selection adds 2 or 5 digits to the end ...
Page 104 - UPC A Addenda Separator; UPC E
6 - 20 IMAGETEAM™ 2020/5620 System Manual UPC A Addenda Separator When this feature is on, there is a space between the data from the bar code and the data from the addenda. When turned off, there is no space. Default = On. UPC-A/EAN-13 with Extended Coupon Code Use the following codes to enable or ...
Page 105 - UPC E0 and UPC E1; UPC E0 and UPC E1 Expand; UPC E0 and UPC E1 Addenda Required
IMAGETEAM™ 2020/5620 System Manual 6 - 21 UPC E0 and UPC E1 Most U.P.C. bar codes lead with the 0 number system. For these codes, use the UPC E0 selection. If you need to read codes that lead with the 1 number system, use the UPC E1 selection. Default = On (UPC E0) and Off (UPC E1). UPC E0 and UPC E...
Page 107 - UPC E0 Addenda; EAN/JAN 13 Check Digit
IMAGETEAM™ 2020/5620 System Manual 6 - 23 UPC E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC E data. Default = Off for both 2 Digit and 5 Digit Addenda. EAN/JAN 13 <Default All EAN/JAN Settings> EAN/JAN 13 EAN/JAN 13 Check Digit This selection allows you to specify ...
Page 108 - EAN/JAN 13 Addenda Required
6 - 24 IMAGETEAM™ 2020/5620 System Manual EAN/JAN 13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN 13 data. Default = Off for both 2 Digit and 5 Digit Addenda. EAN/JAN 13 Addenda Required When Addenda Required is set to on, the scanner will only read EAN/JAN 13 bar code...
Page 109 - ISBN Translate
IMAGETEAM™ 2020/5620 System Manual 6 - 25 Note: If you want to enable or disable EAN13 with Extended Coupon Code, refer to UPC-A/EAN-13 with Extended Coupon Code on page 6-20. ISBN Translate This selection causes EAN-13 Bookland symbols to be translated into their equivalent ISBN number format. Defa...
Page 110 - EAN/JAN 8 Addenda Required
6 - 26 IMAGETEAM™ 2020/5620 System Manual EAN/JAN 8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN 8 data. Default = Off for both 2 Digit and 5 Digit Addenda. EAN/JAN 8 Addenda Required When Addenda Required is set to on, the scanner will only read EAN/JAN 8 bar codes th...
Page 111 - MSI Check Character; Validate and Transmit
IMAGETEAM™ 2020/5620 System Manual 6 - 27 MSI <Default All MSI Settings> MSI MSI Check Character Different types of check characters are used with MSI bar codes. You can program the scanner to read MSI bar codes with Type 10 check characters. Default = Validate Type 10, but Don’t Transmit. Whe...
Page 112 - MSI Message Length; Plessey Code; Plessey Message Length
6 - 28 IMAGETEAM™ 2020/5620 System Manual MSI Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 4-48. Minimum Default = 4, Maximum Default = 48. Plessey Code <Default All Plessey Code...
Page 114 - RSS Expanded Message Length; EAN
6 - 30 IMAGETEAM™ 2020/5620 System Manual RSS Expanded < Default All RSS Expanded Settings > RSS Expanded RSS Expanded Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 4-74. Minim...
Page 115 - China Post Code
IMAGETEAM™ 2020/5620 System Manual 6 - 31 Identifier will be reported as “]C1”. If RSS Emulation is selected, the AIM Symbology Identifier will be reported as “]e0.” Any application that accepts EAN•UCC data can be simplified since it only needs to recognize one data carrier type. Default = EAN•UCC ...
Page 116 - Korea Post Message Length; PosiCode
6 - 32 IMAGETEAM™ 2020/5620 System Manual Korea Post Code <Default All Korea Post Code Settings> Korea Post Code Korea Post Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 2-80. ...
Page 117 - PosiCode A and B; PosiCode Message Length
IMAGETEAM™ 2020/5620 System Manual 6 - 33 PosiCode A and B You have to have PosiCode A and B on to read any of the PosiCode symbologies. PosiCode Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum ...
Page 118 - Codablock F Message Length
6 - 34 IMAGETEAM™ 2020/5620 System Manual Trioptic Code Trioptic Code is used for labeling magnetic storage media. Note: If you are going to scan Code 32 Pharmaceutical codes, Trioptic Code must be off. Codablock F <Default All Codablock F Settings> Codablock F Codablock F Message Length Scan ...
Page 119 - Code 16K Message Length
IMAGETEAM™ 2020/5620 System Manual 6 - 35 Code 16K <Default All Code 16K Settings> Code 16K Code 16K Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 0-160. Minimum Default = 1, M...
Page 120 - Code 49 Message Length
6 - 36 IMAGETEAM™ 2020/5620 System Manual Code 49 Code 49 Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 1-81. Minimum Default = 1, Maximum Default = 81. * On Off Minimum Message Leng...
Page 121 - Interface Keys; Keyboard Function Relationships
IMAGETEAM™ 2020/5620 System Manual 7 - 1 7 Interface Keys Keyboard Function Relationships The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+ relationships apply to all terminals that can be used with the scanner. Refer to page 2-6 enable Control + ASCII mode. Function Code...
Page 127 - Utilities; To Add a Test Code I.D. Prefix to All Symbologies; Reset Scanner
IMAGETEAM™ 2020/5620 System Manual 8 - 1 8 Utilities To Add a Test Code I.D. Prefix to All Symbologies This selection allows you to turn on transmission of a Code I.D. before the decoded symbology. (See the Symbology Chart, included in the Appendix A , page A-1) for the single character code that id...
Page 129 - Temporary Visual Menu 2003 Configuration
IMAGETEAM™ 2020/5620 System Manual 8 - 3 Note: Scanning this bar code also causes both the scanner and the base to perform a reset and become unlinked. Refer to "Scanner Modes" on page 1-6 for additional information. Resetting the Standard Product Default Settings: AllApplication Work Groups...
Page 131 - Visual Menu 2003 Introduction; Visual Menu 2003 Operations; Installing Visual Menu 2003 from the Web
IMAGETEAM™ 2020/5620 System Manual 9 - 1 9 Visual Menu 2003 Visual Menu 2003 Introduction Visual Menu 2003 provides the ability to configure a Hand Held Products scanning device by connecting the scanner to the com port of a PC. Visual Menu 2003 allows you to download updates to a scanner’s firmware...
Page 133 - Serial Programming Commands; Conventions; Menu Command Syntax
IMAGETEAM™ 2020/5620 System Manual 10 - 1 10 Serial Programming Commands The serial programming commands can be used in place of the programming bar codes. Both the serial commands and the programming bar codes will program the IT2020-5. For complete descriptions and examples of each serial programm...
Page 134 - Query Commands
10 - 2 IMAGETEAM™ 2020/5620 System Manual Data The new value for a menu setting, identified by the Tag and Sub-Tag. Storage A single character that specifies the storage table to which the command is applied. An exclamation point ( ! ) performs the com- mand’s operation on the device’s volatile menu...
Page 135 - Concatenation of Multiple Commands; Responses; Examples of Query Commands
IMAGETEAM™ 2020/5620 System Manual 10 - 3 Concatenation of Multiple Commands Multiple commands can be issued within one Prefix/Storage sequence. Only the Tag, SubTag, and Data fields must be repeated for each command in the sequence. If additional commands are to be applied to the same Tag, then the...
Page 136 - Trigger Commands
10 - 4 IMAGETEAM™ 2020/5620 System Manual Example #4: What are the device’s settings for all Codabar selections? Enter: cbr?. Response: CBRENA1[ACK],SSX0[ACK],CK20[ACK],CCT1[ACK],MIN2[ACK],MAX60[ACK],DFT[ACK]. This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or o...
Page 141 - Output Selections
IMAGETEAM™ 2020/5620 System Manual 10 - 9 Wand Emulation Transmis-sion Rate 10 WNDSPD0 2-14 *25 WNDSPD1 2-14 40 WNDSPD2 2-14 80 WNDSPD3 2-14 120 WNDSPD4 2-14 150 WNDSPD5 2-14 200 WNDSPD6 2-14 Wand Emulation Polarity *Black High WNDPOL0 2-14 White High WNDPOL1 2-14 Wand Emulation Idle Idle Low WNDIDL...
Page 143 - Prefix/Suffix Selections
IMAGETEAM™ 2020/5620 System Manual 10 - 11 Centering Centering On DECWIN1 3-7 *Centering Off DECWIN0 3-7 Left of Centering Window *40 DECLFT### 3-7 Right of Centering Window *60 DECRGT### 3-7 Output Sequence Editor Enter Sequence SEQBLK 3-9 Default Sequence SEQDFT 3-9 Require Output Sequence Require...
Page 153 - IMAGETEAM 5620 Product Specifications
IMAGETEAM™ 2020/5620 System Manual 11 - 1 11 Product Specifications IMAGETEAM 5620 Product Specifications Parameter Specification Dimensions (Typical): Height 6.2 inches (15.7 cm) Length 5.3 inches (13.5 cm) Width 3.2 inches (8.1 cm) Weight (with battery) 9.2 ounces (260 g) Light Source 630 nM visib...
Page 154 - IMAGETEAM 2020 Product Specifications
11 - 2 IMAGETEAM™ 2020/5620 System Manual IMAGETEAM 2020 Product Specifications Parameter Specification Dimensions (Typical): Height 3.1 inches (7.9 cm) Length 5.6 inches (14.2 cm) Width 4.3 inches (10.9 cm) Weight 8.8 ounces (250 g) Voltage: DC Barrel 8.5 to 9.5 volts Host Port 4.5-14 volts Current...
Page 155 - IMAGETEAM 5620 Depth of Field
IMAGETEAM™ 2020/5620 System Manual 11 - 3 IMAGETEAM 5620 Depth of Field Minimum Bar Width Maximum Near Field Minimum Far Field (no ambient lighting) 13 mil 100% UPC 1 in (2.5 cm) 24 in (61 cm) 7.5 mil Code 39 4 in (10 cm) 14 in (36 cm) 10 mil Code 39 2 in (5 cm) 18 in (46 cm) 13 mil Code 39 1 in (2....
Page 156 - Standard Cable Pinouts; Keyboard Wedge
11 - 4 IMAGETEAM™ 2020/5620 System Manual Standard Cable Pinouts Keyboard Wedge 10 Pin RJ41 Modular Plug connects to the base 1 2 C ord shield 3 T ied to supply power 4 S upply ground 5 T erminal clock 6 T erminal data 7 S upply power input (Refer to tables on page 11-2 .) 8 K eyboard data 9 K eyboa...
Page 158 - Serial Output
11 - 6 IMAGETEAM™ 2020/5620 System Manual Standard Cable Pinouts Serial Output 10 Pin RJ41 Modular Plug connects to the base 1 2 C ord shield 3 P rog 1 (Tied to supply power for primary cable) 4 S upply ground 5 R eceive data - Serial data to scanner 6 T ransmit data - Serial data from scanner 7 S u...
Page 159 - USB
IMAGETEAM™ 2020/5620 System Manual 11 - 7 Standard Cable Pinouts USB 10 Pin Modular Plug connects to the base 1 2 D ata + 3 T ied to supply power 4 S upply ground 5 6 7 5 volt supply power input 8 9 10 Data -
Page 161 - Maintenance; Cleaning the Scanner’s Window; Inspecting Cords and Connectors; Do not submerge the imager in water. The scanner’s
IMAGETEAM™ 2020/5620 System Manual 12 - 1 12 Maintenance Maintenance Repairs and/or upgrades are not to be performed on this product. These services are to be performed only by an authorized service center. See "Customer Support" on page 13-1 for further information. Cleaning the Scanner’s W...
Page 162 - Replacing the IT2020 Interface Cable:; Troubleshooting Base; End Cap
12 - 2 IMAGETEAM™ 2020/5620 System Manual Replacing the IT2020 Interface Cable: 1. Turn the power to the host system OFF. 2. Disconnect the base’s cable from the terminal or computer. 3. Turn the base upside down. 4. Pull the connector out while maintaining pressure on the connector release clip. 5....
Page 163 - Troubleshooting Scanner
IMAGETEAM™ 2020/5620 System Manual 12 - 3 If the green LED isn’t illuminated, check that: • The scanner is correctly placed in the base. • There is external power or 12 volt host power. • Charge mode is turned on. ( See "Base Charge Mode" on page 1-5 ) • The battery is not bad or deeply disc...
Page 164 - Troubleshooting the Cordless System
12 - 4 IMAGETEAM™ 2020/5620 System Manual 1. Scan the sample bar codes in the back of this manual. If the scanner reads the sample bar codes, check that your bar code is readable.Verify that your bar code symbology is enabled (see Chapter 6 ). 2. If the scanner still can’t read the sample bar codes,...
Page 165 - Customer Support; Product Service and Repair
IMAGETEAM™ 2020/5620 System Manual 13 - 1 13 Customer Support Product Service and Repair Hand Held Products provides service for all its products through service centers throughout the world. To obtain warranty or non-warranty service, return the unit to Hand Held Products (postage paid) with a copy...
Page 166 - Online Product Service and Repair Assistance; Technical Assistance; Online Technical Assistance; Limited Warranty
13 - 2 IMAGETEAM™ 2020/5620 System Manual Online Product Service and Repair Assistance You can also access product service and repair assistance online at www.handheld.com . Technical Assistance If you need assistance installing or troubleshooting your scanner, please call your Distributor or the ne...
Page 169 - FrCovrName-1 User’s Guide; Symbology Chart
FrCovrName-1 User’s Guide A - 1 Appendix A Symbology Chart Note: “m” represents the AIM modifier character. Refer to International Technical Specification, Symbology Identifiers, for AIM modifier character details. Note: Prefix / Suffix entries for specific symbologies override the universal (All Sy...
Page 170 - ASCII Conversion Chart (Code Page 1252
A - 2 FrCovrName-1 User’s Guide ASCII Conversion Chart (Code Page 1252 ) Note: This table applies to U.S. style keyboards. Certain characters may differ depending on your Country Code/PC regional settings. Dec Hex Char Dec Hex Char Dec Hex Char Dec Hex Char 0 00 NUL 160 20 224 40 @ 288 60 ‘ 1 01 SOH...
Page 172 - Code Page Mapping of Printed Bar Codes
A - 4 FrCovrName-1 User’s Guide Code Page Mapping of Printed Bar Codes Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from t...
Page 174 - Sample Symbols
Sample Symbols UPC A 0 123456 7890 Interleaved 2 of 5 Code 128 EAN 13 1234567890 Code 128 9 780330 290951 654 EAN 8 3210 5 456123 8 0 UPC-E