- Page 2 – Indoor unit; Removing of indoor unit body; Model; Pitch downward for drainage
- Page 3 – Installation of Outdoor Unit; Connecting the indoor/outdoor electric Cable; Note; When connecting the cable after installing the indoor unit; Cutting and Flaring Work of Piping; CAUTION; power; Wire with ground 12AWG
- Page 4 – On Drainage; Fix the cable with a clamp.; Connection; Attaching Drain-Elbow
Drawing for the installation of indoor and outdoor units
Necessary Tools for Installation
Torque wrench
(17mm,22mm,26mm)
Nipper
Reamer
Hacksaw
Pipe cutter
Gas leakage detector or
soap-and-water solution
Hole core drill
Flaring tool
Spanner wrench(17,19 and 26mm)
Knife
Measuring tape
Selection of Installation Place
Power Source
Preparation
The above picture is for reference only. Your product may look different.
Read this manual before installation
Explain the operation of the unit to the user according to this manual
NO.0010564641
Installation Manual of Room Air Conditioner
Optional parts for piping
Non-adhesive tape
Adhesive tape
Saddle (L.S) with screws
Connecting electric cable
for indoor and outdoor
Drain hose
Insulating material
Piping hole cover
Floor xing dimensions of the outdoor unit
Fixing of outdoor unit
Fix the unit to concrete or block with bolts
(2/5 in.) securely.
When tting the unit to wall surface, roof or
rooftop, x the unit securely in consideration
of earthquake and strong wind.
If vibration may affect the house, x the unit
by attaching a vibration-proof mat.
The models use HFC free refrigerant R410A
A
F
C
E
D
G
B
X
Y
X
Z
Dimensions(mm/inches)
Model
x
y
z
583
319.5
HSU218VHG-W
2HUM18HC03/R2(DB)
Hammer
Place where the distance of more than 3 ft from televisions, radios, wireless apparatuses
and uorescent lamps 3 feet or approximately.
In the case of xing the remote controller on a wall, place where the indoor unit can
receive signals when the uorescent lamps in the room are in use.
A distance marked
is available as illustrated in the below gure.
Indoor Unit - Select a location that is
Outdoor Unit - Select a location that is
Robust not causing vibration, where the unit can be supported satisfactorily.
Not affected by heat or steam generated in the vicinity, and where the inlet and outlet of
the unit are not disturbed.
Possible to drain easily, and where piping can be connected with the outdoor unit.
Where conditioned air can be spread in a room evenly.
tilated.
Strong enough base to bear the unit, where vibration and noise are not increased.
That is easily accessible for maintenance or service.
(Unit:mm / inch)
(4 1/2)
113.5
(23)
(12 5/8)
All wiring to the unit must be in accordance with the National Electric code
and local ordinances.
The marks from
to
in the gure are the
Part Numbers.
The distance between
the indoor unit and the
oor should be more
than 6 ft.
more than 10cm
more than 15 cm
more than 10cm
more than 20cm
more than 15cm
more than 60cm
A
Indoor unit A
Indoor unit B
F
C
G
Arrangement of piping
directions
Rear left
Left
Rear
right
Right
Below
Attention must be paid to
the downward angle up
of drain hose
E
D
more than 20cm
(6 in.)
(4 in.)
(4 in.)
(8 in.)
(8 in.)
(24 in.)
(6 in.)
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Other Manuals for Haier HSU109VHGG
Summary
Indoor unit Make a hole of B mm / inches in diameter, slightly descending to outside the wall.Install piping hole cover and seal it off with putty after installation When the mounting plate is rst xed 1. Carry out, based on the wall studs or lintels, to be xed against the wall, then temporarily fast...
3 Outdoor unit Install according to the instructions on the 1st page of this manual When bending the interconnect tubing, ensure the radius is at least 1 1/4" to 1 3/4", 30mm to 40mm to ensure against crushing the tubing.Connecting the pipe of gas side rst makes working easier.Ensure the int...
Detach the service port’s cap of 1. 3-way valve, and the valve cap for 2-way valve and 3-way valve. Connect the service port to the low side of the gauge manifold Open the handle on the low side of the gauge manifold and operate vacuum pump. 2. Vacuum the tubing for at least 15 minutes. The vacuum l...