- Page 2 – Selection of pipe; Fitting of the Mounting Plate and Positioning of the wall Hole
- Page 3 – Connecting the indoor/outdoor Electric Cable; Removing the wiring cover; When connecting the cable after installing the indoor unit; Indoor unit; When connecting the cable before installing the indoor unit
- Page 4 – Connection of pipes
No.0010531057
Installation Manual of Room Air Conditioner
Read this manual before installation
1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)
5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife
9.Nipper
12.Reamer
10.Gas leakage detector or
soap-and-water solution
11.Measuring tape
Explain sufficiently the operating means to the user
according to this manual.
A
B
C
D
E
F
G
Optional parts for piping
Mark
Parts name
Non-adhesive tape
Adhesive tape
Saddle(L.S) with screws
Connecting electric cable
for indoor and outdoor
Drain hose
Heating insulating material
Piping hole cover
Arrangement of piping directions
Rear left
Rear
right
Left
Below
Right
No.
Accessory parts
Remote controller
R-03 dry battery
Mounting plate
Drain hose
Steel nail, cement
Screw
Plastic cap
Cover
Cushion
1
1
2
3
4
5
6
7
8
9
2
1
1
6
4
1
4
1
Number
of
articles
Accessory parts
4X50
4X25
Pipe supporting plate
Drawing for the installation of indoor and outdoor units
Necessary Tools for Installation
10
Drain-elbow
1
The marks from to in the figure are the parts numbers.
The distance between the indoor unit and the floor should be
more than 2m.
A
G
Attention must be paid to
the rising up of drain hose
mc
5
na
ht
er
o
m
m
c
0
1
n
a
h
t
e
r
o
m
m
c
0
1
n
a
h
t
e
r
o
m
A
C
m
c
0
1
n
a
h
t
e
r
o
m
m
c
0
6
n
a
h
t
e
r
o
m
m
c
5
1
n
a
h
t
e
r
o
m
m
c
0
1
n
a
h
t
e
r
o
m
D
E
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Selection of pipe To this unit, both liquid and gas pipes shall be insulatedas they become Iow temperature in operation.Use optional parts for piping set or pipes covered withequivalent insulation material. 2 Liquid pipe ( )Gas pipe ( ) 9.52mm(3/8") Floor fixing dimensions of the outdoor unit (U...
Connecting the indoor/outdoor Electric Cable Removing the wiring cover Remove terminal cover at right bottom corner of indoor unit, then take off wiring cover by removing its screws. When connecting the cable after installing the indoor unit 1. Insert from outside the room cable into left side of th...
Outdoor unit 1.Connection of pipes 2.Attaching Drain-Elbow To bend a pipe, give the roundness as large as possible not to crush the pipe Connecting the pipe of gas side first makes working easier. The max vertical distance between the indoor unit and the outdoor unit is 5 m. If the drain-elbow is us...