Haier ES70V-G1(H) - Manual

Haier ES70V-G1(H)

Haier ES70V-G1(H) – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
Page: / 2
Loading the manual

1

2

ES50V-G1(H)
ES70V-G1(H)

ES100V-G1(H)

Proprietary No.

**********

V

Please read this Instruction Manual carefully before use.

Please retain this manual for future reference.

Safety Notices

(Please read before use)

Electrical Diagram

·

Exterior and accessories

·

Technical parameters

Electrical Diagram

Troubleshooting

Symptom

Things to Check

Solutions

No water

1

Whether the water supply has

stopped or whether the water

pressure is too low

Check

2

Whether the water-usage

point is blocked or whether

the hot water valve is opened

Check and clean

Only cold water but

the heating indica-

tor lamp is lit

1

Whether hot water outlet is

not opened

Check and open

2

Whether the water tempera-

ture is adjusted

Increase the temperature to the

required value. Once the water is

heated to the pre-set temperature,

control

ow volume of cold and

hot water using the moderating

mixing valve.

3

Heating time is too short

and set temperature is not

achieved

Continue heating

4

Whetehr heating pipe is

damaged

Con

rm this is not due to the rea-

sons

①②③

, then contact Mainte-

nance Department

Only cold water and

the heating indica-

tor lamp is not lit

1

Whether power is properly

connected

Check power socket

2

Whether thermostat is out of

control

Con

rm that this is not due to rea-

son

, then contact Maintenance

Department

Heating indicator

light is on all the

time

1

Water has not reached the set

temperature

Continue heating

2

Whether thermostat is out of

control

Con

rm it is not due to reason

,

then contact Maintenance Depart-

ment

Water volume is

sometimes large or

small, or water is

sometimes hot or

cold

Whether water pressure

is stable

Set lower mixing valve or ensure

water pressure is stable before

use

Small hot water

out

ow volume

1

Whether the present tempera-

ture setting is too low

Calibrate using the method stipu-

lated in the Instruction Manual

2

Whether water pressure is too

much

Set lower mixing valve

Prohibited

Compulsory

Matters

Essential

Matters

Immediately cut off power supply and

contact our Service Center once the

water heater does not work properly

or emits burnt smell.

This icon is used by Haier

Water Heaters to indicate

"safety warning experts". It

indicates that the product

i s e q u i p p e d w i t h s p e c i a l

technology that constantly

monitors the status of your earth line,

to ensure safety during showering. If

the icon is lit, it means that there is

electricity in the earth line. You should

i m m e d i a t e l y s t o p u s i n g t h e wa t e r

heater and disconnect the power plug.

Do not touch the outer casing of any

electrical appliances in your home.

Remember to also contact the local

After-sales depar tment or proper ty

management company in order for

them to engage quali

ed electricians

to carry out a system check until the

icon is no longer lit.
The product is only available for

To ensure safety, the water heater

should be connected to independent

sockets (do not use adapters), with re-

liable earthing. In addition, the power

socket must conform to national stan-

dards. Use of water heater without

reliable earthing is strictly prohibited.

Use pen multimeter to check whether

the live line and zero line are reverse.

Do not use damaged wire and power

socket. Promptly clean the dust on the

power plug and socket.

Check the power meter and the elec-

tric wire's diameter to ensure that they

comply with the rated current for the

water heater. Where necessar y en-

gage quali

ed electrician to check the

electric circuit.

Do not touch the plug with wet hands,

and make sure that the water heater,

plug socket do not come into contact

with water. If they are accidentally wet,

they must be checked by professions

appointed by our company before us-

ing, in order to prevent electrocution.

Storing of inflammable and explosive

items near the water heater is strictly

prohibited.

Do not connect to power when install-

ing or repairing the water heater.

Non-professionals are strictly prohib-

ited from carrying out repairs, m a i n -

tenance, dismantling or revamping of

the water heater.

Installation of water heater outdoors is

strictly prohibited.

Do not install the water heater in an

environment which is susceptible to

ice-formation. Ice will cause the con-

tainer and water pipe to break, lead-

ing to scalding and water leakage.

Please take precautionary measures

during cold weather, in order to pre-

vent damage to water heater from

freezing.

If the soft power cable is damaged,

it must be replaced by professional

staff from the manufacturers or Main-

tenance Department in order to avoid

danger.

Take care not to be scalded by heated

water.

·

Touching of hot water valve and

pipes is strictly prohibited.

·

Make sure to check the water tem-

perature before use; use only when

it feels suitable.

Do not use water from the water heat-

er for drinking or similar purposes.

Please cut off the power supply if the

water heater was not used for an ex-

tended period of time. Drain the water

heater of all water according to the in-

structions in the chapter on Cleaning

and Maintenance.

Forbidden

Warning

Caution

Caution

6767

w

e

i

v

n

o

it

c

e

s

-

s

s

o

r

C

w

e

i

v

r

a

e

R

w

e

i

v

t

n

o

r

F

Side view

A : Hot water outlet B : Cold water inlet C : Inner chamber

D : Temperature measurement pipe E : Heating pipe

F : Magnesium rod G : Wall hook

E

BT

MT

L

N

EH

E

HL

L : Live wire (brown)

N : Zero line (blue)

MT : Manual-reset thermostat

BT : Adjustable thermostat

HL : Heating indicator light

EH : Heating pipe

E : Earth line (yellow-green;

dual color)

Haier Home Water Heater

Instruction manual

Meanings of Icons

Earthing

Warning

Warning

Warning

Warning

Warning

Caution

Forbidden

Forbidden

Forbidden

Forbidden

Forbidden

Forbidden

Forbidden

CSH10D0037_en.indd 1

0040503115

V

Exterior and accessories

ES100V-R1(H)

Technical parameters

to high respectively.

Model No.

Capacity

(L)

Net

weight(kg)

a1

(mm)

b1

(mm)

c1

(mm)

d1

(mm)

e1

(mm)

f1

(mm)

Note:

1.

The margin of error for the above parameters (measurements, weight) is ±10%.

2. The thermometer is not a precision instrument. It consists of three areas denoted by blue;

orange and red, which indicate the temperature of water in the inner chamber from low

ES50V-G1(H)

Unit

Ltem

ES70V-G1(H) ES100V-G1(H)

Water pressure

2150

0.80

0.80

2150

0.80

2150

ES100V-R1(H)

0.80

2000

MPa

ES50V-G1(H)

ES70V-G1(H)

ES100V-G1(H)

50

70

100

21

26

33

410

410

420
420

410

420

775

980

1300

100

200

220

100

200

480

100

200

730

100

33

410

420

1300

100

200

730

ES100V-R1(H)