1

2

Make 2 holes Φ 12mm, 65mm deep in wall with an

impact drill according to the drawing of the external

dimensions (See Figure 4).
Take out all accessories in packaging liner, unpack

one hook, sleeve the ring end of the connection lines

among the accessories into the hook tightening end

and assemble the hook well.

right hole).
Lift the water heater and hang it with wall rack corresponding to the two hooks. Insert the

connection spacer led from the rear shell wall rack of the heater into the connection terminal

of the line on the hook (See Figure 2).

appropriate locations on inlet and outlet pipes respectively. Find the location requiring hot

water supply. Connect inlet pipe, outlet pipe and city water pipe respectively to the use point

for hot water. Fill the tank with water to check whether there is any leakage. It must be re-

connected if there are signs of water leakage.

Warning:

Do not release your grip unless the wall rack is securely hung on the hook.

Otherwise the heater may fall and cause personal injury or property damage.

Connect the safety valve to the water inlet by following the direction of its arrow (the arrow

should point towards the heater). The safety valve’s rated pressure is 0.80MPa and its connection

is G1/2. Once power is connected and the water is being heated, the water inside the water

tank will expand. In order to relieve the water pressure inside, a very

safety valve. The pressure-relief vent must be free of any blockages.
Please connect the drain hose to the safety valve. Connect one end

of the hose to the safety valve vent and the other end to the sewage

drain. The hose can be cut short or extended as necessary. The hose

shall be installed as inclined downward.

ES15V-P2

ES25V-P2

ES35V-P2

Spa Water Heater

User's Manual

SPEED

SET

TIMER

0040502425

V

SPEED

SET

TIMER

Please read this manual before usage.

Retain it for future reference.

Safety warning (Read carefully before use)

Installa

tion •

Use

Installation must be made by installers of or designated by our company after-service department.
The water heater shall be wall-mounted.

Installation

Installing safety valve

FAQ

Phenomenon

Remedy

No water

No water supply or water pressure

is too low

Check

Water use point is blocked or hot

water valve is closed

Check and clear

Cold outlet water

1

Hot water access close

Check and open

2

Temperature not set to desired

setting

Calibrate the heater according to the

operation instructions in the manual

3

Heating time limit and setting

temperature not obtain

Calibrate the heater by referring to

the operation instructions in the

manual

4

Defective elements

Contact with service department

when

1

,

2

and

3

are excluded.

Not heated to

desired temperature

water

1

Whether the current function

is set to the proper mode and

temperature is set too low.

Calibrate the heater according to the

operation instructions in the manual

2

Excessive water pressure

turned down

temperature of water Inconstant water pressure

turned down or use with constant

water pressure

Incapable of startup

or display not lit

1

No power to heater

Check power socket

2

Defective elements

Contact with service department

when

1

is excluded.

Display E1

Faulty line

Contact with service department

Display E2

1

Power on after disconnection when

2

Defective elements

Contact with service department

when

1

is excluded.

Display E3

1

Room temperature lower than

-20°C

when ambient temperature more

than -19°C

2

Defective sensor

Contact with service department

when

1

is excluded.

Meanings of icons

These are

actions which

are forbidden

These are actions

which must be

carried out

These are matters

for which attention

is required

Forbidden

Warning

CAUTION

If the water heater emits an unusual

smell or a burning smell, please

disconnect the power supply

immediately and call the service center.

This mark is the designation

for Pre-safe Expert of Haier

Water Heater Company,

which indicates the use of

the company's patented

technology inside the product. It ensures

you a safe bath while monitoring whether

your house ground wire is live or not all

the time. If this mark is lit, it indicates your

house ground wire was come live (poor

grounding and live). In this case, please

immediately stop use and disconnect

the power, and remember not to touch

any electric applicance in your house.

At the same time, immediately contact

after-sales service and your property

management company for professional

Non-professional maintenance

personnel shall not carry out

unauthorized repair, maintenance,

dismantling or re-construction of

the heater.

Be sure to use independent socket

and earth it reliably.

In case the power cord of the

water heater is damaged, be sure

to have it replaced by after service

technicians with special cord

If you do not need to use the heater

for a prolonged period, please cut

in the heater in accordance with

the instructions in the chapter on

cleaning and maintenance.

Earthing

Take care not to be scalded by hot water.

Do not touch the valve and pipe for hot

water supply.

Please feel the water temperature before

use. Use only when the temperature is
ideal for you.

Do not set at outdoor places.

Do not install the water heater in the

conditions in which ice could form.

Ice formation will cause the water

container and piping to crack, leading

to scalds and water leakage.

Do not connect or disconnect the power

supply while your hands are wet.

Check if the ammeter and the

diameter of the wires are in

accordance with the rated current

of the water heater. If necessary,

please have it checked by an

experienced electrician.

Do not drink hot water from the

heater or use it for similar purposes.

Do not spray water or steam onto

the heater.

Please take precautionary measures

during cold weather so as to prevent

the heater from being frozen.

reliable wall.

Do not install at places without sewage.

Warning

Warning

Warning

Warning

(Figure 1) for installation

reference only.

Hot water

outlet

Safety valve

Cold water

inlet

Shower

head

Cold

water

outlet

valve

Mixing

Valve

Hot

water

outlet

valve

(Figure 2)

Extended connection line

Wall rack

Expansion

hook

SPEED

SET

TIMER

1

2

3

4

(Figure 1) for installation

reference only.

Cold

water

outlet

valve

Mixing

Valve

Hot

water

outlet

valve

(Figure 2)

Extended connection line

Wall rack

Expansion

hook

Connect to drain hose

(Figure 3)

CAUTION

CAUTION

Forbidden

Forbidden

Forbidden

Forbidden

Forbidden

Forbidden

Forbidden

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Haier Models