Page 2 - Table of Contents
1 Table of Contents Malfunction 7-8 Care and Maintenance 9 For Preparation of Heating("Hot Keep") 10 Is The Unit Installed Correctly 11 Installation Manual For Indoor Unit 12-18 Safety Precautions 3-5 Parts and Functions 6 Cautions 2
Page 3 - Cautions; Disposal of the old air conditioner; Safety Instructions and Warnings
Cautions 2 All electrical repairs must be carried outby qualified electricians. Inadequate repairsmay result in a major source of danger forthe user of the air conditoiner. D o n o t d a m a g e a n y p a r t s o f t h e a i rconditioner that carry refrigerant by piercingor perforating the air condi...
Page 4 - Safety Precautions; CAUTIONS FOR INSTALLATION
Safety Precautions Before starting to use the system, read carefully this"SAFETY PRECAUTIONS" to ensure a proper operation of the system. Safety precautions described here are classified to " WARNING" and " CAUTION". Precautions which are shown in the column of" WANING...
Page 5 - CAUTIONS FOR TRANSFER OR REPAIR
4 CAUTION Do not wash the air conditioner with water. Do not install the system where the air outletreaches directly the flora and fauna. Make sure to use a fuse of proper electricrating. D o n o t o p e r a t e t h e s y s t e m w h i l e t h eair outlet grill is removed. It is strictly prohibited ...
Page 6 - The machine is adaptive in following situation; The connecting cable should be H05RN-F 4G 0.75mm
5 2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. 3. If the fuse on PC board is broken please change it with the type of T 3.15A /250VAC. 4. The wiring method should be in line with the local wiring standard. 1. Applicable...
Page 7 - Parts and Functions; Air outlet
Parts and Functions 6 Air outlet Air inlet Duct Air outlet Air inlet Duct AD182AMBEAAD242AMBEAAD242AMERAAD28NAMBEA AD36NAMBEAAD42NAMBEA
Page 8 - Unit fails to start; Cooling or heating is not sufficient; Malfunction
please check the following things about your air conditioner before making a servie call. Unit fails to start ON OFF Is the power sourceswitch adjust cut in? Is city supply power innormal? Powerstoppage? Isn't the signal receivingsection exposed to thedirect sunlight or strongillumination? Isn't the...
Page 9 - The followings are not malfunction; This is caused by heat expansion or contraction of plastics.
8 The followings are not malfunction Shuru Shuru When the air conditioner is started, when the compressor starts orstops during operation or when the air conditioner is stopped, itsometimes sounds "shuru shuru" or "gobo gobo". It is the flowingsound of the refrigerant, and it is not ...
Page 10 - Care and Maintenance; Points to observe; Turn off the power supply switch.; Cleaning; Care and Cleaning of the unit
9 Care and Maintenance Points to observe Turn off the power supply switch. Do not touch with wet hand. Do not use hot water or volatileliquid. ON OFF Thinner Do notuse! Benzine Tooth powder Cleaning CAUTION Do not dry the air filter with fire.Do not run the air conditioner without the air filter. Do...
Page 11 - When heating is started:; to the ordinary heating mode.; When the room thermostat is actuated:; WARMING OPERATION; Heat pump type warming; drop of outdoor temperature.
10 For Preparation of Heating("Hot Keep") "HOT KEEP"is operated in the following cases. When heating is started: In order to prevent blowing out of cool wind, the indoor unit fan stopped according to the room temperature which heating operation is started. Wait for approx. 2 to 3 min...
Page 12 - Is The Unit Installed Correctly; For inspection and maintenance; Installation place
11 Is The Unit Installed Correctly For inspection and maintenance When you change your address or the installation place Electric work Confirm the following items for safe and comfortable use of air conditioner.The installation work is to be burden on the sales dealer, and do not conduct it by yours...
Page 13 - Installation Manual For Indoor Unit; Safety precautions
12 Installation Manual For Indoor Unit 1. Safety precautions WARNING Please read these "Safety Precautions" first then accurately execute the installation work.Though the precautionary points indicated herein are divided under two headings,and , those points which are related to the strong p...
Page 14 - (3) Avoid installation and use at those places listed below.; Installation space
13 NOTICE All Wiring of this installation must comply with NATIONAL, STATE AND LOCAL REGULATIONS . These instructions do not cover all variations for every kind of installation circumstance. Should further information bedesired or should particular problems occur, the matter should be referred to yo...
Page 15 - (a) Size of hole at ceiling and position of hanging bolts; Use care of the piping direction when the unit is installed.
14 (4) Preparation for suspending the unit (a) Size of hole at ceiling and position of hanging bolts <Combination with silent panel> 57 A B C (Hanging bolt position) (Ceiling hole size) (Panel dimensions) 137 30 30 (Ceiling ~ panelwrap dimensions) (Ceiling ~ panel wrap dimensions) (Hanging bol...
Page 16 - Inproper piping
15 (5) Installation of indoor unit Fix the indoor unit to the hanger bolts.If required, it is possible to suspend the unit to the beam, etc.Directly by use of the bolts without using the hanger bolts. When the dimensions of main unit and ceiling holes does not match, it can be adjusted with the slot...
Page 17 - Drainage Test
16 VP 30 Secure the elevation as high as possible(approx. 100 mm) A downhill grade of1/100 or more Drain hose Joint for VP 25(Local procurement) 600 (Maxi m um local drain up dimension) Right overhead 290~325mm Attached drain hose clamp Drain piping Main unit Drain situation can be checked with tran...
Page 18 - Use the side exhaust port.
17 (7) Installation work for air outlet ducts Calculate the draft and external static pressure and select the length, shape and blowout. A Blowout duct 2-spot, 3-spot and 4-spot with 200 type duct are the standard specifications. Determine thenumber of spots based on following table. Note (1) Shield...
Page 19 - DANGER OF BODILY INJURY OR DEATH; (1) Selection of size of power supply and interconnecting wires.; Item; R S T; L N
18 5. Electric wiring WARNING DANGER OF BODILY INJURY OR DEATH TURN OFF ELECTRIC POWER AT CIRCUIT BREAKER OR POWER SOURCE BEFOREMAKING ANY ELECTRIC CONNECTIONS. GROUND CONNECTIONS MUST BECOMPLETED BEFORE MAKING LINE VOLTAGE CONNECTIONS. (1) Selection of size of power supply and interconnecting wires...