Haier 0010554405B- User Manual

Haier 0010554405B

Haier 0010554405B– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – Selection of Installation Place; Outdoor Unit
  • Page 3 – the plate to the fixed mounting bar.; piping which is marked on heat insulation materials.; Indoor unit
  • Page 4 – Connecting the indoor/outdoor Electric Cable
  • Page 5 – Two ways for the installation of indoor part, as illustrated:
  • Page 6 – Installation of Outdoor Unit; Outdoor unit
  • Page 8 – Insert the flare nut; Power Source Installation; Check Items for Test Run; Flare tooling die
Loading the manual

No.0010554405

B

Installation Manual of Room Air Conditioner

No.

Accessory parts

Remote controller

R-03 dry battery

Mounting plate

Drain hose

Steel nail, cement

Screw

Plastic cap

Drain-elbow

Cover

Cushion

Connecting cable

1

1

A

B

C

D

E

F

G

2

3

4

5

6

7

8

9

10

2

1

1

6

4

1

1

4

1

Number
of
articles

Accessory parts

Optional parts for piping

Mark

Parts name

more than 5cm

more than 10cm

more than 60cm

more than 15cm

Non-adhesive tape

The marks from to in the figure are the parts numbers.

The distance between the indoor unit and the floor should
be more than 2m.

more than 10cm

more than 10cm

more than 10cm

Adhesive tape

Saddle(L.S) with screws

Attention must be paid to
the rising up of drain hose

Arrangement of piping directions

Rear left

Rear

right

Left

Below

Right

Connecting electric cable
for indoor and outdoor

Drain hose

Heating insulating material

4X50

4X25

Piping hole cover

Read this manual before installation

1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)

5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife

9.Nipper

12.Reamer

10.Gas leakage detector or
soap-and-water solution
11.Measuring tape

Explain sufficiently the operating means to the user
according to this manual.

A

G

Change for
fresh air box

Change for
fresh air
tube(suit)

Outlet joint

11

12

13

1

1

2

Screw

6

G

F

A

C

D

E

13

12

Note:1.Cooling only units don't have Drain-elbow

Outlet joint

1

2. is only for the models of 18,22.
3.The models ZF don't have fresh function
and accessory parts related with freshing.

Drawing for the installation of indoor and outdoor units

Necessary Tools for Installation

15

14

14

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Selection of Installation Place; Outdoor Unit

Fixing of outdoor unit Indoor Unit Selection of Installation Place Power Source Selection of pipe Outdoor Unit Fix the unit to concrete or block with bolts( 10mm) and nuts firmly and horizontally. When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nailsor wires in co...

Page 3 - the plate to the fixed mounting bar.; piping which is marked on heat insulation materials.; Indoor unit

Indoor unit 1.Fitting of the Mounting Plate and Positioning of the wall Hole 2.Making a Hole on the Wall and Fitting the Piping Hole Cover When the mounting plate is first fixed When the mounting plate is fixed side bar and lintel 1.Carry out, based on the neighboring pillars or lintels, a proper le...

Page 4 - Connecting the indoor/outdoor Electric Cable

Indoor unit 4.Connecting the indoor/outdoor Electric Cable Fixing the indoor unit body Removing the wiring cover [Other direction piping] Indoor/outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape. Cut away, with a nipper, the lid for piping according to th...

Other Haier Models