Drawing for the installation of indoor and outdoor units
Necessary Tools for Installation
Driver
●
Torque wrench
●
(17mm,22mm,26mm)
Nipper
●
Reamer
●
Hacksaw
●
Pipe cutter
●
Gas leakage detector or
●
soap-and-water solution
Hole core drill
●
Flaring tool
●
Spanner(17,19 and 26mm)
●
Knife
●
Measuring tape
●
Indoor Unit
Place, robust not causing vibration, where the body can be supported suf
fi
ciently.
●
Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the
unit are not disturbed.
●
Place, possible to drain easily, where piping can be connected with the outdoor unit.
●
Place, where cold air can be spread in a room entirely.
●
Place, nearby a power receptacle, with enough space around. (Refer to drawings).
●
Place where the distance of more than lm from televisions, radios, wireless apparatuses
and
fl
uorescent lamps can be left.
●
In the case of
fi
xing the remote controller on a wall, place where the indoor unit can
receive signals when the
fl
uorescent
●
lamps in the room are lightened.
Outdoor Unit
Place, which is less affected by rain or direct sunlight and is suf
fi
ciently ventilated.
●
Place, possible to bear the unit, where vibration and noise are not increased.
●
Place, where discharged wind and noise do not cause a nuisance to the neighbors.
●
Place, where a distance marked
●
is available as illustrated in the above
fi
gure.
Before inserting power plug into receptacle, check the voltage without fail.
The power source is the same as the
●
corresponding name plate.
Install an exclusive branch circuit of the power.
●
A receptacle shall be set up in a distance where the power cable can be
reached. Do not extend the cable by cutting it.
●
Power Source
Preparation
Read this manual before installation
Explain sufficiently the operating means to the user according to this manual
NO.0010506358
Installation Manual of Room Air Conditioner
F
A
C
E
D
Optional parts for piping
Non-adhesive tape
Adhesive tape
Saddle (L.S) with screws
Connecting electric cable
for indoor and outdoor
Drain hose
Heating insulating material
Piping hole cover
Floor
fi
xing dimensions of the
outdoor unit (Unit:mm)
Fixing of outdoor unit
Fix the unit to concrete or block
●
with bolts (10mm) and nuts
fi
rmly
and horizontally.
When
fi
tting the unit to wall
●
surface, roof or rooftop,
fi
x
a supporter surely with nails
or wires in consideration of
earthquake and strong wind.
If vibration may affect the
●
house,
fi
x the unit by attaching a
vibration-proof mat.
The marks from
to
in the
fi
gure are the
parts numbers.
The distance between
the indoor unit and the
fl
oor should be more
than 2m.
The models adopt HFC free refrigerant R410A
more than
10cm
more than 5cm
more than 10cm
more than 10cm
more than10cm
more than15cm
more than 60cm
A
G
●
●
A
F
C
E
D
G
B
Arrangement of piping
directions
Rear left
Left
Rear
right
Right
Below
G
Please be subject to the actual product purchased , the above picture is just for your reference.
Attention must be paid to
the rising up of drain hose
113.5
583
113.5
5.
91
3
Selection of Installation Place
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.