Graco 288420 - Manual
A user manual for high-performance contractor-grade spray guns like the Graco Contractor & FTx series outlines critical safety protocols, operational guidelines, and maintenance procedures. The document emphasizes hazards such as skin injection risks, fire/explosion dangers, and pressurized aluminum components, requiring strict adherence to precautions like proper ventilation, pressure limits, and protective gear. It also covers essential topics like equipment setup–including trigger locks, tip installation, and pattern alignment–to ensure safe and effective use while addressing common operational challenges like clog clearing. Technical details such as maximum working pressures and material specifications are included but remain secondary to broader safety and functional guidance.
Table of Contents:
- Page 1 – Safety Instructions for Spray Guns
- Page 2 – Sprayer Setup and Operating Procedures
- Page 3 – Operational Alignment and Parts Lists
- Page 4 – Maintenance, Repair, and Technical Specifications
For the application of architectural paints and coatings.
Maximum Working Pressure: 3600 psi (248 bar, 24.8 MPa)
IMPORTANT SAFETY INSTRUCTIONS.
Read all
warnings and instructions in this manual. Refer to your
sprayer instruction manual for Pressure Relief, priming and
spray instructions. Save all instructions.
ti8501b
ti8522b
Instructions-Parts
Contractor & FTx Spray Guns
Contractor Models: 288420, 288421, 288425, 288475, 288477, 288478, 826085, 288009
FTx Models: 288427, 288428, 288429, 288430, 288431, 288436, 288438, 288477,
288478, 826086, 288008,262114, 262116
311861G
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol
alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional,
product-specific warnings may be found throughout the body of this manual where applicable.
WARNING
SKIN INJECTION HAZARD
High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it
is a serious injury that can result in amputation. Get immediate surgical treatment.
•
Do not point gun at anyone or at any part of the body.
•
Do not put your hand over the spray tip.
•
Do not stop or deflect leaks with your hand, body, glove, or rag.
•
Do not spray without tip guard and trigger guard installed.
•
Engage trigger lock when not spraying.
•
Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or
servicing equipment.
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and
explosion:
•
Use equipment only in well ventilated area.
•
Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths
(potential static arc).
•
Keep work area free of debris, including solvent, rags and gasoline.
•
Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present.
•
Ground all equipment in the work area. See Grounding instructions.
•
Use only grounded hoses.
•
Hold gun firmly to side of grounded pail when triggering into pail.
•
If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you iden-
tify and correct the problem.
•
Keep a working fire extinguisher in the work area.
PRESSURIZED ALUMINUM PARTS HAZARD
Use of fluids that are incompatible with aluminum in pressurized equipment can cause a serious chemical reation and
equipment rupture. Failure to follow this warning may result in death, serious injury, or property damage.
• Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids contain-
ing such solvents.
• Many other fluids may contain materials that are incompatible with aluminum. Contact your material supplier for
verification.
II 2 G
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Was this manual helpful?
About this manual
- Brand
- Graco
- Model
- 288420
- Document type
- Manual
- Language(s)
- English
- Pages
- 4
- File size
- 579.2 KB
- Format
Summary
Safety precautions regarding hazards like skin injection, fire, explosion, and pressurized aluminum parts. Guidelines include avoiding pointing the gun at people, ensuring ventilation, avoiding incompatible fluids, and maximum working pressure specifications.
Warnings for equipment misuse, required personal protective equipment, pressure relief steps, trigger lock usage, connecting accessories, installing tips and guards, and the correct method for spraying.
Instructions for aligning spray patterns, clearing clogs, and detailed parts lists with diagrams for contractor-grade spray guns and accessories for models RAC X and RAC 5.