Page 2 - Table of Contents
2 Table of Contents Performance Data Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 How To Use This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Safety Informa...
Page 3 - Performance Data Sheet; PENTAIR Residential Filtration, LLC
3 Performance Data Sheet Pro Elite Analyzer Water Softener System Performance Data Sheet Model Pro Elite 268-716-100-1044 Analyzer Pro Elite 268-716-150-1248 Analyzer Pro Elite 268-716-200-1248 Analyzer Rated Service Flow (gpm) 8.0 13.0 15.0 Pressure Drop at Rated Ser-vice Flow Rate (psi) 5.5 9.5 14...
Page 4 - How To Use This Manual; Icons That Appear In This Manual; Safety Information; Do not use pliers or pipe
4 How To Use This Manual This installation manual is designed to guide the installer through the process of installing and starting water conditioning systems featuring Pro Elite equipment. This manual is a reference and will not include every system installation situation. The person installing thi...
Page 5 - The valve and tank
5 WARNING: The valve and tank components of this Pro Elite unit have been assembled and tightened to the proper factory torque specifications. Over tightening may result in improper valve, probe and tank alingnment and may damage the tank O-ring (PN1010154) • Keep the media tank in the upright posit...
Page 6 - Front; Model Number
6 Valve Layout Analyzer Control Layout System Specifications 716 Motor Injector Screen Filter Backwash Drain Control Inlet Drain Outlet Camshaft Optical Sensor Valve Discs One Piece Valve Disc Spring Analyzer Control Injector and Cap Regenerant Tube Connection Refill Controller Time/Day Regeneration...
Page 8 - System Features; Resin Tank
8 System Features Resin Tank Brine Tank 1 Cover 9 Foot , Leveling 2 Cap, Cover 10 Latch Mechanism 3 Jacket ,Resin Tank 11 Tank Collar 4 Base 12 Riser Tube 5 268 Logix PE Valve w/716 Control 13 Upper Basket 6 Resin Tank 14 Cover 7 Door, Access, Sensor 15 Shield 8 Sensors Wired Probes 1 2 3 4 5 6 7 8 ...
Page 9 - Equipment Installation; Dimensions
9 Equipment Installation Dimensions 36.9 (938.1) 60.7 (1541.6) 28.2 (715.9) 32.2 (817.5) 53.4 (1356.6) 55 (1398.1) 5.0 (127) 2.5 (63.5)
Page 10 - Typical System Layout; Figure 2 Softened Water Flow Diagram.
10 Typical System Layout Figure 1 Standard Basement Before Installation. Cold water lines shown. Figure 2 Softened Water Flow Diagram. Laundry Tubs Pump or Meter Hot Water Outlet Outside Faucet Outside Faucet Water Heater Bath Tub Lavatory Toilet Kitchen Floor Drain Soft Water Hard Water Outside Fau...
Page 11 - Inspection; To Assemble the Salt Tank:; Tank and Probe Assembly
11 Inspection The Pro Elite system is shipped with several parts unassembled. When parts are removed from the packing, they should be inspected for damage. If any parts are damaged or missing, contact your supplier. WARNING: When handling the media tank do not turn it upside down or drop on its side...
Page 12 - Water Line & Bypass Connections; Normal Operation
12 Figure 5 Figure 6 Water Line & Bypass Connections A bypass valve system should be installed on all water conditioning systems. A model 1265 bypass is included with this system. The bypass valve isolates the conditioner from the water system and provides unconditioned water to service during r...
Page 13 - Right Way
13 Drain Line Connection Note: Standard commercial practices are expressed here. Local codes may require changes to the following suggestions. Check with local authorities before installing a water conditioning system 1. The unit should be above and not more than 20 feet (6.1 m) from the drain. Use ...
Page 15 - System Operation; Repressurization – Cycle C4; nd; Regenerant Refill Last – Cycle C8; Cycle Water Flows
15 System Operation Treated Water (Downflow) Untreated water is conditioned as it flows through the resin bed and up the riser. If the model selected at first start-up was 268r, this is a system that will refill the salt tank at the start of a regeneration cycle. When a regeneration cycle begins, th...
Page 16 - Camshaft Cycle Positions; Valve Disc Location/Function
16 Camshaft Cycle Positions The front end of the camshaft has an indicator cup. The cup has slots in the outer edge and cycle numbers on the inside face (Figure 13). Remove the cover and look over the top of the Analyzer control to view the cycle numbers. The number at the top indicates the current ...
Page 17 - Sodium or Calcium Hypochlorite; . If stronger solutions are used, such as those sold; Regenerant tank conditioners; Calcium Hypochlorite; A. Backwash the conditioner and add the
17 Disinfection of Water Conditioning Systems The materials of construction in the modern water conditioning system will not support bacterial growth, nor will these materials contaminate a water supply. During normal use, a conditioner may become fouled with organic matter, or in some cases with ba...
Page 18 - Button Functions; For Regeneration
18 Displays, Icons & Cursors Note: In normal operation and during programming, only a few of the icons will actually be displayed. 1. Used to select and indicate the actual Day of the Week setting. 2. This cursor is displayed when programming the Days Override. 3. PM indicator displayed when set...
Page 19 - Programming Overview; Level I Used to program control for normal applications..; Analyzer Control Operation; Power Loss Memory Retention; Level I Programming; Day of Week: Set to actual day of the week.
19 Programming Overview The Analyzer control includes multiple program levels that allow the Water Treatment Professional to customize the system for many water conditions. Additionally, historical data can be viewed allowing quick and easy troubleshooting. In most cases, Level I programming is all ...
Page 20 - Level l Programming - Analyzer Conditioner; Pre; Programming i; Service Di
20 Level l Programming - Analyzer Conditioner Note: Upon completing the Level l Programming, the Regen Icon will begin flashing indicating that a delayed regeneration will occur at the next programmed time of regeneration. If a delayed regeneration is not desired, press the REGEN Button to disable t...
Page 22 - Level lll Cycle Programming – C Values
22 Level lll Cycle Programming – C Values Several Level III program parameters can be adjusted to fine-tune a conditioners operation for non-standard applications. Typically these parameters will not need to be adjusted, as the default settings accommodate most applications. Contact your Water Treat...
Page 23 - System Capacities; Description
23 Level IV Viewing History - H Values Historical information can be viewed by pressing the SET and DOWN buttons simultaneously with the Analyzer control in the home position. Release both buttons when the control displays an “H” value. Press the UP or DOWN buttons to navigate to each setting. Progr...
Page 24 - Placing 268 Water Conditioning System; Quick Cycling the Analyzer Control
24 Placing 268 Water Conditioning System Into Operation (Fill Brine Tank Last) Quick Cycling the Analyzer Control It is required that the control be quick cycled to specific regeneration cycles when placing the conditioner into operation. Please review the following instructions for quick cycling th...
Page 26 - The Water Conditioning System is Now; Cycle Description
26 6. Fill the media tank with water. A. While the controller is in the backwash (C1) cycle, open the water supply valve very slowly to approximately the 1/4 open position. WARNING: If opened too rapidly or too far, media may be lost out of the tank into the valve or the plumbing. In the ¼ open posi...
Page 27 - Manual Regeneration Options; Delayed Manual Regeneration
27 Manual Regeneration Options The Analyzer control features several options that offer additional flexibility for manually regenerating the conditioner. Delayed Manual Regeneration Pressing and releasing the REGEN button starts a delayed manual regeneration. The Regeneration icon on the display wil...
Page 28 - Pro Elite Valve Exploded View & Parts List
28 Pro Elite Valve Exploded View & Parts List B Y PA S S B Y PA S S 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 12 21 22 23 24
Page 31 - Kits
31 Kits Item Part Number Description Qty. Item Part Number Description Qty. 1 4000584 Cover, 268/716 Valve 1 17 CH34199 Tank Assembly with Sensors 12 x 48 1 2 4000585 Shield, Decorative, Performa Logix Valve 1 CH34200 Tank Assembly with Sensors 10 x 44 1 3 4000586 Assembly, Cover Plate with Labels 1...
Page 32 - Brine Well Assembly Exploded View & Parts List CH15675; Item
32 Brine Well Assembly Exploded View & Parts List CH15675 1 2 3 4 6 7 8 5 8 Item Part Number Description Qty. 1 CH15013-1 Brine Well w/Slots 1 2 CH15062 Safety Brine Valve 1 3 CH15070 Grommet 2 4 CH16371-60 Tubing, 3/8" x 60" Long 1 5 CH15024 Cap, Brine Well 4" Dia. (Caplug STP -4) 1...
Page 33 - Troubleshooting; Analyzer Control – Error Codes & Check Salt Light; Problem
33 Troubleshooting Analyzer Control – Error Codes & Check Salt Light Problem Possible Cause Solution ERR 1 is displayed. Program settings have been corrupted. Press any key and reprogram Level I settings. ERR 2 is displayed. The control is not a “North American” 60 Hz model. Install 60 Hz Analyz...
Page 34 - System Troubleshooting
34 System Troubleshooting Problem Possible Cause Solution Regenerant tank overflow. a. Uncontrolled refill flow rate. b. Air Leak in regenerant line to air check. c. Drain control clogged with resin or other debris. a. Remove refill flow control to clean ball and seat . b. Check all connections in r...
Page 36 - Pentair Residential Filtration, LLC
©2011 Pentair Residential Filtration, LLC P/N 4001051 Rev B FE11 Pentair Residential Filtration, LLC 5730 North Glen Park RoadMilwaukee, WI 53209-4454 USA(262) 238-4400 Phone (262) 238-4402 Fax