Page 2 - Introduction
Introduction For many years GE Lighting has been a leading supplier to the various sectors which make up the entertainment lighting industry. GE Lighting have an ongoing strategy of product innovation and improvement to meet the demands and applications of O.E.M.s and end users. This updated catalog...
Page 3 - Contents; Notes
Symbols 2 - 3 PAR Lamps 4 - 17 Single Ended Halogen Lamps 18 - 35 Linear Halogen Lamps 36 - 43 Specialist Projector Lamps 44 - 61 Discharge Lamps 62 - 77 Technical Information 78 - 111 Index 112 - 132 GE Lighting World Addresses 133 - 138 Contents G E L I G H T I N G - E N T E R TA I N M E N T L I G...
Page 4 - Symbols
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 2 Symbols English Français Italiano Español Deutsch English Français Italiano Español Deutsch mm 10% 50% CCT CRI ANSI ANSI Codice ANSI ANSI ANSI-Code Beam 10% Faisceau 10% Apertura del fascio Haz 10% Austrahlwinkel 10% al...
Page 6 - PAR Lamps
4 G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E PAR lamps provide a robust and flexibledesign solution for a wide range of theatre,studio and nightclub applications. PAR Lamps PAR 36 6 - 8 PAR 46 9 -10 PAR 56 11 - 12 PAR 64 13 - 17 Twister, Wilhelmshafen, Germany By ...
Page 7 - Lampes Par
PAR Lampen Par Lampen bieten eine robuste undflexible Designlösung für eineumfangreiche Anwendung anTheater-,Studio- und Nachtclub-Anwendungen . Lámparas PAR Las lamparas PAR son una soluciónrobusta y a la vez flexible cuando serealizan diseños de iluminación entodo tipo de teatros, escenarios,disco...
Page 9 - PAR 36 Screw Terminal cap
PAR 36 Screw Terminal cap Peak Approx. Beam Spread Rated Intensity Colour 10% 50% Average Pack Product Watts Volts Order Code CD Temp. K Peak CD Peak CD Life Hours Quantity Notes Code 0.5 Amp 4 . 7 4 5 4 6 6 3 0 0 – 3 x 3 – 1 0 0 0 1 2 – 2 4 7 8 0 12.5 Amp 4 . 7 5 4 5 4 7 2 0 0 0 0 – 3 x 3 – 1 0 0 1...
Page 10 - continued; PAR 36 Screw Terminal cap continued
8 G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E PAR Lamps continued PAR 36 Screw Terminal cap continued Peak Approx. Beam Spread RatedIntensity Colour 10% 50% Average Pack Product Watts Volts Order Code CD Temp. K Peak CD Peak CD Life Hours Quantity Notes Code 5 0 2 ...
Page 11 - PAR 46 Screw Terminal cap
9 G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E PAR 46 Screw Terminal cap Peak Approx. Beam Spread Rated Intensity Colour 10% 50% Average Pack Product Watts Volts Order Code CD Temp. K Peak CD Peak CD Life Hours Quantity Notes Code 3 0 6 . 4 4 5 3 5 9 5 0 0 0 – 5 . 5...
Page 12 - PAR 46 Medium Side Prong cap
10 G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E PAR Lamps continued PAR 46 Medium Side Prong cap Peak Approx. Beam Spread Rated Intensity Colour 10% 50% Average Pack Product Watts Volts Order Code CD Temp. K Peak CD Peak CD Life Hours Quantity Notes Code 1 5 0 1 2 5...
Page 13 - PAR 56 Screw Terminal cap
11 G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E PAR 56 Screw Terminal cap Peak Approx. Beam Spread Rated Intensity Colour 10% 50% Average Pack Product Watts Volts Order Code CD Temp. K Peak CD Peak CD Life Hours Quantity Notes Code 1 0 0 1 2 4 5 4 5 2 2 5 0 0 0 – 9 ...
Page 15 - PAR 64 Screw Terminal cap
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 13 PAR 64 Screw Terminal cap Peak Approx. Beam Spread Rated Intensity Colour 10% 50% Average Pack Product Watts Volts LIF Code Order Code CD Temp. K Peak CD Peak CD Life Hours Quantity Notes Code 2 5 0 2 8 4 5 5 2 5 0 0 0...
Page 21 - HPL; Lámparas Halogenas Bipin
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 19 T19 HPL GKV Einseitig-gesockelte Halogenlampen Eine umfassende Auswahl anLampen wurde entworfen, umeine optimale Leistung in derheutigen Präzisionsauswahl anBühnen-, Studio- undarchitektonischer Beleuchtungzu bieten. L...
Page 22 - Single Ended Halogen; High Performance Lamps
20 G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E Single Ended Halogen High Performance Lamps Approx. A B C Rated Initial Colour Filament Type Length Diameter LCL Average Pack Product Fig. Watts Volts Order Code Lumens Temp. K Form H x W mm mm mm Life Hours Quantity C...
Page 24 - Continued
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 22 Single Ended Halogen Continued B A C B A C Fig. 1 Fig. 2 GY9.5 base - Grid-form Filament Approx. A B C Rated LIF Initial Colour Filament Type Length Diameter LCL Average Pack Product Fig. Watts Volts Code Order Code Lu...
Page 25 - Coiled Coil Filament
23 G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E GY9.5 base - Grid-form filament Approx. A B C Rated LIF Initial Colour Filament Type Length Diameter LCL Average Pack Product Fig. Watts Volts Code Order Code Lumens Temp. K Form H x W mm mm mm Life Hours Quantity Note...
Page 34 - Twin filament
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 32 Single Ended Halogen Continued B A C Fig. 1 GX38q base - Twin filament Approx. A B C Rated LIF Initial Colour Filament Type Length Diameter LCL Average Pack Product Fig. Watts Volts Code Lumens Temp. K Form H x W mm mm...
Page 35 - Frosted, Coil Filament
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 33 B A B A C Fig. 1 Fig. 2 E40 base - Clear, Coil Filament Approx. A B C Rated LIF Initial Colour Filament Type Length Diameter LCL Average Pack Product Fig. Watts Volts Code ANSI Code Lumens Temp. K Form H x W mm mm mm L...
Page 38 - Linear Halogen Lamps; Double-Ended Quartzline
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 36 This precision range of quartzlinelamps are widely used in televisionbroadcast studios around the world. Linear Halogen Lamps Double-Ended Quartzline ® Length 79.4 mm 38 Length 95.3 mm 39 Length 119.1 mm 40 Length 142....
Page 39 - Stabförmige Halogenlampen
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 37 DXX P2/13 Stabförmige Halogenlampen Die Genauigkeit derQuarzlampen sind weltweit inden Fernsehstudios verbreitet. Lámparas HalógenasLineales Este rango de lámparas de cuarzode alta precisión es ampliamenteutilizado en ...
Page 40 - Linear Halogen
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 38 Double-Ended Quartzline ® Lamps with R7s Caps A B 11.4 Fig. 1 Length 79.4mm Approx. A B Rated LIF Initial Colour Filament Lighted Length Diameter Average Pack Product Fig. Watts Volts Code Order Code Lumens Temp. K For...
Page 42 - Burn Horizontal ±4°
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 40 A B 10.2 Fig. 1 Length 119.1mm - Burn Horizontal ±4° Approx. A B Rated LIF Initial Colour Filament Lighted Length Diameter Average Pack Product Fig. Watts Volts Code Order Code Lumens Temp. K Form Length mm mm Life Hou...
Page 43 - Burn Horizontal ±4° – R X 7 s C a p s
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 41 A B 25 Fig. 2 Length 142.9mm - Burn Horizontal ±4° – R X 7 s C a p s Approx. A B Rated LIF Initial Colour Filament Lighted Length Diameter Average Pack Product Fig. Watts Volts Code Order Code Lumens Temp. K Form Lengt...
Page 46 - Specialist Projector Lamps
44 G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E A full range of specialist projectionlamps designed to deliverexcellent optical performanceand reliability. Specialist Projector Lamps Single-ended Quartzline ® 46 - 47 A1 class projector 48 G17q 49 Low volt single end...
Page 47 - Specialist Projector; Projektionslampen
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 45 Specialist Projector Single Ended Capsules Projector Projektionslampen Eine komplette Auswahl anspeziellen Projektionslampen,entworfen um eineausgezeichneten optischenPerformance undVerlässlichkeit zu bieten. Lámparas ...
Page 49 - Single-ended Quartzline
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 47 Single-ended Quartzline ® - Projector Lamps Approx. Source Approx. A C Rated ANSI LIF Initial Operating Size Colour Length LCL Average Pack Product Fig. Watts Volts Code Code Lumens Position Filament WxH Temp. K mm mm ...
Page 50 - A1 Class Projector Bulbs
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 48 B C A B C A Fig. 1 Fig. 2 A1 Class Projector Bulbs Approx. A B C Rated LIF Initial Operating Length Diam. LCL Average Pack Product Fig. Watts Volts Code Lumens Position Filament mm mm mm Life Hours Cap Quantity Notes C...
Page 52 - Single-ended Tungsten Halogen Lamps
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 50 Single-ended Tungsten Halogen Lamps B C A B C A Fig. 2 B C A Fig. 1 Fig. 3 Low Voltage single-ended capsule A B C Rated Length Diameter LCL Average Colour Average Pack Product Fig. Watts Volts LIF Code mm mm mm Lumens ...
Page 53 - Mains Voltage single-ended capsule
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 51 B C A Fig. 4 Fig. 5 B C A Mains Voltage single-ended capsule A B C Rated Length Diameter LCL Average Colour Average Pack Product Fig. Watts Volts LIF Code mm mm mm Lumens Temp. K Cap Filament Life Hours Quantity Notes ...
Page 54 - Double-ended lamps with R7s caps
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 52 Double-ended lamps with R7s caps A B Fig. 1 Linear Projector Lamps Rated A B Approx. ANSI LIF Primary Average Length Diam. Colour Pack Product Fig. Watts Volts Code Code Application Life Hours Filament mm mm Temp. K Qu...
Page 55 - MR-16 Faceted Dichroic Reflector; Quartzline
MR-16 Faceted Dichroic Reflector Rated A B Approx. ANSI LIF Primary Average Focal Length Diam. Colour Pack Product Fig. Watts Volts Code Code Application Life Hours Distance Filament mm mm Temp. K Cap Quantity Notes Code No. 3 0 1 0 . 8 E K Z – 1 6 m m p r o j e c t i o n 2 0 0 4 0 C - 6 4 4 . 4 5 5...
Page 56 - MR-16 Faceted Dichroic Reflector continued
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 54 MR-16 Faceted Dichroic Reflector continued Rated A B Approx. ANSI LIF Primary Average Focal Length Diam. Colour Pack Product Fig. Watts Volts Code Code Application Life Hours Distance Filament mm mm Temp. K Cap Quantit...
Page 57 - MR-16 Dichroic Reflector
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 55 MR-16 Dichroic Reflector Rated Typical A B Approx. ANSI LIF Primary Average Working Length Diam. Colour Pack Product Fig. Watts Volts Code Code Application Life Hours Distance Filament mm mm Temp. K Cap Quantity Notes ...
Page 61 - MR-13 Faceted Dichroic Reflector
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 59 MR-13 Faceted Dichroic Reflector Rated Typical A B Approx. ANSI LIF Primary Average Working Length Diam. Colour Pack Product Fig. Watts Volts Code Code Application Life Hours Distance Filament mm mm Temp. K Cap Quantit...
Page 62 - G7.9 Vented Cap Reflector Quartzline
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 60 A B Fig. 1 G7.9 Vented Cap Reflector Quartzline ® MR-14 Dichroic Reflector Rated Typical A B Approx. ANSI LIF Primary Average Working Operating Length Diam. Colour Pack Product Fig. Watts Volts Code Code Application Li...
Page 63 - High Intensity Arc
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 61 High Intensity Arc Typical Rated Approx. ANSI Working Average Colour Pack Product Fig. Watts Volts Code Description Bulb Cap Distance Life Hours Temp. K Qty Notes Code No. 3 0 0 3 5 E Z G G e m i n i 3 0 0 ( E Z G ) Q ...
Page 64 - Discharge Lamps; CSS compact 66
62 G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E ConstantColor™ CMHlamps represent thelatest advance indischarge lightingtechnology for use in awide range of stage andstudio applications. Discharge Lamps CMH (Ceramic Metal Halide) 64 - 65 CSS compact 66 CSI/CID 67 G2...
Page 65 - Hochdruckentladungslampen
63 CMH PAR CMH 150w CSI G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E Hochdruckentladungslampen ConstantColor CMH Lampenvertreten den neuestenFortschritt in derHochdruckentladungstechnologiefür die Nutzung einer großenAuswahl an Bühnen- undStudio-Anwendung. Lámparas ...
Page 66 - Discharge lamps; Single Ended ‘Minis’
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 64 Discharge lamps Ceramic Metal Halide (CMH) Burn Average Initial Product Product Fig Watts CCT ˚K CRI Ra Lamp Base Finish Position Rated Hours Lumens Description Code No. Single Ended ‘Minis’ 35 3000 80+ – G8.5 CLEAR UN...
Page 67 - Double Ended
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 65 Double Ended Burn Average Initial Product Product Fig Watts CCT ˚K CRI Ra Lamp Base Finish Position Rated Hours Lumens Description Code No. 70 3000 80+ T6 Rx7s CLEAR HORIZONTAL ± 45 15000 7000 CMH70/TD/UVC/830/Rx7s 369...
Page 68 - CSS
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 66 Discharge lamps continued Fig. 1 Fig. 2 B C A B C A CSS Approx. A B C Rated Initial Colour Length Diameter LCL Average Pack Watts Volts Order Code Lumens Temp. K mm mm mm Life Hours Quantity Base 1 4 0 8 5 CSS150/850/G...
Page 69 - Special bipin base
Special bipin base (2 pin 9mm) Average Colour Colour Arc Code Lumens Life Colour Chromaticity Rendering Burning Gap Lamp Watts Ref. 100 hrs Maintenance Hours Temp. K Co-ordinates Index Ra Position Width Base Volts 4 0 0 1 0 0 9 9 - 0 2 0 1 3 2 0 0 0 8 5 % a t 5 0 0 h r s 5 0 0 4 0 0 0 ± 4 0 0 X 0 . ...
Page 72 - Special Bipin base
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 70 Special Bipin base Average Colour Colour Arc Code Lumens Life Colour Chromaticity Rendering Burning Gap Lamp Watts Ref. 100 hrs Maintenance Hours Temp. K Co-ordinates Index Ra Position Width Volts 2 0 0 7 0 9 9 - 0 2 1...
Page 80 - Technical information
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 78 Technical information Explanation of lamp codes 79 - 80 Tungsten halogen lamps 81 - 82 Rated average life 83 - 86 Operating notes 87- 88 He...
Page 81 - designed for use with slide, film and overhead projectors.; types intended for use in Fresnel/ellipsoidal luminaires etc.; Explanation of lamp codes
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 79 Lamps listed in this catalogue are those designed for use as follows: A1 Prefix - L.I.F. (Lighting Industries Federation) reference indicat...
Page 82 - Special and Experimental Lamps
80 G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E Special and Experimental Lamps In addition to these standard ranges, a number of similar types are available to special order and inmost cases, a minimum order quantity will apply. These include non-standard voltage ra...
Page 83 - Incandescent tungsten halogen lamps; Filament Format; The listings use the following codings for filament shape:
81 G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E Incandescent tungsten halogen lamps Filament Format The listings use the following codings for filament shape: S.C. - Axial Single Coil - e...
Page 84 - CP Range of Lamps for Fresnel and Spotlight Fittings
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 82 CP Range of Lamps for Fresnel and Spotlight Fittings As the result of extensive and sustained development work, much of it original, GE are able to offer acomprehensive range of lamps of quartz construction, operating ...
Page 85 - Rated Average Life; ‘T’ Class Lamps for Theatre Spotlight Fittings
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 83 Rated Average Life Average life ratings of Projection Lamps are based on closely controlled laboratory tests oflamps, at their rated voltage, over a long period of production time. Rated Average Life is notnecessarily ...
Page 86 - Typical Working Distance; and other reflector lamps and MARC
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 84 Typical Working Distance For Multi-Mirror ® and other reflector lamps and MARC ™ lamps, the Working Distance shown is the distance from the front surface of the reflector rim to the film plane, in the optical system fo...
Page 87 - Approximate Initial Lumens
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 85 Approximate Initial Lumens The value shown is based on spherical photometry, at rated voltage, of lamps that have beenseasoned for approximately 15% (or a minimum of 2 hours) or more of their rated average life. Approx...
Page 88 - Important Notice
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 86 Important Notice This catalogue contains accumulated data to January 2000. Additional information is constantly beinguncovered through research and testing, which may modify the data given herein. This is particularlyt...
Page 89 - Operating Notes; Operating precautions; - Base Down To Horizontal. Do not operate with base above horizontal.; Horiz
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 87 Operating Notes Caution notices are included with all lamps. Users are urged to read and comply with these. Operating precautions All lamps in this catalogue must be operated with a series fuse in the circuit, as direc...
Page 90 - ANY
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 88 Axial coiled coil single ended lamps will generally give better reliability againstpremature arcing if orientations in which the main support spine is under the filament areavoided. ANY VBD VBD=45° VBD=90° VBD=105° HOR...
Page 91 - Health and safety guide; Special Precautions for Quartz Halogen and Discharge Lamps; removing and/or replacing the lamp or fuse.
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 89 Health and safety guide Special Precautions for Quartz Halogen and Discharge Lamps 1 To avoid any possibility of electrical shock, disconnect the equipment from the power supply before removing and/or replacing the lam...
Page 93 - Filament designation
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 91 Planar (MP) C13 Monoplane Filament designation The configuration of the filaments in all tungsten filament lamps is identified by a prefix letter orletters, followed by a number. The letter indicates whether the wire i...
Page 94 - Lamp caps
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 0 Lamp caps Typical caps used on the Photographic lamps listed in this catalogue are shown below along withtheir IEC codes and normal names or common abbreviations. The IEC codes are used in themajority of table entries. ...
Page 95 - Lamp Comparison and Construction; Lamps for Ellipsoidal Spotlights
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 93 Lamp Comparison and Construction Lamps for Ellipsoidal Spotlights A problem is encountered with some ellipsoidal spotlight luminaires due to the fact that a portion ofthe reflected beam of light is directed onto the ca...
Page 96 - Hard glass Halogen compared with Quartz Halogen
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 94 Hard glass Halogen compared with Quartz Halogen The tungsten halogen principle is now so well known and documented elsewhere that it is consideredunnecessary to describe it here. However should you require details of t...
Page 97 - Biplane or Monoplane?
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 95 Biplane or Monoplane? The filament format of a lamp will have an effect on the beam performance of a luminaire. In Fresnel optics a biplane filament will, due to its smaller area, produce a narrower spot of slightlyinc...
Page 98 - Arc Prevention in Tungsten Halogen Studio Lamp Applications
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 96 Arc Prevention in Tungsten Halogen Studio Lamp Applications Almost all production personnel in the film and television industry have at some time encountered suddenfailure of incandescent studio lamps. When this occurs...
Page 99 - Lamp performance as a function of operating voltage
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 97 Lamp performance as a function of operating voltage Tungsten halogen lamp performance (light output, power consumption, life, colour, temperature) is astrong function of operating voltage. The rated performances claime...
Page 100 - A typical high wattage studio lamp; Lamp comparison and construction
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E A typical high wattage studio lamp A typical 4 pin twin filament studio lamp Exhaust tip off Quartz bridge Quartz envelope Filament Gas filling Support Seal tube Pinch seal Flexible leadCeramic base Contact pin Exhaust ti...
Page 104 - Total spectral energy distribution of typical
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 102 100 80 60 40 20 0 300 400 500 600 700 800 wavelength (nm) relative energy Total spectral energy distribution of typical studio lamp Spectral energy distribution can be shown in absolute terms whereasradiation in terms...
Page 105 - light; From Typical Dimmer System; From constant current source; Turn on time of studio lamps
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 103 100 80 60 40 20 0 0.5 1.0 1.5 2.0 time (sec) light 2.5kW 5kW 2.5kW 5kW From mains From Typical Dimmer System 2.5 kW 5k W From constant current source Turn on time of studio lamps GE S&S 2000 9/03/00 9/3/00 1:32 pm...
Page 106 - Surge Current
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 104 Surge Current The cold resistance of a halogen studio lamp is approx. 1/17 of its value in normal operation. On switch on,theoretically a surge current of 17 √ 2 x the normal current would flow and depending on the th...
Page 107 - Fusing of Tungsten Halogen Studio and Theatre Lamps
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 105 Fusing of Tungsten Halogen Studio and Theatre Lamps A lamp normally fails at end of life by fusing of the filament. Often an arc then forms and as there islittle resistance to limit the current this rises to a very hi...
Page 109 - Compact Iodide Daylight (CID) Discharge Lamps
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 107 Compact Iodide Daylight (CID) Discharge Lamps With a colour temperature of 5500K these lamps provide an excellent simulation of daylight. Forlocation filming, colour matching with natural light presents no problem. In...
Page 111 - Operating Temperature of Discharge Studio Lamps; an increasing extent.; Cap/bulb interface capsule lamps - 450° maximum; cause of short life due to seal failure.; Bulb; and lamp performance will be impaired.
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 109 Operating Temperature of Discharge Studio Lamps The following maximum and minimum temperatures are suggested for optimum life. Operation outside of these figures will not necessarily cause immediate failure but will e...
Page 112 - otherwise the new lamp will rapidly fail in a similar manner.; Fusing of Discharge Studio and Theatre Lamps
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 110 Pins - 350°C maximum Above this figure the plating on the pins may lose adhesion and the contact will deteriorate. Such deterioration may form local hot spots which rapidly worsen and may result in arcing and irrepara...
Page 113 - Spectral distribution of luminous flux (lumens) for
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 111 Spectral distribution of luminous flux (lumens) for CSI discharge lamps 4 3 2 1 400 500 600 700 800 wavelength (nm) mW / 5nm / W Spectral distribution of luminous flux (lumens) for CID discharge lamps 2.5 2.0 1.5 1.0 ...
Page 114 - Lamp type; Index
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 112 Lamp type page Ou tsid e B ro ad ca st Dis co Th ea tre / S tag e Ph oto gra ph ic M icro gra ph ic Au dio vis ua l TV / F ilm / S tud io PAR lamps by order code 25PAR36 7 • 25PAR36/NSP 7 • 25PAR36/WFL 7 • 25PAR36/VWF...
Page 115 - DWE
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 113 Lamp type page 300PAR56/NSP 12 • 300PAR56/MFL 12 • 300PAR56/WFL 12 • 500PAR64/NSP 17 • 500PAR64/MFL 17 • Q500PAR56/NSP 12 • Q500PAR56/MFL 12 • Q500PAR56/WFL 12 • Q500PAR64/VNSP 15 • Q500PAR64/NSP 15 • Q500PAR64/MFL 15...
Page 127 - SINGLE ENDED MINIS; CID
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 125 Lamp type page CMH SINGLE ENDED MINIS 64 • SINGLE ENDED 64 • PAR 65 • DOUBLE ENDED 65 • Discharge lampsCSI 99-0201 67 • 99-0221 68 • 99-1222 69 • 99-1422 69 • CID 99-0211 70 • 99-0222 71 • 99-0415 71 • • 99-0431 72 • ...
Page 135 - GE Lighting World addresses
G E L I G H T I N G - E N T E R TA I N M E N T L I G H T I N G C ATA L O G U E 133 ARGENTINA GE Iluminacion S.A.Av. San Martin S/N Esquina 25 de Mayo1618-El TalarTigre, Pcia de Buenos AiresTel: (54) 11 4736 6600Fax: (54) 11 4736 6616 AUSTRALIA GE Lighting Australia Ltd.125-127 Long StreetSmithfield,...
Page 144 - E N T E R T A I N M E N T L I G H T I N G; • S T A G E • S T U D I O • D I S C O • P H O T O G R A P H I C; GE Lighting
GE Lighting We bring good things to life SS 03/2000 TIMOTHY GUY DESIGN and General Electric are both registered trade marks of the General Electric Company, USA © General Electric Company (USA) 2000 www.GELighting.com E N T E R T A I N M E N T L I G H T I N G • S T A G E • S T U D I O • D I S C O • ...