GE JGB700SEJ4SS - Installation Manual

GE JGB700SEJ4SS

GE JGB700SEJ4SS – Installation Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
Page: / 2
Loading the manual

DIMENSIONS AND
CLEARANCES

Provide adequate clearances between the
range and adjacent combustible surfaces.
These dimensions must be met for safe use
of your range.

Allow 30” (76.2 cm) minimum clearance
between burners and bottom of unprotected
wood or metal cabinet, or allow a 24” (61 cm)
minimum when bottom of wood or metal cabinet
is protected by no less than 1/4” (6.4 mm) thick
flame-retardant millboard covered with no less

than No. 28 MSG sheet metal (.015” [.38 mm]
thick), .015” (.38 mm) thick stainless steel, .025”
(0.64 mm) aluminum or .020” (0.5 mm) copper.

Installation of a listed microwave oven or
cooking appliance over the cooktop shall
conform to the installation instructions packed
with that appliance.

For island installation, maintain 2-1/2”
minimum from cutout to back edge of
countertop and 3” minimum from cutout to side
edges of countertop.

CONNECTOR HOOKUP

TOOLS YOU WILL NEED

MATERIALS YOU MAY NEED

Ŷ

Gas line shut-off valve

Ŷ

Pipe joint sealant or UL-approved pipe thread
tape with Teflon* that resists action of natural
and propane gases

Ŷ

Flexible metal appliance connector (1/2” I.D.).
A 5-foot length is recommended for ease of
installation but other lengths are acceptable.
Never use an old connector when installing a
new range.

Ŷ

Flare union adapter for connection to gas
supply line (3/4” or 1/2” NPT x 1/2” I.D.)

Ŷ

Flare union adapter for connection to pressure
regulator on range (1/2” NPT x 1/2” I.D.)

Ŷ

Liquid leak detector or soapy water.

*Teflon: Registered trademark of DuPont

Flat-blade

screwdriver

Pipe wrenches (2)

(one for backup)

Phillips

screwdriver

Open-end or

adjustable wrench

Pencil and ruler

Level

Drill, awl or nail

Pressure
regulator

Gas Flow into Range

Gas Flow into Range

Flex
connector
(6 ft. max.)

Adapter

Installer: Inform the consumer of the location of the gas shut-off valve.

1/2” or 3/4”

Gas pipe

Adapter

Gas
shut-off
valve

Pressure
regulator

Elbow

Elbow

Nipple

Union

Nipple

Gas
shut-off
valve

1/2” or 3/4”

Gas pipe

Flexible

Option

Rigid Pipe

Option

IN THE COMMONWEALTH
OF MASSACHUSETTS

Ŷ

This product must be installed by a licensed
plumber or gas fitter.

Ŷ

When using ball type gas shut-off valves,
they shall be the T-handle type.

Ŷ

A flexible gas connector, when used, must
not exceed 5 feet.

BEFORE YOU BEGIN
IMPORTANT —

Save these

instructions for local inspector’s use.

IMPORTANT

Observe all governing

codes and ordinances.

IMPORTANT

Remove all packing

material and literature from oven before
connecting gas and electrical supply to range.

IMPORTANT

To avoid damage

to your cabinets, check with your builder
or cabinet supplier to make sure that the
materials used will not discolor, delaminate
or sustain other damage. This oven has been
designed in accordance with the requirements
of UL and CSA International and complies
with the maximum allowable wood cabinet
temperatures of 194°F (90°C).

Note to Installer

– Be sure to leave these

instructions with consumer.

Note to consumer

– Keep these instructions

for future reference.

Servicer

– The electrical diagram is in an

envelope attached to the back of the range.

Proper installation is the responsibility of the
installer.

Product failure due to improper installation is
not covered under warranty.

Before installing your range on linoleum or
any other synthetic floor covering, make sure
the floor covering can withstand 180°F without
shrinking, warping or discoloring. Do not install
the range over carpeting unless a sheet of
1/4” thick plywood or similar insulator is placed
between the range and carpeting.

Mobile Home - Additional Installation
Requirements

The installation of this range must conform
to the Manufactured Home Construction and
Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile
Home Construction and Saftey, Title 24,
HUD Part 280). When such standard is not
applicable, use the Standard for Manufactured
Home Installations, ANSI A225.1/NFPA 501A
or with local codes.

In Canada, the installation of this range must
conform with the current standards CAN/CSA-
A240-latest edition, or with local codes.

When this range is installed in a mobile
home, it must be secured to the floor during
transit. Any method of securing the range
is adequate as long as it conforms to the
standards listed above.

WARNING

FIRE OR EXPLOSION
HAZARD

If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or death.

Installation must be performed by a qualified
installer.

Read these instructions completely and carefully.

Installation of this range must conform with
local codes, or in the absence of local codes,
with the National Fuel Gas Code, ANSI Z223.1/
NFPA.54, latest edition. In Canada, installation
must conform with the current Natural Gas
Installation Code, CAN/CGA-B149.1 or the
current Propane Installation Code, CAN/CGA-
B149.2, and with local codes where applicable.
This range has been design-certified by
CSA International according to ANSI Z21.1,

latest edition and Canadian Gas Association
according to CAN/CGA-1.1 latest edition.

When installing a gas appliance the use of
old flexible connectors can cause gas leaks
and personal injury. Always use a

NEW

flexible connector.

Leak testing of the appliance shall be conducted
according to the manufacturer instructions.

The range must be electrically grounded in
accordance with local codes or, in the absence
of local codes, in accordance with the National
Electrical Code (ANSI/NFPA 70, latest edition).
In Canada, electrical grounding must be
in accordance with the current CSA C22.1
Canadian Electrical Code Part 1 and/or local
codes. See Electrical Connections in this section.

Do not install this product with an air curtain
hood or other range hood that operates by
blowing air down on the cooktop. This airflow
may interfere with operation of the gas burners
resulting in fire or explosion hazard.

1

GAS SUPPLY

WARNING

Fire Hazard: Do not use

a flame to check for gas leaks.

WARNING

Explosion Hazard: Do

not exceed 25 ft-lbs of torque when making
gas line connections. Overtightening may
crack the pressure regulator resulting in fire
or explosion hazard.
Gas Pressure Regulator

You must use the gas pressure regulator supplied
with this range. For proper operations the inlet
pressure to the regulator should be as follows:

Natural Gas:

Minimum pressure: 6” of Water Column
Maximum pressure: 13” of Water Column

Propane Gas:

Minimum pressure: 11” of Water Column
Maximum pressure: 13” of Water Column
If you are not sure about the inlet pressure
contact local gas supplier.

Shut off the main gas supply valve before
disconnecting the old range and leave it off
until the new hook-up has been completed.
Don’t forget to relight the pilot on other gas
appliances when you turn the gas back on.

Because hard piping restricts movement of
the range, the use of a CSA International-
certified flexible metal appliance connector is
recommended unless local codes require a
hard-piped connection.
If the hard piping method is used, you must
carefully align the pipe; the range cannot be
moved after the connection is made.

To prevent gas leaks, put pipe joint compound
on, or wrap pipe thread tape with Teflon*
around, all male (external) pipe threads.
A. Install a manual shut-off valve in the gas line

in an easily accessed location outside of the
range. Make sure everyone operating the
range knows where and how to shut off the
gas supply to the range.

B. Install male 1/2” flare union adapter to the

1/2” NPT internal thread at inlet of regulator.
Use a backup wrench on the regulator fitting
to avoid damage.

C. Install male 1/2” or 3/4” flare union adapter

to the NPT internal thread of the manual
shut-off valve, taking care to back-up the
shut-off valve to keep it from turning.

D. Connect flexible metal appliance connector

to the adapter on the range. Position range
to permit connection at the shut-off valve.

E. When all connections have been made, make

sure all range controls are in the off position
and turn on the main gas supply valve.
Use a liquid leak detector at all joints and
connections to check for leaks in the system.

When using pressures greater than 1/2 psig
to pressure test the gas supply system of the
residence, disconnect the range and individual
shut-off valve from the gas supply piping. When
using pressures of 1/2 psig or less to pressure
test the gas supply system, simply isolate the
range from the gas supply system by closing
the individual shut-off valve.
When checking for proper operation of the
regulator, the inlet pressure must be at least 1”
greater than the operating (manifold) pressure
as given on rating label of product.
*Teflon: Registered trademark of DuPont

2

ELECTRICAL

CONNECTIONS

WARNING

Shock Hazard: This

appliance must be properly grounded.
Failure to do so can result in electric shock.

Electrical Requirements -

120-volt, 60 Hertz,

properly grounded dedicated circuit protected
by a 15-amp or 20-amp circuit breaker or time
delay fuse.

NOTE:

Use of automatic, wireless, or wired

external switches that shut off power to the
appliance are not recommended for this product.

Grounding

The power cord of this appliance is equipped
with a three-prong (grounding) plug which plugs
into a standard three-prong grounding wall
receptacle to minimize the possibility of electric
shock hazard from this appliance.

The customer should have the wall receptacle
and circuit checked by a qualified electrician to
make sure the receptacle is properly grounded.

Where a standard two-prong wall receptacle is
encountered, it is the personal responsibility and
obligation of the customer to have it replaced with
a properly grounded three-prong wall receptacle.

DO NOT, UNDER ANY CIRCUMSTANCES,
CUT OR REMOVE THE THIRD (GROUND)
PRONG FROM THE POWER CORD. DO
NOT USE AN ADAPTER. DO NOT USE AN
EXTENSION CORD.

Ground Fault Circuit Interrupters (GFCI’s) are
not required or recommended for gas range
receptacles. Performance of the range will not be
affected if operated on a GFCI-protected circuit
but occasional nuisance tripping of the GFCI
breaker is possible.

4

CHECK SURFACE

BURNERS

Push and turn knob to LITE position. You
will hear a

clicking

sound indicating proper

operation of the spark module. Once the air
has been purged from the supply lines, burners
should light within 4 seconds. After burner
lights, rotate knob out of the LITE position.
Try each burner in succession until all burners
have been checked.

Quality of Flames

The flame quality of the burners needs to be
determined visually.

If burner flames look like (A), call for service.
Normal burner flames should look like (B) or
(C), depending on the type of gas you use

With propane gas, some yellow tipping on outer
cones is normal.

FOR YOUR SAFETY:

WARNING

Before beginning

the installation, switch power off at
service panel and lock the service
disconnecting means to prevent power
from being switched on accidentally.
When the service disconnecting
means cannot be locked, securely
fasten a prominent warning device,
such as a tag, to the service panel.

If you did not receive an anti-tip bracket with your
purchase, call 1.800.626.8774 to receive one at
no cost. (In Canada, call 1.800.561.3344.) For
installation instructions of the bracket,
visit: www.GEAppliances.com.
(In Canada, www.GEAppliances.ca.)

Anti-Tip Bracket

Kit Included

Ensure proper
ground exists
before use

WHEN ALL HOOKUPS ARE
COMPLETED

Make sure all controls are left in the off
position. Make sure the flow of combustion and
ventilation air to the range is unobstructed.

Check that all packing materials and tape
have been removed. This will include tape on
metal panel under control knobs (if applicable),
adhesive tape, wire ties, cardboard and
protective plastic. Failure to remove these
materials could result in damage to the
appliance once the appliance has been turned
on and surfaces have heated.

DIMENSIONS AND CLEARANCES (CONT.)

GAS PIPE AND ELECTRICAL OUTLET LOCATIONS

INSTALLATION INSTRUCTION

31-10998-3 06-17 GEA

JGBS62, JGB645, JGBS66, JGB660, JGB700

5

CHECK BAKE AND

BROIL BURNERS

Ŷ6HW%DNHIXQFWLRQWRƒ)%XUQHUVKRXOG

light in 30 to 90 seconds.

Ŷ&KHFNEURLOEXUQHUXVLQJWKHVDPH

method as the bake burner.

• A child or adult can tip the range and be killed.

• Install the anti-tip bracket to the wall or floor.

• Engage the range to the anti-tip bracket by sliding the
range back such that the foot is engaged.

• Re-engage the anti-tip bracket if the range is moved.

• Failure to do so can result in death or serious burns
to children or adults.

Tip-Over Hazard

WARNING

Installation Instructions
Range

Questions? Call GE Appliances at 1.800.GE.CARES (1.800.432.2737) or visit
www.GEAppliances.com. In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca.

CONVERTING TO PROPANE
GAS (OR CONVERTING
BACK TO NATURAL GAS
FROM PROPANE)

This range leaves the factory set for use with
natural gas. If you want to convert to propane
gas, the conversion must be performed by a
qualified propane gas installer.

The conversion orifices and instructions can
be found on back of the range.

Keep these instructions and all orifices in
case you want to convert back to natural gas.

INSTALLATION AT HIGH ALTITUDE

Over 6000ft, product configured for natural gas or propane requires installation of kit
WB49X2541. Follow the instructions included with the kit.

Rear of Range

Orifice Strip
(location
may vary)

Spirit level

X

Y

Minimum to
cabinets on
either side
of the range

30”

30”
Minimum

15”

3”
Minimum
clearance to
right wall

Maximum

depth for

cabinets above

countertops

Front edge
of the range
side panel
forward from
cabinet

0”
To cabinets
below cooktop
and at the
range back

1/4”

6”

Minimum

clearance

to left wall

0”

18”

To cabinets

below

cooktop

and at the

range back

Recommended area for 120V

outlet on rear wall and area for

through-the-wall

connection of

pipe stub and shut-off valve.

Recommended area

for

through-the-floor

connection of pipe stub

and shut-off valve.

CAUTION

To prevent

drafts from affecting burner
operation, seal all openings
in floor under appliance and
behind appliance wall.

(C) Soft blue flames—

Normal for natural gas

(B) Yellow tips on outer

cones—

Normal for propane gas

(A) Yellow flames—

Call for service

6

INSTALL AND CHECK

ANTI-TIP DEVICE

WARNING

Never completely

remove the leveling leg as the range will not
be secured to the anti-tip device properly.

Follow instructions supplied with ANTI-TIP
bracket.

Anti-Tip Bracket

Kit Included

7

LEVEL THE RANGE

WARNING

Never completely

remove the leveling leg as the range will not
be secured to the anti-tip device properly.

A.

Plug in the unit.

B.

Measure the height of your countertop at the

rear of the opening (X).

C.

Adjust two rear leveling legs so that the rear

of cooktop is at the same height or higher
than the counter (Y).

D.

Slide unit into place.

E.

Install oven shelves in the oven and position

the range where it will be installed.

F.

Check for levelness by placing a spirit

level on one of the oven shelves. Take two
readings—with the level placed diagonally
first in one direction and then the other.

G.

Adjust front leveling legs until the range is

level.

H.

Look under the unit and verify that the rear

leg is fully engaged with the anti-tip device. If
not, remove the unit and adjust the height of
the rear leg so that it is properly engaged.

3

SURFACE BURNERS

WARNING

Fire or Explosion Hazard:

Do not operate the burner without all burner
parts in place.

A.

Burners -

Place surface burners into

corresponding positions on cooktop.

B.

Caps -

Place caps on proper size burner.

C.

Single Grates -

Place the oval (center)

head/cap assembly over the electrode on
the cooktop.

Left

Grate

Right
Grate

Center

Grate or Griddle

or

Front right burner

Electrode

Electrode

Hole

Cap

Burner

Cap

46 1/4"

28 3/4"

w/ handle

26 1/4"

w/o handle

30"

36 1/4" ± 1/4"

11 1/4"

NOTE:

Cooktop must be

at or above counter.

Grate

Cooktop

Counter

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
GE
Model
JGB700SEJ4SS
Document type
Installation Manual
Language(s)
English
Pages
2
File size
744.2 KB
Format
PDF

Other Manuals for GE JGB700SEJ4SS

Ask a question

Up to 3 photos. Max 5 MB each. Formats: JPG, JPEG, PNG, WebP.