A user manual for standalone electric ranges explains how to safely install them, covering electrical setup–including 3-wire or 4-wire wiring, power cord installation, and leveling. The guide also addresses key topics like safety precautions, required tools, and compliance verification through diagrams and checklists.

1 Page 1
2 Page 2
Page: / 2
Loading the manual
Page 1

Installation Instructions
Free-Standing Electric Ranges

Questions? Call 1.800.GE.CARES (1.800.432.2737) or visit www.GEAppliances.com

In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca

BEFORE YOU BEGIN

Read these instructions completely and

carefully.

® IMPORTANT — sove these instructions

for local inspector's use.

® IMPORTANT — observe all

° Proper installation is the responsibility of the

governing codes and ordinances.

.

.

.

* Product failure due to improper installation is

e Note to Installer - Be sure to leave these

not covered under warrant

instructions with consumer.

y:

e

Note to consumer - Keep these
instructions for future reference.

Skill level - Installation of this appliance

requires a qualified installer or electrician.

FOR YOUR SAFETY:

PNA SIIMG

Tip-Over Hazard

%

y

« Achild or adult can tip the range and be killed.
¢ {install the anti-tip bracket to the wall or floor.
« Engage the range to the anti-tip bracket by sliding the

range back such that the foot is engaged.

* Re-engage the anti-tip bracket if the range is moved.
* Failure to do so can result in death or serious burns

to children or adults.

Anti-Tip Bracket

Kit Included

AWARNING = Before beginning

the installation, switch power off at service

panel and lock the service disconnecting

if you did not receive an anti-tip bracket with your purchase,

call 1.800.626.8774 to receive one at no cost. {In Canada,

means to prevent power from being

call 1.800.561.3344} For installation instructions of the bracket,

switched on accidentally. When the service

visit: www.GEAppliances.com. {In Canada, www.GEAppliances.ca)

disconnecting means cannot be locked,
securely fasten a prominent warning device,
such as a tag, to the service panel.

TOOLS YOU WILL NEED

Drill with 1/8” Bit

Tin Snips

Safety Glasses

Tape Measure

Adjustable Wrench

Pliers

(UL Listed 40 AMP)

Level

1/4” Nut Driver

4-Wire Cord 4 long OR

3-Wire Cord 4’ long

MATERIALS YOU MAY NEED

Squeeze Connector

(For Conduit

Installations Only)

[4] REMOVE PACKAGING MATERIALS: railure to remove packaging materials could

result in darnage to the appliance. Remove all packing parts from oven, racks, heating elements

[2] PREPARE THE OPENING (FOR INDOOR USE ONLY)

See illustrations for all rough-in and spacing dimensions. The range may be placed with 0”
clearance (flush) at the back wall and side walls of the cabinet.

SINGLE OVEN

DOUBLE OVEN

On models with baking
or warming drawers,

~S

electrical outlet must not

be in this area.

2

2

“

on

25%

|

Nae

ein

\

47%

Acceptable electrical outlet area.
Orient electrical receptacle so the

length is parallel to floor.

oe

* GE-branded models have control

panels 307” wide.

NOTE: Use a 4’ power cord to prevent interference

with the storage drawer. Power cords 4%’ to 6’ long

may have to be dressed to allow for proper drawer

closing.

MINIMUM DIMENSIONS BETWEEN COOKTOP,

WALLS AND ABOVE THE COOKTOP:

A. Make sure the wall covering, countertop, flooring

and cabinets around the range can withstand the

heat (up to 200°F) generated by the range.

B. Allow 30” minimum clearance between surface

units and bottom of unprotected wood or metal

cabinet, or allow a 24” minimum when bottom

of wood or metal cabinet is protected by no less

than 1/4’ thick flame retardant millboard covered

with not less than No 28 MSG sheet metal, (.015”),

.015” thick stainless steel, 024”
aluminum or .020” copper.

C. This appliance has been approved for 0” spacing to adjacent surfaces above the cooktop. However,

a 6” minimum spacing to surfaces less than 15” above the cooktop and adjacent
cabinet is recommended to reduce exposure to steam, grease splatter and heat.

To reduce the risk of burns or fire when reaching over hot surface elements, cabinet storage space

above the cooktop should be avoided. If cabinet storage space is to be provided above

the cooktop, the risk can be reduced by installing a range hood that projects at least 5” beyond
the front of the cabinets. Cabinets installed above the cooktop must be no deeper than 13”.

[3] ELECTRICAL REQUIREMENTS

A WARNING: this appliance must be properly grounded.

A WARNING: ali new constructions, mobile homes, recreational vehicles and installations where

local codes do not allow grounding through neutral, require a 4-conductor UL-listed range cord.

A WARNING: to prevent fire or shock, do not use an extension cord with this appliance.

A WARNING: To prevent shock, remove house fuse or open circuit breaker before
beginning installation.

We recommend you have the electrical wiring and hookup of your range connected by a qualified

electrician. After installation, have the electrician show you how to disconnect power from the range.

You must use a single-phase, 120/208 VAC or 120/240 VAC, 60 hertz electrical system. If you connect
to aluminum wiring, properly installed connectors approved for use with aluminum wiring must be

used.

Effective January 1, 1996, the National Electrical Code requires that new construction (not

existing] utilize a 4-conductor connection to an electric range. When installing an electric range
in new construction, mobile home, recreational vehicle, or an area where local codes prohibit
grounding through the neutral conductor, refer to the section on four-conductor branch circuit
connections.

Check with your local utilities for electrical codes which apply in your area. Failure to wire your oven
according to governing codes could result in a hazardous condition. If there are no local codes, your
oven must be wired and fused to meet the National Electrical Code, NFPA No.

70 - latest edition, available from the National Fire Protection Association.

This appliance must be supplied with the proper voltage and frequency, and connected to an

individual, properly grounded, 40 amp (minimum) branch circuit protected by a circuit breaker
or time-delay fuse.

Use only a 3-conductor or a 4-conductor UL-listed range cord. These cords may be provided with ring

terminals on wire and a strain relief device.

A range cord rated at 40 amps with 125/250 minimum volt range is required. A 50 amp range cord

is not recommended but if used, it should be marked for use with nominal 1%2 diameter connection
openings. Care should be taken to center the cable and strain relief within the

knockout hole to keep the edge from damaging the cable.

The rating plate is located on the oven frame or on the side of the drawer frame.

SINGLE OVEN

DOUBLE OVEN

Rating plate

and drawer. Also, remove protective film and labels on the outer door, cooktop and control panel.

[a] POWER CORD AND CONDUIT INSTALLATION

Remove wire cover (on the back of range) by removing screws using a 1/4” nut driver. You can

access the terminal block by either removing a terminal block cover {on some models} or the

wire cover. Do not discard these screws.

Back of range

Back of range

—

—

»

5 screws to

be

pe”

remove wire

Retaining

cover

tabs

et

Screw to

=

ra,

remove

cose

terminal

block cover

Wire cover

Terminal block cover

For power cord installations only

(see the next step if using conduit),
assemble the strain relief in the hole. Insert
the power cord through the strain relief
and tighten. Allow enough slack
to easily attach the cord terminals to
the terminal block. If tabs are present at
the end of the winged strain relief, they
can be removed for better fit.

For power cord and 1” conduit only, remove the
knockout ring (1%”) located on bracket directly
below the terminal block. To remove the
knockout, use a pair of pliers to bend the
knockout ring away from the bracket and

twist until ring is removed.

Terminal block

lappearance

NOTE: Do not install the power cord without a

may vary}

strain relief. The strain relief bracket MUST be

installed before

reinstalling the rear range wiring cover.

Knockout

:

.

ring in

Strain relief

bracket

.

Terminal

block

Knockout ring

removed

\

Power cord

[p]

For 3/4” conduit installations only, purchase a squeeze connector matching the diameter

of your conduit and assemble it in the hole. Insert the conduit through the squeeze connector
and tighten. Allow enough slack to easily attach the wires to the terminal block. NOTE: Do not install the
conduit without a squeeze connector. The squeeze connector MUST be installed before reinstalling

the rear range wiring cover.

Squeeze

connector

Terminal block

Conduit

:

os

Bracket

Proceed to step 5 or 6.

[5 | 3-WIRE INSTALLATION

A WARNING: The neutral or ground wire of the power cord must be connected

to the neutral terminal located in the center of the terminal block and the ground strap must connect the

neutral terminal to the ground plate. The power leads must be connected to the lower left and the lower right

terminals of the terminal block.

DO NOT remove the ground strap connection.

FOR POWER CORD INSTALLATION

A. Remove the 3 lower terminal screws from the terminal block.

B. Insert the 3 terminal screws through each power cord terminal ring and into the lower

terminals of the terminal block. Be certain that the center wire (white/neutral]

is connected to the center lower position of the terminal block.

C. Tighten screws securely into the terminal block.

FOR CONDUIT INSTALLATION

A. Loosen the 3 lower terminal screws on the terminal block. Strip wire to exposed tip about 5/8” long.

B. Insert the center (white/neutral] wire tip through the bottom center terminal block opening.

On certain models, the wire will need to be inserted through the ground strap opening
and then into the bottorn center block opening. Insert the two side bare wire tips into

the lower left and the lower right terminal block openings.

C. Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.. Do not over-tighten

the screws.

NOTE: ALUMINUM WIRING: Aluminum building wire may be used but it must be rated

for the correct amperage and voltage.

Power Cord

Conduit

Terminal block

Terminal

lappearance ——_p

block

may vary)

Neutral terminal

Ground strap

Ground

plate

PROCEED TO STEP 7.

08-11

GE

[6] 4-WIRE INSTALLATION

A. WARNING: the neutral wire of the supply circuit must be connected to the neutral terminal

located in the lower center of the terminal block. The power leads must be connected to the lower left and the

lower right terminals of the terminal block. The grounding lead must be connected to the frame of the range with

the ground plate and the green ground screw.

FOR POWER CORD INSTALLATION

A, Remove the 3 lower terminal screws from the terminal block. Remove the ground screw and ground

plate and retain them. Cut and ciscard the ground strap. DO NOT DISCARD

ANY SCREWS.

B. Insert the one ground screw into the power cord ground wire terminal ring, through the ground plate

and into the frame of the range.

C. Insert the 3 terrninal screws (removed earlier) through each power cord terminal ring and into the lower

terminals of the terminal block. Be certain that the center wire (white/neutrall is connected to the center lower

position of the terminal block. Tighten screws securely into the terminal block.

FOR CONDUIT INSTALLATION

A. Loosen the 3 lower terminal screws on the terminal block. Remove the ground screw and ground plate and

retain them. Cut and discard the ground strap. DO NOT DISCARD ANY SCREWS. Strip wire to exposed tip

about 5/8” long.

B. Insert the ground bare wire tip between the range frame and the ground plate (removed earlier}

and secure it in place with the ground screw (removed earlier). Insert the bare wire (white/neutral tio through

the bottorn center of the terminal block opening. Insert the two side bare wire tips into the lower left and the

lower right terrninal block openings.

C. Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs}. Do not over-tighten the screws.

NOTE: ALUMINUM WIRING: Aluminum building wire may be used but it must be rated

for the correct amperage and voltage.

After~Power Cord

Before-Power Cord and Conduit

Ground strap

Neutral

terminal

Ground plate
(grounding to

range]

ROUND!

strap

Neutral

terminal

Terminal

sh @leia

ate

block

Ha etl (grounding

ql

/

to range}

Wire rd

Ue

tips

\

[7] REPLACE THE WIRE COVER

Replace wire cover on range back by sliding its left edge under the retaining tabs and replace the

screws removed earlier. Make sure that no wires are pinched between cover and range back.

Back of range

ata ent

5 screws to

Screw to

ue

remove wire

remove

Retaining

cover

terminal

tabs

Tat block cover

Terminal

block cover

To reduce the risk of tipping the range, the

range must be secured by a properly installed

anti-tip bracket. See installation instructions

shipped with the bracket for complete details

before attempting to install.

%

Tip-Over Hazard

A

° Achild or adult can tip the range and be killed.
* Install the anti-tip bracket to the wall or floor.

:

* Engage the range to the anti-tip bracket by sliding the | To check if the bracket is installed and

range back such that the foot is engaged.

engaged properly, look underneath the range

* Re-engage the anti-tip bracket if the range is moved.

to see that the rear leveling leg is engaged

° Failure to do so can result in death or serious burns

in the bracket. On some models, the storage

to children or adults.

drawer or kick panel can be removed for

easier inspection. If visual inspection is not

possible, slide the range forward, confirm the anti-tip bracket is securely attached to the floor or wall, and

slide the range back so the leveling leg is under the anti-tip bracket. If the range is pulled from the wall for

any reason, always repeat this procedure to verify the range is properly secured by the anti-tip bracket

Never completely remove the leveling legs or the range will not be secured to the anti-tip bracket.

[9] LEVEL THE RANGE (CONT.)

Position cord so that it does not interfere with drawer.

i 2 Lower

Place drawer rail on guides. Push the drawer in until it stops.

range

Lift front of drawer and push in until the stops clear

the guides.

ies

a 4

[1]

Lower the front of the drawer and push in until it closes.

.

S

MODELS WITH BAKING, WARMING DRAWERS OR DOUBLE OVEN

re

Plug in the unit.

Measure the height of your countertop at the rear of the opening {x).

Adjust two rear leveling legs so that the rear of cooktop is at the same height

as the counter (Y).

Slide unit into place.

Install oven shelves in the oven and position the range where it will be installed.

El

ele]

el

ele!

Check for jevelness by placing a spirit level on one of the oven shelves.

Take two readings—with the level placed diagonally first in one direction

and then the other.

Adjust front leveling legs until the range is level.

e]

[9] LEVEL THE RANGE

A WARNING: never completely remove the leveling leg

as the range will not be secured to the anti-tip device properly.

MODELS WITH STORAGE DRAWER OR KICK PANELS

Plug in unit and slide into place. Pull drawer out until it stops.

Lift front of drawer until the stops clear the guide. Remove the drawer.

Install the oven shelves in the oven and position the range where

it will be installed.

Check for levelness by placing a spirit level on one of the oven shelves.

Spirit level

Take two readings—with the level placed diagonally first

in one direction and then the other.

The front leveling legs can be adjusted from the bottom

we &

and the rear legs can be adjusted from the top or the bottom.

Fle]

&)

eel]

Use an adjustable wrench to adjust the leveling legs until

the range is level.

FINAL INSTALLATION CHECKLIST

* Check to make sure the circuit breaker is closed (RESET) or the circuit fuses are replaced.
* Be sure power is in service to the building.
* Check that all packing materials and tape have been removed. This will include tape on metal panel under

control knobs (if applicable}, adhesive tape, wire ties, cardboard and protective plastic. Failure to remove

these materials could result in damage to the appliance once the appliance has been turned on and

surfaces have heated.

* Check that the door and drawer are parallel to each other and that both operate smoothly. If they

do not, see the Owner’s Manual for proper replacement.

* Check to make sure that the rear leveling leg is fully inserted into the Anti-Tip bracket and that the bracket

is securely installed.

OPERATION CHECKLIST

* Turn on one of the surface units to observe that the element glows within 60 seconds. Turn the unit

off when glow is detected. If the glow is not detected within the time limit, recheck the range wiring
connections. If change is required, retest again. If no change is required, have building wiring checked for

proper connections and voltage.

* Check that the Clock fon models so equipped) display is energized. If a series of horizontal red

lines appear in the display, disconnect power immediately. Recheck the range wiring connections.
if change is made to connections, retest again. If no change is required, have building wiring checked for
proper connections and voltage. It is recommended that the clock be changed if the red lines appear.

* Be sure all range controls are in the OFF position before leaving the range.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

Helpful for 3 of 3 readers

About this manual

Brand
GE
Model
JB650SF2SS
Document type
Installation Manual
Language(s)
English, Spanish
Pages
2
File size
1.5 MB
Format
PDF

Ask a question

Up to 3 photos. Max 5 MB each. Formats: JPG, JPEG, PNG, WebP.