GE GXULQ - Manual
GE GXULQ – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – CARTRIDGE SPECIFICATIONS; Performance Data –; Filtration System GXULQ Using Filter GXULQR; Installation Instructions; FILTER CARTRIDGE REPLACEMENT; INSTALLING THE SYSTEM; SELECT A LOCATION; Select a location for the system that is:; DISCONNECT COLD WATER SUPPLY; compression; When correctly installed, the label will face out.
- Page 3 – INSTALL TUBING; Pull out slightly on the tubing to ensure a good seal.; CUTTING THE TUBING; holes for easier installation.; INSTALL FAUCET ADAPTER
- Page 4 – INSTALL COMPRESSION FITTINGS; Overtightening will cause the tubing to; FINAL CHECK; Cut the Tubing; PARTS LIST; INSTALL THE BATTERIES
- Page 6 – de distribution locale est supérieure à 100 lb/po; Caractéristiques complètes; ne pas; MESURES DE SÉCURITÉ; PIÈCES FOURNIS; • Adaptateur de robinet 3/8; Instructions
- Page 7 – ÉTAPES DE L’INSTALLATION; Assurez-vous de laisser un espace minimum; Instructions d’Installation; Installation optionnelle; SPÉCIFICATIONS DE CARTOUCHE; Caractéristiques complètes –; Système de filtration GXULQ utilisant un filtre GXULQR; INSTALLATION DU SYSTÈME; EMPLACEMENT D’INSTALLATION; Sélectionnez un emplacement pour le système qui soit :; Après une installation correcte, l’étiquette doit être
- Page 8 – DÉCOUPE DU TUYAU; pieds de tuyau sont fournis.; COUPEZ L’ALIMENTATION EN EAU
- Page 9 – (extrémité fermée à l’opposé; INSTALLATION DES PILES
- Page 10 – LISTE DES PIÈCES; DERNIÈRE VÉRIFICATION
- Page 11 – Notes
- Page 12 – HERRAMIENTAS NECESARIAS; • Consulte con su departamento de obras públicas local; PARTES INCLUIDOS; • Adaptador para grifo de 3/8; INSTALACIÓN CORRECTA; Datos del desarrollo
- Page 13 – Instrucciones de instalación; ESPECIFICACIONES DEL CARTUCHO; Datos del desarrollo –; Sistema de Filtración GXULQ con Uso de Filtro GXULQR; INSTALACIÓN DEL SISTEMA; Instalación opcional; REEMPLAZO DEL CARTUCHO DEL FILTRO; PARA RETIRAR EL FILTRO:; Una vez instalado correctamente, la; ELIJA UNA UBICACIÓN; Elija para el sistema una ubicación donde esté:
- Page 14 – Instale el adaptador para grifo de 3/8; CORTE DE LA TUBERÍA
- Page 15 – INSTALACIÓN DE LA TUBERÍA; Un ajuste excesivo hará que la tubería; INSTALACIÓN DE PILAS
- Page 16 – CONTROL FINAL; Corte de la tubería
1
TOOLS YOU WILL NEED
Installation
Kitchen and Bath Main Faucet
Instructions
Filtration System – GXULQ/GNULQ
SAFETY PRECAUTIONS
• Check with your state and local public works
department for plumbing and sanitation codes.
You must follow these guidelines as you install
the Kitchen and Bath Main Faucet Filtration
System. Using a qualified installer is recommended.
• Be sure the water supply conforms with the
Performance Data
. If the water supply conditions are
unknown, contact your municipal water company.
WARNING
—
Do not use with water that is
microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system.
• It is highly recommended that a water shut-off valve
be placed directly upstream of your Kitchen and Bath
Main Faucet Filtration System.
PARTS INCLUDED
• Filter Cartridge
• Filter Head/Bracket
• 6 Feet of 3/8
″
Tubing
• 3/8
″
x 1/2
″
Faucet Adapter
• 3/8
″
Compression Hex Nut
• 3/8
″
Ferrule
• 3/8
″
Tube Insert
• Mounting Screws
• 1/2
″
Compression to 3/8
″
Adapter
• 7/16
″
Compression to 3/8
″
Adapter
Optional accessories are available (Visa, MasterCard or
Discover cards accepted) by visiting our Website at ge.com
or from Parts and Accessories, call 800.626.2002 (U.S.) or
800.663.6060 (Canada).
Adjustable Wrench
Utility Knife
Phillips-Head
Screwdriver
238C3375P001 49-50225-1 07-07 JR
Printed in China
PROPER INSTALLATION
This Kitchen and Bath Main Faucet Filtration System
must be properly installed and located in
accordance with the Installation Instructions before
it is used.
•
Check with your local public works department
for plumbing codes. You must follow their guides
as you install the Kitchen and Bath Main Faucet
Filtration System.
•
Use the Kitchen and Bath Main Faucet Filtration
Systemon a potable, safe-to-drink, home COLD
water supply only. The filter cartridge will not
purify water or make unsafe water safe to drink.
DO NOT use on HOT water (100°F max).
•
Protect the Kitchen and Bath Main Faucet
Filtration Systemand piping from freezing. Water
freezing in the system will damage it .
•
Your Kitchen and Bath Main Faucet Filtration
Systemwill withstand up to 100 psi water
pressure. If your house water supply pressure is
higher than 100 psi during the day (it may reach
higher levels at night), install a pressure reducing
valve before the system is installed.
• Do not install on
HOT WATER
. The temperature
of the water supply to the Kitchen and Bath Main
Faucet Filtration System must be between the
minimum of 40°F and the maximum of 100°F.
See the
Performance Data
section.
•
Do not
install the Kitchen and Bath Main Faucet
Filtration System using copper solder fittings.
The heat from the soldering process will damage
the unit .
WARNING
—
Discard all unused parts
and packaging material after installation. Small parts
remaining after installation could be a choke hazard.
•
Do not
install filter in an outside location or
anywhere it will be exposed to sunlight .
System is Tested and Certified by NSF International
against NSF/ANSI Standard 42 for the reduction of
Chlorine, Taste and Odor and Particulate Class I and
Standard 53 for the reduction of Turbidity.
Drill with 1/8
″
Drill Bit
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Was this manual helpful?
About this manual
- Brand
- GE
- Model
- GXULQ
- Document type
- Manual
- Language(s)
- English, Spanish, French
- Pages
- 16
- Format
Summary
HOT COLD IN OUT Optional installation STEP-BY-STEP INSTALLATION INSTRUCTIONS Installation OverviewNOTE: Be sure to allow a minimum space of 1 1 / 2 ″ –2 ″ under the system for removing the filter cartridge.If you have copper tubing with 3/8 ″ compression fittings, you’ll need to follow Step 3 Option...
INSTALL TUBING Push the tubing firmly into the collet on thefaucet adapter fitting until the pencil mark is pushed next to the collet . (If the tubing is removed, recut the end, measure, mark and reinsert .) Tubing must be fully inserted to avoid leaks.To remove tubing: Depress and hold the whitecol...
INSTALL COMPRESSION FITTINGS Take the remaining section of tubing, slide thecompression hex nut and 3/8 ″ ferrule (tapered end away from the compression nut) onto thetubing, and put in the tube insert . Fasten the assembly onto the cold water supplyvalve. Do not overtighten. NOTE: Overtightening wil...